FCC ID PQC-4843D

1.4 GHz Cluster AP remote antenna

by Philips Medical Systems North America Co.

Grantee Code: PQC   Product Code: 4843D
Latest application date: 2017-05-18

Device Images

FCC ID Device Details

FCC IDPQC-4843D
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePQC
Product Code4843D
Applicant BusinessPhilips Medical Systems North America Co. 🇺🇸
Related Domains philips.com
Equipment Class1.4 GHz Cluster AP remote antenna
Test FirmCompliance Worldwide, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1395.9-1399.1 MHzOriginal Equipment2017-05-18

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-05-18PDF 1.7 MB
Internal PhotosInternal Photos2017-11-14PDF 445.7 KB
External PhotosExternal Photos2017-05-18PDF 571.2 KB
Label LocationID Label/Location Info2017-05-18PDF 148.4 KB
Label SampleID Label/Location Info2017-05-18PDF 152.7 KB
Test Setup PhotosTest Setup Photos2017-05-18PDF 751.9 KB
Test ReportTest Report2017-05-18PDF 2.3 MB
Confidentiality Request LetterCover Letter(s)2017-05-18PDF 48.8 KB
Letter of AngencyCover Letter(s)2017-05-18PDF 30.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 240.8 KB
Schematics Metadata onlySchematicsPDF 148.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 405.1 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 56.7 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 1.9 MB

Application Information

Application IDSmJ6q2XOkVwD1kHz1e19gQ==
Final Action Date2017-05-18
Application PurposeOriginal Equipment
Applicant FRN0017950635
Model4843D
Frequency Range1395.9-1399.1 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device Description1.4 GHz Cluster AP remote antenna
Responsible PartyDelroy Smith, Principal Scientist / Project Leader, delroy.smith@philips.com , + 1 978 659 3382
Test FirmMark McSweeney, Compliance Worldwide, Inc., mark@complianceworldwide.com , 603-887-3903
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/14/2017
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
SmJ6q2XOkVwD1kHz1e19gQ==2017-05-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1395.9-1399.1 MHz0.018320.001558%1M44L7D95H
1427.9-1431.1 MHz0.014390.001663%1M47L7D95H

Grants

TCB Grant - Application SmJ6q2XOkVwD1kHz1e19gQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 05/18/2017

Application Dated: 05/18/2017
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-4843D
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 1.4 GHz Cluster AP remote antenna
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95H 1395.9  -  1399.1 0.01832 0.001558  % 1M44L7D
95H 1427.9  -  1431.1 0.01439 0.001663  % 1M47L7D

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application SmJ6q2XOkVwD1kHz1e19gQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 05/18/2017

Application Dated: 05/18/2017
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-4843D
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 1.4 GHz Cluster AP remote antenna
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95H 1395.9  -  1399.1 0.01832 0.001558  % 1M44L7D
95H 1427.9  -  1431.1 0.01439 0.001663  % 1M47L7D

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.



Mail To: