FCC ID PH7PX130

Fixed WLL Telephone (PCS CDMA)

by Axesstel Inc

Grantee Code: PH7   Product Code: PX130
Latest application date: 2007-01-26

FCC ID Device Details

FCC IDPH7PX130
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePH7
Product CodePX130
Applicant BusinessAxesstel Inc 🇺🇸
Related Domains axesstel.com
Equipment ClassFixed WLL Telephone (PCS CDMA)
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1851.25-1908.75 MHzOriginal Equipment2007-01-26

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2007-03-12PDF 813.3 KB
Internal PhotosInternal Photos2007-03-12PDF 363.6 KB
External PhotosExternal Photos2007-03-12PDF 173.9 KB
FCC ID Label and LocationID Label/Location Info2007-01-26PDF 71.8 KB
SAR Test Setup PhotosTest Setup Photos2007-03-12PDF 115.4 KB
Test Setup PhotosTest Setup Photos2007-03-12PDF 48.2 KB
Test PlotsTest Report2007-01-26PDF 86.6 KB
Test ReportTest Report2007-01-26PDF 132.9 KB
Attestation StatementsAttestation Statements2007-01-26PDF 16.3 KB
Cover LetterCover Letter(s)2007-01-26PDF 23.7 KB
Dipole CalibrationRF Exposure Info2007-01-26PDF 507 KB
Dipole ValidationRF Exposure Info2007-01-26PDF 221.2 KB
Probe CalibrationRF Exposure Info2007-01-26PDF 657.8 KB
SAR PlotsRF Exposure Info2007-01-26PDF 742.6 KB
SAR ReportRF Exposure Info2007-01-26PDF 838.6 KB

Application Information

Application IDh/BYP2RtBiw1oovNViZkSg==
Final Action Date2007-01-26
Application PurposeOriginal Equipment
Applicant FRN0006384788
ModelPX130
Frequency Range1851.25-1908.75 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionFixed WLL Telephone (PCS CDMA)
Responsible PartyEmily Chen, Program Manager, emilychen@axesstel.com , 858-625-2100
AgentRandy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB Emailrandy@pctestlab.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Short-Term Confidentiality Date03/12/2007
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is EIRP. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body: 0.896 W/kg.

Applications

Application IDDatePurpose
h/BYP2RtBiw1oovNViZkSg==2007-01-26Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1851.25-1908.75 MHz0.29900001.0000000000ppm1M28F9W24E

Grants

TCB Grant - Application h/BYP2RtBiw1oovNViZkSg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, Inc.
6660-B Dobbin Road
Columbia, MD 21045
Date of Grant: 01/26/2007

Application Dated: 01/26/2007
Axesstel Inc
6815 Flanders Drive Ste. 210
San Diego, CA 92121
 
Attention: Emily Chen , Program Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PH7PX130
Name of Grantee:  Axesstel Inc
Equipment Class: PCS Licensed Transmitter
Notes: Fixed WLL Telephone (PCS CDMA)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.299 1.0  PM 1M28F9W

Power output listed is EIRP. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body: 0.896 W/kg.

EAS Grant - Application h/BYP2RtBiw1oovNViZkSg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Axesstel Inc
6815 Flanders Drive Ste. 210
San Diego, CA 92121
United States
  Date of Grant: 01/26/2007

Application Dated: 01/26/2007
 
Attention: Emily Chen , Program Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PH7PX130
Name of Grantee:  Axesstel Inc
Equipment Class: PCS Licensed Transmitter
Notes: Fixed WLL Telephone (PCS CDMA)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.299 1.0  PM 1M28F9W

Power output listed is EIRP. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body: 0.896 W/kg.