FCC ID POQWCE-100SU
CDMA Cellular Phone
by Modottel Co Ltd
Grantee Code: POQ Product Code: WCE100SU
Latest application date: 2003-08-08
FCC ID Device Details
| FCC ID | POQWCE-100SU |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | POQ |
| Product Code | WCE100SU |
| Applicant Business | Modottel Co Ltd 🇰🇷 |
| Related Domains | |
| Equipment Class | CDMA Cellular Phone |
| Test Firm | DT&C; Co., |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.7-848.31 MHz | Original Equipment | 2003-08-08 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| confirmation on users info page | Users Manual | 2003-08-08 | PDF 14.6 KB |
| users info page | Users Manual | 2003-08-08 | PDF 69.2 KB |
| users manual | Users Manual | 2003-08-08 | PDF 1.2 MB |
| warning page | Users Manual | 2003-08-08 | PDF 12.9 KB |
| int photos | Internal Photos | 2003-08-08 | PDF 802.3 KB |
| external photos | External Photos | 2003-08-08 | PDF 620.4 KB |
| label and location | ID Label/Location Info | 2003-08-08 | PDF 198.3 KB |
| test setup photos | RF Exposure Info | 2003-08-08 | PDF 561.3 KB |
| 21033c info | Test Report | 2003-08-08 | PDF 52.7 KB |
| EMC Test Plot | Test Report | 2003-08-08 | PDF 1.5 MB |
| EMC Test Report | Test Report | 2003-08-08 | PDF 275.6 KB |
| test report SAR | RF Exposure Info | 2003-08-08 | PDF 1.2 MB |
| Confidentiality Request | Cover Letter(s) | 2003-08-08 | PDF 88.5 KB |
| agency authorization | Cover Letter(s) | 2003-08-08 | PDF 339 KB |
| SAR Test Plots I | RF Exposure Info | 2003-08-08 | PDF 2.8 MB |
| SAR Test Plots II | RF Exposure Info | 2003-08-08 | PDF 3.1 MB |
| dipole validation | RF Exposure Info | 2003-08-08 | PDF 72.6 KB |
| probe calibration | RF Exposure Info | 2003-08-08 | PDF 1.4 MB |
Application Information
| Application ID | BUe+T37tV+MGXBewFz2jfA== |
|---|---|
| Final Action Date | 2003-08-08 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003775434 |
| Model | WCE-100SU |
| Frequency Range | 824.7-848.31 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | CDMA Cellular Phone |
| Responsible Party | David Oh, General Manager, david@modottel.com |
| Agent | Chris Chris Chris, MET Laboratories, Inc., tcbinfo@metlabs.com |
| Test Firm | Changho Lee, DT&C; Co.,, chlee@digitalemc.com |
| TCB Email | tcbinfo@metlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. Two versions of the enclosure are covered by this Grant. The highest reported SAR values are: Head: 1.46 W/kg; Body-worn: 0.69 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| BUe+T37tV+MGXBewFz2jfA== | 2003-08-08 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application BUe+T37tV+MGXBewFz2jfA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Electrical and Electronic Testing NA, Inc 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 08/08/2003 Application Dated: 08/08/2003 |
| Modottel Co Ltd |
| 2F. DongNam Bldg. 448-16 |
| Shingil-5Dong |
| YongDungPo-Ku, N/A South Korea |
| Attention: David Oh , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | POQWCE-100SU |
| Name of Grantee: | Modottel Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | CDMA Cellular Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22.901(d) | 824.7 - 848.31 | 0.333 | 2.5 PM | 1M25F9W |
| Output power is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. Two versions of the enclosure are covered by this Grant. The highest reported SAR values are: Head: 1.46 W/kg; Body-worn: 0.69 W/kg. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application BUe+T37tV+MGXBewFz2jfA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Modottel Co Ltd 2F. DongNam Bldg. 448-16 Shingil-5Dong YongDungPo-Ku, N/A South Korea |
Date of Grant: 08/08/2003 Application Dated: 08/08/2003 |
| Attention: David Oh , General Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | POQWCE-100SU |
| Name of Grantee: | Modottel Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | CDMA Cellular Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22.901(d) | 824.7 - 848.31 | 0.333 | 2.5 PM | 1M25F9W |
| Output power is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. Two versions of the enclosure are covered by this Grant. The highest reported SAR values are: Head: 1.46 W/kg; Body-worn: 0.69 W/kg. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |