FCC ID POTJ21A

Blood Pressure Monitor with BT

by Inventec Appliances Corp.

Grantee Code: POT   Product Code: J21A
Latest application date: 2023-01-16

FCC ID Device Details

FCC IDPOTJ21A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePOT
Product CodeJ21A
Applicant BusinessInventec Appliances Corp. 🇹🇼
Related Domains iac.com.tw
Equipment ClassBlood Pressure Monitor with BT
Test FirmEurofins E&E; Wireless Taiwan Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-01-16

Exhibits

DocumentTypeAvailableFile
User_ManualUsers Manual2023-07-11PDF 1.4 MB
internal photoInternal Photos2023-07-11PDF 4.1 MB
external photoExternal Photos2023-07-11PDF 2.4 MB
LabelID Label/Location Info2023-01-16PDF 437.8 KB
Test Setup PhotoTest Setup Photos2023-07-11PDF 511.8 KB
Test Setup PhotoTest Setup Photos2023-07-11PDF 449.5 KB
Tsup_SARTest Setup Photos2023-07-11PDF 301.2 KB
2211FE28_P15B_22-1686Test Report2023-01-16PDF 935.4 KB
2211FR11_AppendixATest Report2023-01-16PDF 679.2 KB
2211FR11_AppendixBTest Report2023-01-16PDF 2 MB
2211FR11_Part15.247 LE_22-1686Test Report2023-01-16PDF 1.1 MB
BLE_Antenna_LA31H2450-A35_0111Test Report2023-01-16PDF 447.1 KB
Confidentiality_Request_LetterCover Letter(s)2023-01-16PDF 614.6 KB
POACover Letter(s)2023-01-16PDF 638.4 KB
2211FS11-01_AppendixARF Exposure Info2023-01-16PDF 24.9 KB
2211FS11-01_AppendixBRF Exposure Info2023-01-16PDF 192.2 KB
2211FS11-01_AppendixCRF Exposure Info2023-01-16PDF 44.5 KB
2211FS11-01_AppendixDRF Exposure Info2023-01-16PDF 1.9 MB
2211FS11-01_SAR_22-1686RF Exposure Info2023-01-16PDF 1.1 MB
Block_Diagram Metadata onlyBlock DiagramPDF 274.6 KB
28-2.Schematic_KEYB_V1_20220427 Metadata onlySchematicsPDF 150.3 KB
28-2.Schematic_LEDB_V1_20220427 Metadata onlySchematicsPDF 148.3 KB
28-2.Schematic_MB_V2_20220829 Metadata onlySchematicsPDF 303.8 KB
28-2.Schematic_USBCB_V2_20220829 Metadata onlySchematicsPDF 166.7 KB
Operational_Decription Metadata onlyOperational DescriptionPDF 416.4 KB

Application Information

Application IDa0aThnrjseJQdXNUC/0X+g==
Final Action Date2023-01-16
Application PurposeOriginal Equipment
Applicant FRN0004363974
ModelJ21A
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBlood Pressure Monitor with BT
Responsible PartyDanny Tang, Senior Engineer, Tang.danny@iac.com.tw , 886-2-22999329
Test FirmFly LU, Eurofins E&E; Wireless Taiwan Co., Ltd, fly@atl-lab.com.tw , 886-3-2710188
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/11/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is maximum peak conducted.SAR compliance for body-worn operating configurations is at least 0 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory uses condition is < 0.1 W/kg at 1g, respectively.

Applications

Application IDDatePurpose
a0aThnrjseJQdXNUC/0X+g==2023-01-16Original Equipment
9zXf/wulx6QvXD3wb0r4ZA==2023-01-16Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
2402-2480 MHz0.001320015CCC

Grants

TCB Grant - Application a0aThnrjseJQdXNUC/0X+g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 01/16/2023

Application Dated: 01/11/2023
Inventec Appliances Corp.
37 Wugong 5th road, New Taipei Industrial Park,
Wugu District,
New Taipei City,
Taiwan
 
Attention: Danny Tang , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  POTJ21A
Name of Grantee:  Inventec Appliances Corp.
Equipment Class: Digital Transmission System
Notes: Blood Pressure Monitor with BT
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00132  

Output power is maximum peak conducted.
SAR compliance for body-worn operating configurations is at least 0 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory uses condition is < 0.1 W/kg at 1g, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application a0aThnrjseJQdXNUC/0X+g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Inventec Appliances Corp.
37 Wugong 5th road, New Taipei Industrial Park, Wugu District,
New Taipei City,
Taiwan
  Date of Grant: 01/16/2023

Application Dated: 01/11/2023
 
Attention: Danny Tang , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  POTJ21A
Name of Grantee:  Inventec Appliances Corp.
Equipment Class: Digital Transmission System
Notes: Blood Pressure Monitor with BT
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00132  

Output power is maximum peak conducted.
SAR compliance for body-worn operating configurations is at least 0 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory uses condition is < 0.1 W/kg at 1g, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 9zXf/wulx6QvXD3wb0r4ZA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 01/16/2023

Application Dated: 01/11/2023
Inventec Appliances Corp.
37 Wugong 5th road, New Taipei Industrial Park,
Wugu District,
New Taipei City,
Taiwan
 
Attention: Danny Tang , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  POTJ21A
Name of Grantee:  Inventec Appliances Corp.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Blood Pressure Monitor with BT
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 9zXf/wulx6QvXD3wb0r4ZA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Inventec Appliances Corp.
37 Wugong 5th road, New Taipei Industrial Park, Wugu District,
New Taipei City,
Taiwan
  Date of Grant: 01/16/2023

Application Dated: 01/11/2023
 
Attention: Danny Tang , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  POTJ21A
Name of Grantee:  Inventec Appliances Corp.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Blood Pressure Monitor with BT
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: