FCC ID PH7TX240G
CDMA2000 Terminal
by Axesstel Inc
Grantee Code: PH7 Product Code: TX240G
Latest application date: 2009-09-20
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.7-848.31 MHz | Original Equipment | 2009-09-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2010-03-19 | PDF 1.5 MB |
| Internal photos | Internal Photos | 2010-03-19 | PDF 852.3 KB |
| External photos | External Photos | 2010-03-19 | PDF 388.9 KB |
| Label format and location | ID Label/Location Info | 2009-09-20 | PDF 338.7 KB |
| Test setup photos 1 of 2 | Test Setup Photos | 2010-03-19 | PDF 317.5 KB |
| Test setup photos 2 of 2 | Test Setup Photos | 2010-03-19 | PDF 307.6 KB |
| SAR test report | RF Exposure Info | 2009-09-20 | PDF 3.6 MB |
| Test report | Test Report | 2009-09-20 | PDF 706.4 KB |
| Authorization letter | Cover Letter(s) | 2009-09-20 | PDF 22.5 KB |
| Request for confidentiality | Cover Letter(s) | 2009-09-20 | PDF 20.9 KB |
Application Information
| Application ID | umDJj4pnj0w0Au5JtSTJqw== |
|---|---|
| Final Action Date | 2009-09-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006384788 |
| Model | TX240G |
| Frequency Range | 824.7-848.31 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | CDMA2000 Terminal |
| Responsible Party | Emily Chen, Program Manager, emilychen@axesstel.com |
| Test Firm | Kang Namwook, HCT Ltd., nwkang@hct.co.kr |
| TCB Email | mike.kuo@ccsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 03/19/2010 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is conducted. This device is approved for use in the wireless voice terminal described in this filing. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported Body SAR values are: Part 22: 1.33W/kg; Part 24: 0.664 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| umDJj4pnj0w0Au5JtSTJqw== | 2009-09-20 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application umDJj4pnj0w0Au5JtSTJqw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 09/20/2009 Application Dated: 09/20/2009 |
| Axesstel Inc |
| 6815 Flanders Drive Ste. 210 |
| San Diego, CA 92121 |
| Attention: Emily Chen , Program Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PH7TX240G |
| Name of Grantee: | Axesstel Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | CDMA2000 Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 | 22H | 824.7 - 848.31 | 0.281 | 2.5 PM | 1M28F9W |
| 28 | 24E | 1851.25 - 1908.75 | 0.258 | 2.5 PM | 1M28F9W |
| Output power is conducted. This device is approved for use in the wireless voice terminal described in this filing. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported Body SAR values are: Part 22: 1.33W/kg; Part 24: 0.664 W/kg. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
EAS Grant - Application umDJj4pnj0w0Au5JtSTJqw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Axesstel Inc 6815 Flanders Drive Ste. 210 San Diego, CA 92121 United States |
Date of Grant: 09/20/2009 Application Dated: 09/20/2009 |
| Attention: Emily Chen , Program Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PH7TX240G |
| Name of Grantee: | Axesstel Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | CDMA2000 Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 | 22H | 824.7 - 848.31 | 0.281 | 2.5 PM | 1M28F9W |
| 28 | 24E | 1851.25 - 1908.75 | 0.258 | 2.5 PM | 1M28F9W |
| Output power is conducted. This device is approved for use in the wireless voice terminal described in this filing. SAR compliance for operating configurations is based on a separation distance of 2.0 cm between the unit and the body of the user. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported Body SAR values are: Part 22: 1.33W/kg; Part 24: 0.664 W/kg. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| Mail To: |