FCC ID PIDSYN2500

Base station of LTE fixed cellular system

by Airspan Networks Inc

Grantee Code: PID   Product Code: SYN2500
Latest application date: 2014-03-26

FCC ID Device Details

FCC IDPIDSYN2500
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePID
Product CodeSYN2500
Applicant BusinessAirspan Networks Inc 🇺🇸
Related Domains airspan.com
Equipment ClassBase station of LTE fixed cellular system
Test FirmHermon Laboratories

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2501-2685 MHzOriginal Equipment2014-03-26

Exhibits

DocumentTypeAvailableFile
User_manualUsers Manual2014-03-26PDF 1.5 MB
Internal_photosInternal Photos2014-09-22PDF 1.3 MB
External_photosExternal Photos2014-03-26PDF 351.9 KB
Label_ locationID Label/Location Info2014-03-26PDF 83.5 KB
Operational_descriptionOperational Description2014-03-26PDF 46.6 KB
Setup_photosTest Setup Photos2014-03-26PDF 444.6 KB
AIRRAD_FCC.25543_rev1Test Report2014-03-26PDF 1.3 MB
Antenna_11dBiCover Letter(s)2014-03-26PDF 754.6 KB
Antenna_17dBiCover Letter(s)2014-03-26PDF 129 KB
Antenna_18dBiCover Letter(s)2014-03-26PDF 107.2 KB
Authorization_letter_to_FCCCover Letter(s)2014-03-26PDF 995.3 KB
Cover_letterCover Letter(s)2014-03-26PDF 15.7 KB
DC_voltage_currentCover Letter(s)2014-03-26PDF 15.6 KB
Declaration_of_authorizationCover Letter(s)2014-03-26PDF 13.8 KB
RF_Env_evaluationCover Letter(s)2014-03-26PDF 52.7 KB
Request_confidentialityCover Letter(s)2014-03-26PDF 16.9 KB
Tune_up_procedureParts List/Tune Up Info2014-03-26PDF 16.8 KB
Schematics_FEM Metadata onlySchematicsPDF 235.7 KB
Schematics_SDR Metadata onlySchematicsPDF 1.6 MB
Parts_list Metadata onlyParts List/Tune Up InfoPDF 44.5 KB

Application Information

Application IDnBbW8pSEOxWMk0d++Jl15Q==
Final Action Date2014-03-26
Application PurposeOriginal Equipment
Applicant FRN0009320326
ModelSYN2500
Frequency Range2501-2685 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionBase station of LTE fixed cellular system
Responsible PartyGrant Pottash, Technical Services Director, zlevi@airspan.com , +1-561-443-1009
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., 972 4626 8440
Non-Technical ContactZion Levi, Airspan Networks Inc., 1 561 893 8686
Test FirmGeorge Shleimovich, Hermon Laboratories, george@hermonlabs.com , 972-4-6288001
TCB Emailcertification@telefication.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/22/2014
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOnly Professional Installation is allowed. Power output listed is conducted. Device supports MIMO (no beamforming) and SFBC mode. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
nBbW8pSEOxWMk0d++Jl15Q==2014-03-26Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2501-2685 MHz2.26350Hz10M0D7D27
2506-2680 MHz2.32350Hz20M0D7D27

Grants

TCB Grant - Application nBbW8pSEOxWMk0d++Jl15Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 03/26/2014

Application Dated: 03/25/2014
Airspan Networks Inc
777 Yamato Rd
Suite 310
Boca Raton, FL 33431
 
Attention: Grant Pottash , Technical Services Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PIDSYN2500
Name of Grantee:  Airspan Networks Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Base station of LTE fixed cellular system
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2501.0  -  2685.0 2.26 350.0  Hz 10M0D7D
27 2506.0  -  2680.0 2.32 350.0  Hz 20M0D7D

Only Professional Installation is allowed. Power output listed is conducted. Device supports MIMO (no beamforming) and SFBC mode. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application nBbW8pSEOxWMk0d++Jl15Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Airspan Networks Inc
777 Yamato Rd Suite 310
Boca Raton, FL 33431
United States
  Date of Grant: 03/26/2014

Application Dated: 03/25/2014
 
Attention: Grant Pottash , Technical Services Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PIDSYN2500
Name of Grantee:  Airspan Networks Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Base station of LTE fixed cellular system
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2501.0  -  2685.0 2.26 350.0  Hz 10M0D7D
27 2506.0  -  2680.0 2.32 350.0  Hz 20M0D7D

Only Professional Installation is allowed. Power output listed is conducted. Device supports MIMO (no beamforming) and SFBC mode. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: