FCC ID PGVCP-X515
PDA
by CyberBank Corp
Grantee Code: PGV Product Code: CPX515
Latest application date: 2006-02-20
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.7-848.31 MHz | Original Equipment | 2006-02-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| users manual Metadata only | Users Manual | 2006-02-20 | PDF 160 KB |
| users manual 1 | Users Manual | 2006-02-20 | PDF 1.9 MB |
| users manual 2 | Users Manual | 2006-02-20 | PDF 2.3 MB |
| internal photos | Internal Photos | 2006-02-20 | PDF 1.4 MB |
| external photos | External Photos | 2006-02-20 | PDF 686.7 KB |
| label location | ID Label/Location Info | 2006-02-20 | PDF 108 KB |
| sar test setup photos | RF Exposure Info | 2006-02-20 | PDF 199.4 KB |
| test setup photos | Test Setup Photos | 2006-02-20 | PDF 453.1 KB |
| test report | Test Report | 2006-02-20 | PDF 1 MB |
| request for confidentiality | Cover Letter(s) | 2006-02-20 | PDF 48.1 KB |
| sar probe calibration | RF Exposure Info | 2006-02-20 | PDF 1.5 MB |
| sar report | RF Exposure Info | 2006-02-20 | PDF 636.2 KB |
| sar test plots | RF Exposure Info | 2006-02-20 | PDF 1.1 MB |
| sar validation | RF Exposure Info | 2006-02-20 | PDF 233.8 KB |
| block diagram Metadata only | Block Diagram | PDF 211.2 KB | |
| schematics Metadata only | Schematics | PDF 490.5 KB | |
| operational description Metadata only | Operational Description | PDF 90.5 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 591.2 KB | |
| tune up info Metadata only | Parts List/Tune Up Info | PDF 104.6 KB |
Application Information
| Application ID | mfKFaa0OJMtnhHQDyes94A== |
|---|---|
| Final Action Date | 2006-02-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006206072 |
| Model | CP-X515 |
| Frequency Range | 824.7-848.31 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | PDA |
| Responsible Party | Russel Kim, R & D Manager, RUSSEL@CB.CO.KR |
| Test Firm | Ahn Chulho, LTA Co.,Ltd, chahn@ltalab.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is ERP. SAR compliance is limited to the specific configurations tested for in this filing. Body-worn operation is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn cooperating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Head: 0.62 W/kg; Body: 0.87 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| mfKFaa0OJMtnhHQDyes94A== | 2006-02-20 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application mfKFaa0OJMtnhHQDyes94A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 02/20/2006 Application Dated: 02/20/2006 |
| CyberBank Corp |
| 19th FL, Mirae-Bldg., 1306-6 |
| Seocho-Dong, Seocho-Gu |
| Seoul, 137-855 South Korea |
| Attention: Russel Kim , R & D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PGVCP-X515 |
| Name of Grantee: | CyberBank Corp |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | PDA |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.279 | 2.5 PM | 1M25F9W |
| Output power listed is ERP. SAR compliance is limited to the specific configurations tested for in this filing. Body-worn operation is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn cooperating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Head: 0.62 W/kg; Body: 0.87 W/kg. |
EAS Grant - Application mfKFaa0OJMtnhHQDyes94A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
CyberBank Corp 19th FL, Mirae-Bldg., 1306-6 Seocho-Dong, Seocho-Gu Seoul, 137-855 South Korea |
Date of Grant: 02/20/2006 Application Dated: 02/20/2006 |
| Attention: Russel Kim , R & D Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PGVCP-X515 |
| Name of Grantee: | CyberBank Corp |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | PDA |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.279 | 2.5 PM | 1M25F9W |
| Output power listed is ERP. SAR compliance is limited to the specific configurations tested for in this filing. Body-worn operation is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn cooperating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Head: 0.62 W/kg; Body: 0.87 W/kg. |
| Mail To: |