FCC ID PQC-OBRTBV1
Wireless Transducer
by Philips Medical Systems North America Co.
Grantee Code: PQC Product Code: OBRTBV1
Latest application date: 2024-01-29
FCC ID Device Details
| FCC ID | PQC-OBRTBV1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PQC |
| Product Code | OBRTBV1 |
| Applicant Business | Philips Medical Systems North America Co. 🇺🇸 |
| Related Domains | |
| Equipment Class | Wireless Transducer |
| Test Firm | cetecom advanced GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 608.375-613.625 MHz | Class II permissive change or modification of presently authorized equipment | 2024-01-29 |
| 608.375-613.625 MHz | Class II permissive change or modification of presently authorized equipment | 2020-12-03 |
| 608.375-613.625 MHz | Class II permissive change or modification of presently authorized equipment | 2019-06-13 |
| 608.375-613.625 MHz | Original Equipment | 2013-07-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users_Manual | Users Manual | 2024-01-29 | PDF 4.3 MB |
| User Manual | Users Manual | 2014-01-07 | PDF 3.4 MB |
| Internal_Photos | Internal Photos | 2024-01-29 | PDF 654.2 KB |
| Internal Photos | Internal Photos | 2020-12-03 | PDF 643.3 KB |
| Internal Photos | Internal Photos | 2019-06-13 | PDF 684.9 KB |
| Internal Photos | Internal Photos | 2014-01-07 | PDF 1.7 MB |
| External_Photos | External Photos | 2024-01-29 | PDF 183.8 KB |
| External Photos | External Photos | 2020-12-03 | PDF 540.2 KB |
| External Photos | External Photos | 2019-06-13 | PDF 428.5 KB |
| External Photos | External Photos | 2014-01-07 | PDF 566.9 KB |
| Labels | ID Label/Location Info | 2013-07-11 | PDF 84.7 KB |
| Test_Setup_Photos | Test Setup Photos | 2024-01-29 | PDF 391.3 KB |
| Test Setup Photos | Test Setup Photos | 2020-12-03 | PDF 900.8 KB |
| Test Setup Photos | Test Setup Photos | 2014-01-07 | PDF 493.9 KB |
| Test_report_Other | Test Report | 2024-01-29 | PDF 1.8 MB |
| Test Report | Test Report | 2020-12-03 | PDF 2.4 MB |
| Test Report | Test Report | 2019-06-13 | PDF 1,019 KB |
| Test Report | Test Report | 2013-07-11 | PDF 1.1 MB |
| 2.911(d)(5) | Attestation Statements | 2024-01-29 | PDF 195.7 KB |
| 2.911(d)(7) | Attestation Statements | 2024-01-29 | PDF 90.4 KB |
| C2PCPC_Notification_Letter | Cover Letter(s) | 2024-01-29 | PDF 189.6 KB |
| C2PC_Request_Letter | Cover Letter(s) | 2024-01-29 | PDF 184.8 KB |
| Confidentiality_Request_Letter | Cover Letter(s) | 2024-01-29 | PDF 988.1 KB |
| KDB_Inquiry_729778 | Cover Letter(s) | 2024-01-29 | PDF 204 KB |
| Declaration RF Equality Avalon CL XDR | Cover Letter(s) | 2020-12-03 | PDF 207 KB |
| Request for Permissive Change Class II | Cover Letter(s) | 2020-12-03 | PDF 359.8 KB |
| FCC Confidentiality Request - permanent | Cover Letter(s) | 2019-06-13 | PDF 35.8 KB |
| Permissive change request letter | Cover Letter(s) | 2019-06-13 | PDF 143.4 KB |
| Confidentiality Request Letters | Cover Letter(s) | 2013-07-11 | PDF 674.1 KB |
| Declaration of electrically indentical products | Cover Letter(s) | 2013-07-11 | PDF 634.8 KB |
| Short term confidentiality request letter | Cover Letter(s) | 2013-07-11 | PDF 695.5 KB |
| RF_Exposure_Evaluation | RF Exposure Info | 2024-01-29 | PDF 262.8 KB |
| RF Exposure Info | RF Exposure Info | 2013-07-11 | PDF 140.7 KB |
| Schematics_-_Board Metadata only | Schematics | PDF 1.3 MB | |
| Schematics_-_Curcuit_Diagram Metadata only | Schematics | PDF 384.1 KB | |
| SW-change-description-confidential Metadata only | Operational Description | PDF 477.3 KB |
Application Information
| Application ID | N/TwZX20KxXK6R8wUZYUFA== |
|---|---|
| Final Action Date | 2024-01-29 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0017950635 |
| Model | OBRTBV1 |
| Frequency Range | 608.375-613.625 MHz |
| Equipment Class | TNT - Licensed Non-Broadcast Transmitter Worn on Body |
| Device Description | Wireless Transducer |
| Responsible Party | Delroy Smith, Principal Architect, delroy.smith@philips.com |
| Test Firm | Gerald Schmidt, cetecom advanced GmbH, gerald.schmidt@cetecomadvanced.com |
| TCB Email | TCB@ctcadvanced.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC (Class II Permissive Change): Changing oscillator in accordance with Notification 202109-001. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| N/TwZX20KxXK6R8wUZYUFA== | 2024-01-29 | Class II permissive change or modification of presently authorized equipment |
| 8NaUajfMT7ImZa9FThqhQw== | 2020-12-03 | Class II permissive change or modification of presently authorized equipment |
| y1c7/S+1mI5mR+k18N8nsQ== | 2019-06-13 | Class II permissive change or modification of presently authorized equipment |
| Nztyb0AWR8m+6KxMV+KJdQ== | 2013-07-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application y1c7/S+1mI5mR+k18N8nsQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 06/13/2019 Application Dated: 06/13/2019 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Fetal Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC to allow different channel selection procedures and improved procedure to avoid channel collisions. |
EAS Grant - Application y1c7/S+1mI5mR+k18N8nsQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 06/13/2019 Application Dated: 06/13/2019 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Fetal Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC to allow different channel selection procedures and improved procedure to avoid channel collisions. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CETECOM ICT Services GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 07/11/2013 Application Dated: 07/11/2013 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 111KF1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. |
EAS Grant - Application Nztyb0AWR8m+6KxMV+KJdQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 07/11/2013 Application Dated: 07/11/2013 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 111KF1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
cetecom advanced GmbH Untertuerkheimer Strasse 6-10 Saarbruecken, 66117 Germany |
Date of Grant: 01/29/2024 Application Dated: 01/23/2024 |
| Philips Medical Systems North America Co. |
| 222 Jacobs Street |
| Cambridge, MA 02141 |
| Attention: Delroy Smith , Principal Architect |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC (Class II Permissive Change): Changing oscillator in accordance with Notification 202109-001. |
EAS Grant - Application N/TwZX20KxXK6R8wUZYUFA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 222 Jacobs Street Cambridge, MA 02141 United States |
Date of Grant: 01/29/2024 Application Dated: 01/23/2024 |
| Attention: Delroy Smith , Principal Architect |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00026 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC (Class II Permissive Change): Changing oscillator in accordance with Notification 202109-001. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 12/03/2020 Application Dated: 12/03/2020 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00014 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC to allow alternate transmit-receive switch. |
EAS Grant - Application 8NaUajfMT7ImZa9FThqhQw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 12/03/2020 Application Dated: 12/03/2020 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-OBRTBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Wireless Transducer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.00014 | 1550.0 Hz | 55K5F1D |
| Power output listed is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. C2PC to allow alternate transmit-receive switch. |
| Mail To: |