FCC ID PM3SD5200

RF Data Radio Transceiver

by Genex Telecom Co., Ltd.

Grantee Code: PM3   Product Code: SD5200
Latest application date: 2002-09-24

FCC ID Device Details

FCC IDPM3SD5200
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePM3
Product CodeSD5200
Applicant BusinessGenex Telecom Co., Ltd. 🇰🇷
Related Domains genexelec.co.kr
Equipment ClassRF Data Radio Transceiver
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-470 MHzOriginal Equipment2002-09-24

Exhibits

DocumentTypeAvailableFile
revised users manualUsers Manual2002-09-24PDF 86.9 KB
users manual Metadata onlyUsers Manual2002-09-24PDF 1,001.7 KB
internal componentInternal Photos2002-09-24PDF 201.4 KB
internal solderInternal Photos2002-09-24PDF 287.3 KB
external photo showing RF safety labelExternal Photos2002-09-24PDF 55 KB
external photosExternal Photos2002-09-24PDF 2.4 MB
label sample and locationID Label/Location Info2002-09-24PDF 947.6 KB
block diagramBlock Diagram2002-09-24PDF 78.2 KB
schematicsSchematics2002-09-24PDF 218.1 KB
operational descriptionOperational Description2002-09-24PDF 133.9 KB
test reportTest Report2002-09-24PDF 1.2 MB
MPE calculationRF Exposure Info2002-09-24PDF 6.7 KB
parts listParts List/Tune Up Info2002-09-24PDF 99.1 KB
tune up informationParts List/Tune Up Info2002-09-24PDF 84.9 KB

Application Information

Application IDXgg42K/ouBK1WdJCkLIKmA==
Final Action Date2002-09-24
Application PurposeOriginal Equipment
Applicant FRN0006143333
ModelSD5200
Frequency Range450-470 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionRF Data Radio Transceiver
Responsible PartyClark Cheon, Manager, clark@genexelec.co.kr , 82-2-803-9002
Test FirmSid Sanders, Timco Engineering, Inc., info@timcoengr.com , 352-472-5500
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 32cm from all persons and must not exceed an antenna gain of 0 dBd.

Applications

Application IDDatePurpose
Xgg42K/ouBK1WdJCkLIKmA==2002-09-24Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-470 MHz52.5ppm20K0F1D9
450-470 MHz22.5ppm11K2F1D90.21
450-470 MHz52.5ppm11K2F1D90.21
450-470 MHz22.5ppm20K0F1D9

Grants

TCB Grant - Application Xgg42K/ouBK1WdJCkLIKmA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/24/2002

Application Dated: 09/24/2002
Genex Telecom Co., Ltd.
6F Farmax Building, 796-27
Bangbae-Dong
Seocho-Gu, Seoul, 137-060
South Korea
 
Attention: Clark Cheon , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PM3SD5200
Name of Grantee:  Genex Telecom Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: RF Data Radio Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 5.0 2.5  PM 20K0F1D
90.210 450.0  -  470.0 2.0 2.5  PM 11K2F1D
90.210 450.0  -  470.0 5.0 2.5  PM 11K2F1D
90 450.0  -  470.0 2.0 2.5  PM 20K0F1D

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 32cm from all persons and must not exceed an antenna gain of 0 dBd.

EAS Grant - Application Xgg42K/ouBK1WdJCkLIKmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Genex Telecom Co., Ltd.
6F Farmax Building, 796-27 Bangbae-Dong
Seocho-Gu, Seoul, 137-060
South Korea
  Date of Grant: 09/24/2002

Application Dated: 09/24/2002
 
Attention: Clark Cheon , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PM3SD5200
Name of Grantee:  Genex Telecom Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: RF Data Radio Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 5.0 2.5  PM 20K0F1D
90.210 450.0  -  470.0 2.0 2.5  PM 11K2F1D
90.210 450.0  -  470.0 5.0 2.5  PM 11K2F1D
90 450.0  -  470.0 2.0 2.5  PM 20K0F1D

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 32cm from all persons and must not exceed an antenna gain of 0 dBd.



Mail To: