FCC ID PDHGMRS-1535A
GMRS-1535A
by TTI Tech Co., Ltd.
Grantee Code: PDH Product Code: GMRS1535A
Latest application date: 2002-03-12
FCC ID Device Details
| FCC ID | PDHGMRS-1535A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PDH |
| Product Code | GMRS1535A |
| Applicant Business | TTI Tech Co., Ltd. 🇰🇷 |
| Related Domains | |
| Equipment Class | GMRS-1535A |
| Test Firm | Compliance Certification Services Inc |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 462.55-462.725 MHz | Original Equipment | 2002-03-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| CRN 22034 revised user manual with RF exposure statement | Users Manual | 2002-03-12 | PDF 114.2 KB |
| CRN 22174 revised user manual | Users Manual | 2002-03-12 | PDF 399.2 KB |
| Revised user manual to include RF exposure information | Users Manual | 2002-03-12 | PDF 105.4 KB |
| CRN 22034 Radio without shielding | Internal Photos | 2002-03-12 | PDF 192.9 KB |
| Internal Photos | Internal Photos | 2002-03-12 | PDF 1.8 MB |
| External Photos | External Photos | 2002-03-12 | PDF 905.6 KB |
| CRN 22034 Occupational Warning label | ID Label/Location Info | 2002-03-12 | PDF 20.2 KB |
| FCC ID LABEL | ID Label/Location Info | 2002-03-12 | PDF 111.7 KB |
| CRN 22174 revised product specification sheet | Operational Description | 2002-03-12 | PDF 121.4 KB |
| Setup Photos | Test Setup Photos | 2002-03-12 | PDF 58.7 KB |
| CRN 22174 revised test report | Test Report | 2002-03-12 | PDF 876.9 KB |
| FCC Part 95A test report | Test Report | 2002-03-12 | PDF 864.4 KB |
| SAR Test Report | RF Exposure Info | 2002-03-12 | PDF 2.2 MB |
| CRN 22174 manufacturer letter to declare the max output power | Cover Letter(s) | 2002-03-12 | PDF 47 KB |
| Request for confidentiality letter | Cover Letter(s) | 2002-03-12 | PDF 45 KB |
| Request to change company name | Cover Letter(s) | 2002-03-12 | PDF 45 KB |
| Request to update FCC Form 731 information | Cover Letter(s) | 2002-03-12 | PDF 52 KB |
| CRN 22034 Dipole calibration report 1of 2 | RF Exposure Info | 2002-03-12 | PDF 2.2 MB |
| CRN 22034 Dipole calibration report 2 of 2 | RF Exposure Info | 2002-03-12 | PDF 2.8 MB |
| CRN 22034 Probe calibration report 1 of 2 | RF Exposure Info | 2002-03-12 | PDF 2.6 MB |
| CRN 22034 Probe calibration report 2 of 2 | RF Exposure Info | 2002-03-12 | PDF 1.9 MB |
| Block Diagram Metadata only | Block Diagram | PDF 12.8 KB | |
| Schematic Diagram Metadata only | Schematics | PDF 246.6 KB | |
| Theory of Operation Metadata only | Operational Description | PDF 49.6 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 26.3 KB | |
| Tune Up procedure Metadata only | Parts List/Tune Up Info | PDF 21.3 KB |
Application Information
| Application ID | rdc4UpLhcBLEnYxV5tegHA== |
|---|---|
| Final Action Date | 2002-03-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017823113 |
| Model | GMRS-1535A |
| Frequency Range | 462.55-462.725 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Responsible Party | J. N. LEE, Manager, ntkim@ttikorea.co.kr |
| Agent | Steve Steve Steve, Compliance Certification Services, Scheng@ccsemc.com |
| Technical Contact | STEVE CHENG, COMPLIANCE CERTIFICATION SERVICES, SCHENG@CCSEMC.COM |
| Non-Technical Contact | CHRISTINE VU, COMPLIANCE CERTIFICATION SERVICES, CVU@CCSEMC.COM |
| Test Firm | Steve Cheng, Compliance Certification Services Inc, scheng@ccemc.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is listed is ERP, (2 W conducted at antenna terminal). This transmitter has been tested for SAR compliance in Push to Talk and body worn configurations. Body worn SAR compliance is limited to the specific belt clip tested for this filing. This device must operate at duty factors not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are Head: 1.99 W/kg; Body worn: 4.02 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| rdc4UpLhcBLEnYxV5tegHA== | 2002-03-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application rdc4UpLhcBLEnYxV5tegHA==
This application does not exist.
EAS Grant - Application rdc4UpLhcBLEnYxV5tegHA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TTI Tech Co., Ltd. Eundo Bldg. #402, 737-19, Banpo-1dong Seocho-ku, 137-041 South Korea |
Date of Grant: 03/12/2002 Application Dated: 12/11/2001 |
| Attention: J. N. LEE , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PDHGMRS-1535A |
| Name of Grantee: | TTI Tech Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95A | 462.55 - 462.725 | 1.069 | 0.0005 % | 10K9F3E | |
| 95A | 462.55 - 462.725 | 0.523 | 0.0005 % | 10K9F3E |
| Output is listed is ERP, (2 W conducted at antenna terminal). This transmitter has been tested for SAR compliance in Push to Talk and body worn configurations. Body worn SAR compliance is limited to the specific belt clip tested for this filing. This device must operate at duty factors not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are Head: 1.99 W/kg; Body worn: 4.02 W/kg. |
| Mail To: |
| STEVE CHENG, EMC MANAGER |
| COMPLIANCE CERTIFICATION SERVICES |
| 561F MONTEREY ROAD |
| MORGAN HILL, CA 95037 |