FCC ID PQC-OBTRNSBV1

Range Extender for OB and SRR measurements via WLAN

by Philips Medical Systems North America Co.

Grantee Code: PQC   Product Code: OBTRNSBV1
Latest application date: 2018-05-09

FCC ID Device Details

FCC IDPQC-OBTRNSBV1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePQC
Product CodeOBTRNSBV1
Applicant BusinessPhilips Medical Systems North America Co. 🇺🇸
Related Domains philips.com
Equipment ClassRange Extender for OB and SRR measurements via WLAN
Test FirmCTC advanced GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
608.375-613.625 MHzOriginal Equipment2018-05-09
5180-5240 MHzOriginal Equipment2018-05-09
2405-2480 MHzOriginal Equipment2018-05-09

Exhibits

DocumentTypeAvailableFile
User Manual, part1Users Manual2018-10-07PDF 4.4 MB
User Manual, part2Users Manual2018-10-07PDF 5.4 MB
Internal PhotosInternal Photos2018-10-07PDF 986.3 KB
External PhotosExternal Photos2018-10-07PDF 473.7 KB
Label & LocationID Label/Location Info2018-05-09PDF 208.4 KB
Test SetupTest Setup Photos2018-10-07PDF 724.5 KB
SAR Test SetupRF Exposure Info2018-05-09PDF 902.1 KB
Report MBAN conductedTest Report2018-05-09PDF 4.7 MB
Report OBRTest Report2018-05-09PDF 1.4 MB
Report SRR conductedTest Report2018-05-09PDF 2.6 MB
Report SRR radiatedTest Report2018-05-09PDF 1.8 MB
Report WLAN (DTS)Test Report2018-05-09PDF 4 MB
Report WLAN (DTS), Annex1Test Report2018-05-09PDF 5.9 MB
Report WLAN (DTS), Annex2Test Report2018-05-09PDF 3.6 MB
Report WLAN (NII) part1Test Report2018-05-09PDF 5 MB
Report WLAN (NII) part2Test Report2018-05-09PDF 2.5 MB
Report WLAN (NII), Annex1Test Report2018-05-09PDF 5.5 MB
Report WLAN (NII), Annex2Test Report2018-05-09PDF 5.4 MB
Report WLAN (NII), Annex3Test Report2018-05-09PDF 5.5 MB
Report WLAN (NII), Annex4Test Report2018-05-09PDF 5.5 MB
Report WLAN (NII), Annex5Test Report2018-05-09PDF 5.4 MB
Report WLAN (NII), Annex6Test Report2018-05-09PDF 5.4 MB
Report WLAN (NII), Annex7Test Report2018-05-09PDF 2.6 MB
Report WLAN (NII), DFSTest Report2018-05-09PDF 572.5 KB
Decl. re-used cond. ReportsCover Letter(s)2018-05-09PDF 128.1 KB
LTCCover Letter(s)2018-05-09PDF 671 KB
STCCover Letter(s)2018-05-09PDF 683.1 KB
SAR Cal-DataRF Exposure Info2018-05-09PDF 2.8 MB
SAR ReportRF Exposure Info2018-05-09PDF 1.5 MB
Block Diagram Metadata onlyBlock DiagramPDF 222.7 KB
Block Diagram, WLAN Metadata onlyBlock DiagramPDF 524 KB
Schematics WLAN Metadata onlySchematicsPDF 895 KB
Schematics part1 Metadata onlySchematicsPDF 350 KB
Schematics part2 Metadata onlyParts List/Tune Up InfoPDF 756.4 KB
Schematics part3 Metadata onlySchematicsPDF 188 KB
Op Des, BT not supported Metadata onlyOperational DescriptionPDF 724.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 591.3 KB
SW Security Description (NII) Metadata onlyOperational DescriptionPDF 66.7 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 403.1 KB
Tune-up Metadata onlyParts List/Tune Up InfoPDF 166.7 KB

Application Information

Application IDPkgiJywnyleljOdMr9aoKA==
Final Action Date2018-05-09
Application PurposeOriginal Equipment
Applicant FRN0017950635
ModelOBTRNSBV1
Frequency Range608.375-613.625 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionRange Extender for OB and SRR measurements via WLAN
Responsible PartyDelroy Smith, Principal Scientist / Project Leader, delroy.smith@philips.com , + 1 978 659 3382
Test FirmGerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com , 49-681-598-0
TCB EmailTCB@ctcadvanced.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date10/07/2018
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power listed is ERP for beloiw 1GHz and EIRP for above 1GHz.

Applications

Application IDDatePurpose
PkgiJywnyleljOdMr9aoKA==2018-05-09Original Equipment
N+ld9Eq+35jssHkJ8NxDQA==2018-05-09Original Equipment
2X5CpOuqCXJsgXlIJf06tQ==2018-05-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
608.375-613.625 MHz0.000212Hz111KF1D95H
2363-2387 MHz0.00135ppm2M64GXD95I
2393-2397 MHz0.0032435ppm2M61GXD95I
2405-2480 MHz0.00115CCC
2412-2462 MHz0.020415CCC
5180-5240 MHz0.012915ECC
5260-5320 MHz0.014515ECC
5500-5580 MHz0.018215ECC
5660-5700 MHz0.016215ECC
5745-5825 MHz0.012915ECC

Grants

TCB Grant - Application PkgiJywnyleljOdMr9aoKA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 05/09/2018

Application Dated: 04/10/2018
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Range Extender for OB and SRR measurements via WLAN
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95H 608.375  -  613.625 0.0002 12.0  Hz 111KF1D
95I 2363.0  -  2387.0 0.001 35.0  PM 2M64GXD
95I 2393.0  -  2397.0 0.00324 35.0  PM 2M61GXD

Output power listed is ERP for beloiw 1GHz and EIRP for above 1GHz.

EAS Grant - Application PkgiJywnyleljOdMr9aoKA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 05/09/2018

Application Dated: 04/10/2018
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Range Extender for OB and SRR measurements via WLAN
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95H 608.375  -  613.625 0.0002 12.0  Hz 111KF1D
95I 2363.0  -  2387.0 0.001 35.0  PM 2M64GXD
95I 2393.0  -  2397.0 0.00324 35.0  PM 2M61GXD

Output power listed is ERP for beloiw 1GHz and EIRP for above 1GHz.



TCB Grant - Application N+ld9Eq+35jssHkJ8NxDQA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 05/09/2018

Application Dated: 04/10/2018
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Range Extender for OB and SRR measurements via WLAN
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0129  
CC 15E 5260.0  -  5320.0 0.0145  
CC 15E 5500.0  -  5580.0 0.0182  
CC 15E 5660.0  -  5700.0 0.0162  
CC 15E 5745.0  -  5825.0 0.0129  

Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.659W/kg and 0.84W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application N+ld9Eq+35jssHkJ8NxDQA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 05/09/2018

Application Dated: 04/10/2018
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Range Extender for OB and SRR measurements via WLAN
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0129  
CC 15E 5260.0  -  5320.0 0.0145  
CC 15E 5500.0  -  5580.0 0.0182  
CC 15E 5660.0  -  5700.0 0.0162  
CC 15E 5745.0  -  5825.0 0.0129  

Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.659W/kg and 0.84W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 2X5CpOuqCXJsgXlIJf06tQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 05/09/2018

Application Dated: 04/10/2018
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: Range Extender for OB and SRR measurements via WLAN
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2480.0 0.001  
CC 15C 2412.0  -  2462.0 0.0204  

Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.659W/kg and 0.84W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2X5CpOuqCXJsgXlIJf06tQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 05/09/2018

Application Dated: 04/10/2018
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-OBTRNSBV1
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: Range Extender for OB and SRR measurements via WLAN
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2480.0 0.001  
CC 15C 2412.0  -  2462.0 0.0204  

Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.659W/kg and 0.84W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: