FCC ID PIDUMAX3600

WiMAX base station

by Airspan Networks Inc

Grantee Code: PID   Product Code: UMAX3600
Latest application date: 2011-06-24

FCC ID Device Details

FCC IDPIDUMAX3600
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePID
Product CodeUMAX3600
Applicant BusinessAirspan Networks Inc 🇺🇸
Related Domains airspan.com
Equipment ClassWiMAX base station
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
3651.75-3698.25 MHzOriginal Equipment2011-06-24

Exhibits

DocumentTypeAvailableFile
Users manualUsers Manual2011-06-24PDF 1.5 MB
Internal photosInternal Photos2011-08-08PDF 1.1 MB
External photosExternal Photos2011-06-24PDF 148.4 KB
Label infoID Label/Location Info2011-06-24PDF 130.8 KB
Answers to FCC questionsOperational Description2011-06-24PDF 291.1 KB
Antenna 10.5 dBi data sheetOperational Description2011-06-24PDF 160.3 KB
Antenna 18 dBi data sheetOperational Description2011-06-24PDF 240.5 KB
Antenna 2 dBi data sheetOperational Description2011-06-24PDF 117.7 KB
DC voltage, current supplied to final amplifierOperational Description2011-06-24PDF 15.8 KB
Operational descriptionOperational Description2011-06-24PDF 47.4 KB
Test setup photosTest Setup Photos2011-06-24PDF 283.9 KB
Test reportTest Report2011-06-24PDF 1.2 MB
Authorization letterAttestation Statements2011-06-24PDF 59.2 KB
Unrestricted contention based protocol statementAttestation Statements2011-06-24PDF 84.5 KB
Cover letterCover Letter(s)2011-06-24PDF 76.2 KB
Request for confidentialityCover Letter(s)2011-06-24PDF 16.4 KB
RF exposure infoRF Exposure Info2011-06-24PDF 12.3 KB

Application Information

Application IDsQ2UpwWDyC5phhf6wFEy3g==
Final Action Date2011-06-24
Application PurposeOriginal Equipment
Applicant FRN0009320326
ModelUMAX3600
Frequency Range3651.75-3698.25 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionWiMAX base station
Responsible PartyBrian Roberts, Product Specialist, zlevi@airspan.com , +1 561 893 8684
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com , +972 4626 8440
Non-Technical ContactZion Levi, Airspan Networks Inc., zlevi@airspan.com , +1 561 893 8686
Test FirmAlexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com , 972-4628-8001
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/08/2011
Long-Term ConfidentialityYes
Grant DeferralNo
Grant Deferral Date12/01/2011
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is EIRP. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3).

Applications

Application IDDatePurpose
sQ2UpwWDyC5phhf6wFEy3g==2011-06-24Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
3651.75-3698.25 MHz3.2293Hz3M50D7D9
3652.5-3697.5 MHz4.5293Hz5M00D7D9
3653.5-3696.5 MHz6.4193Hz7M00D7D9
3655-3695 MHz6.4393Hz10M0D7D9

Grants

TCB Grant - Application sQ2UpwWDyC5phhf6wFEy3g==

This application does not exist.

EAS Grant - Application sQ2UpwWDyC5phhf6wFEy3g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Airspan Networks Inc
777 Yamato Rd Suite 310
Boca Raton, FL 33431
United States
  Date of Grant: 06/24/2011

Application Dated: 06/01/2011
 
Attention: Brian Roberts , Product Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PIDUMAX3600
Name of Grantee:  Airspan Networks Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX base station
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 3651.75  -  3698.25 3.22 93.0  Hz 3M50D7D
90 3652.5  -  3697.5 4.52 93.0  Hz 5M00D7D
90 3653.5  -  3696.5 6.41 93.0  Hz 7M00D7D
90 3655.0  -  3695.0 6.43 93.0  Hz 10M0D7D

Output power is EIRP. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3).



Mail To: