FCC ID PNQC-BPB

PCS Multi-Channel Amplifier Antenna

by Celletra Ltd.

Grantee Code: PNQ   Product Code: CBPB
Latest application date: 2001-08-24

FCC ID Device Details

FCC IDPNQC-BPB
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePNQ
Product CodeCBPB
Applicant BusinessCelletra Ltd. 🇮🇱
Related Domains celletra.com metlabs.com
Equipment ClassPCS Multi-Channel Amplifier Antenna
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1930-1990 MHzOriginal Equipment2001-08-24

Exhibits

DocumentTypeAvailableFile
RT for Revised ManualUsers Manual2001-08-24PDF 10.2 KB
Users ManualUsers Manual2001-08-24PDF 2.1 MB
Beamer ModuleExternal Photos2001-08-24PDF 378.6 KB
ICU PhotoExternal Photos2001-08-24PDF 127.9 KB
PCSExternal Photos2001-08-24PDF 136.8 KB
1519 and ID LabelID Label/Location Info2001-08-24PDF 124.5 KB
Label LocationID Label/Location Info2001-08-24PDF 125.6 KB
RT for Test ReportTest Report2001-08-24PDF 11.7 KB
Test ReportTest Report2001-08-24PDF 379.8 KB
Confidential RequestCover Letter(s)2001-08-24PDF 65.5 KB
Letter of AgencyCover Letter(s)2001-08-24PDF 10 KB
Internal Photos Metadata onlyInternal PhotosPDF 2.2 MB
Block Diagrams Metadata onlyBlock DiagramPDF 25.8 KB
DC to DC Supply Metadata onlySchematicsPDF 232.5 KB
PCS RX Schematics Metadata onlySchematicsPDF 3.3 MB
PCS TX Schematics Metadata onlySchematicsPDF 1.2 MB
Array and ICU Metadata onlyOperational DescriptionPDF 1.1 MB
Beamer specs Metadata onlyOperational DescriptionPDF 812 KB
Beamer Breakdown Tree Metadata onlyParts List/Tune Up InfoPDF 206.2 KB

Application Information

Application IDQkjWFdQkV+WZkHtcUqIKCQ==
Final Action Date2001-08-24
Application PurposeOriginal Equipment
Applicant FRN0005834759
ModelC-BPB
Frequency Range1930-1990 MHz
Equipment ClassAMP - Amplifier
Device DescriptionPCS Multi-Channel Amplifier Antenna
Responsible PartyGideon Argaman, GVP & CIO, celletra@celletra.com , 97249592522
AgentChris Chris Chris, MET Laboratories, Inc., charvey@metlabs.com , 410-354-3300
Technical ContactLiming Xu, MET Laboratories, Inc., lxu@metlabs.com , 410-354-3300
Non-Technical ContactMarianne Bosley, MET Laboratories, Inc., mbosley@metlabs.com , 410-354-3300
Test FirmJohn Mason, MET Laboratories, Inc., jmason@metlabs.com , 410-354-3300
TCB Emailcharvey@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis is a multi-carrier CDMA amplifier/repeater. The Power Output listed on this Grant is the combined conducted power of the four amplifiers. For multi-channel operation, the power per channel decreases proportionally as the number of channels is increased. The antenna(s) used for this transmitter must be fixed- mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307 (b)(3).

Applications

Application IDDatePurpose
QkjWFdQkV+WZkHtcUqIKCQ==2001-08-24Original Equipment

Equipment Authorization

FrequencyOutputEmissionRulesGrant Notes
1930-1990 MHz10.0000000F9W24BC

Grants

TCB Grant - Application QkjWFdQkV+WZkHtcUqIKCQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 08/24/2001

Application Dated: 08/24/2001
Celletra Ltd.
PO Box 106
Tavor Building 1
Yoqne'am Ilit, 20692
Israel
 
Attention: Gideon Argaman , GVP & CIO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PNQC-BPB
Name of Grantee:  Celletra Ltd.
Equipment Class: Amplifier
Notes: PCS Multi-Channel Amplifier Antenna
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24 1930.0  -  1990.0 10.0   F9W

This is a multi-carrier CDMA amplifier/repeater. The Power Output listed on this Grant is the combined conducted power of the four amplifiers. For multi-channel operation, the power per channel decreases proportionally as the number of channels is increased. The antenna(s) used for this transmitter must be fixed- mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307 (b)(3).

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application QkjWFdQkV+WZkHtcUqIKCQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Celletra Ltd.
PO Box 106 Tavor Building 1
Yoqne'am Ilit, 20692
Israel
  Date of Grant: 08/24/2001

Application Dated: 08/24/2001
 
Attention: Gideon Argaman , GVP & CIO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PNQC-BPB
Name of Grantee:  Celletra Ltd.
Equipment Class: Amplifier
Notes: PCS Multi-Channel Amplifier Antenna
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24 1930.0  -  1990.0 10.0   F9W

This is a multi-carrier CDMA amplifier/repeater. The Power Output listed on this Grant is the combined conducted power of the four amplifiers. For multi-channel operation, the power per channel decreases proportionally as the number of channels is increased. The antenna(s) used for this transmitter must be fixed- mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307 (b)(3).


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: