FCC ID PIDMMAX5725

WiMAX base station

by Airspan Networks Inc

Grantee Code: PID   Product Code: MMAX5725
Latest application date: 2012-10-22

FCC ID Device Details

FCC IDPIDMMAX5725
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePID
Product CodeMMAX5725
Applicant BusinessAirspan Networks Inc 🇺🇸
Related Domains airspan.com
Equipment ClassWiMAX base station
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5726.75-5848.25 MHzOriginal Equipment2012-10-22

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2012-10-22PDF 1.3 MB
Int. photosInternal Photos2012-10-22PDF 886.9 KB
Ext. photosExternal Photos2012-10-22PDF 151.4 KB
LabelID Label/Location Info2012-10-22PDF 69.4 KB
test setup photosTest Setup Photos2012-10-22PDF 758.1 KB
test reportTest Report2012-10-22PDF 2.3 MB
Conf. letterCover Letter(s)2012-10-22PDF 16.6 KB
DoACover Letter(s)2012-10-22PDF 995.3 KB
RF expoRF Exposure Info2012-10-22PDF 12.6 KB

Application Information

Application IDiD+Ta6hkeUyA0lxFIG8JSg==
Final Action Date2012-10-22
Application PurposeOriginal Equipment
Applicant FRN0009320326
ModelMMAX5725
Frequency Range5726.75-5848.25 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWiMAX base station
Responsible PartyBrian Roberts, Product Specialist, zlevi@airspan.com , +1 561 893 8684
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com
Test FirmAlexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com , 972-4628-8001
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as in this filling must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
iD+Ta6hkeUyA0lxFIG8JSg==2012-10-22Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5726.75-5848.25 MHz0.0915CMO
5727.5-5847.5 MHz0.0915CMO
5728.5-5846.5 MHz0.0915CMO
5730-5845 MHz0.0915CMO

Grants

TCB Grant - Application iD+Ta6hkeUyA0lxFIG8JSg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 10/22/2012

Application Dated: 10/22/2012
Airspan Networks Inc
777 Yamato Rd
Suite 310
Boca Raton, FL 33431
 
Attention: Brian Roberts , Product Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PIDMMAX5725
Name of Grantee:  Airspan Networks Inc
Equipment Class: Digital Transmission System
Notes: WiMAX base station
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 5726.75  -  5848.25 0.09  
MO 15C 5727.5  -  5847.5 0.09  
MO 15C 5728.5  -  5846.5 0.09  
MO 15C 5730.0  -  5845.0 0.09  

Power output listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as in this filling must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application iD+Ta6hkeUyA0lxFIG8JSg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Airspan Networks Inc
777 Yamato Rd Suite 310
Boca Raton, FL 33431
United States
  Date of Grant: 10/22/2012

Application Dated: 10/22/2012
 
Attention: Brian Roberts , Product Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PIDMMAX5725
Name of Grantee:  Airspan Networks Inc
Equipment Class: Digital Transmission System
Notes: WiMAX base station
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 5726.75  -  5848.25 0.09  
MO 15C 5727.5  -  5847.5 0.09  
MO 15C 5728.5  -  5846.5 0.09  
MO 15C 5730.0  -  5845.0 0.09  

Power output listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as in this filling must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: