FCC ID PQC-WLANBV2

WLAN Module IEEE 802.11 a/b/g/n

by Philips Medical Systems North America Co.

Grantee Code: PQC   Product Code: WLANBV2
Latest application date: 2013-12-10

FCC ID Device Details

FCC IDPQC-WLANBV2
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePQC
Product CodeWLANBV2
Applicant BusinessPhilips Medical Systems North America Co. 🇺🇸
Related Domains philips.com
Equipment ClassWLAN Module IEEE 802.11 a/b/g/n
Test FirmCETECOM ICT Services GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2013-12-10
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2013-12-10
5180-5240 MHzOriginal Equipment2013-08-08
2412-2462 MHzOriginal Equipment2013-08-08

Exhibits

DocumentTypeAvailableFile
User Manual IntelliVue MP2Users Manual2013-12-10PDF 2.7 MB
User Manual IntelliVue CLUsers Manual2013-12-10PDF 2.2 MB
Installation InstructionsUsers Manual2013-08-08PDF 393.6 KB
Internal Photos IntelliVue CLInternal Photos2013-12-10PDF 1.1 MB
Internal Photos IntelliVue MP2Internal Photos2013-12-10PDF 397.2 KB
Internal PhotosInternal Photos2013-08-08PDF 2.3 MB
External Photos IntelliVue CLExternal Photos2013-12-10PDF 375 KB
External Photos IntelliVue MP2External Photos2013-12-10PDF 1.3 MB
Extenral PhotosExternal Photos2013-08-08PDF 383.8 KB
Label IntelliVue CLID Label/Location Info2013-12-10PDF 108.3 KB
Label IntelliVue MP2ID Label/Location Info2013-12-10PDF 217.4 KB
LabelID Label/Location Info2013-08-08PDF 36.6 KB
Test Setup PhotosTest Setup Photos2013-08-08PDF 1,007.3 KB
SAR Report IntelliVue CLRF Exposure Info2013-12-10PDF 1.4 MB
SAR Report IntelliVue MP2RF Exposure Info2013-12-10PDF 1.4 MB
DFS Client Test ReportTest Report2013-08-08PDF 572.5 KB
Test Report 2G4Test Report2013-08-08PDF 4.7 MB
Test Report 5G2 Part 1Test Report2013-08-08PDF 5 MB
Test Report 5G2 Part 2Test Report2013-08-08PDF 4.1 MB
Test Report 5G8Test Report2013-08-08PDF 4.1 MB
Declaration_UsedFrequenciesAttestation Statements2013-08-08PDF 617.7 KB
Delaration for the applicability of DFS reportAttestation Statements2013-08-08PDF 773.1 KB
Confidentiality request letterCover Letter(s)2013-12-10PDF 848.8 KB
Declaration on the using of certified moduleCover Letter(s)2013-12-10PDF 739.5 KB
Request for Permissive Change Class IICover Letter(s)2013-12-10PDF 688.3 KB
Modular Approval RequestCover Letter(s)2013-08-08PDF 1.6 MB
SAR Report Caldata IntelliVue CLRF Exposure Info2013-12-10PDF 1.3 MB
SAR Report Caldata IntelliVue MP2RF Exposure Info2013-12-10PDF 1.3 MB
RF Exposure InfoRF Exposure Info2013-08-08PDF 215.2 KB

Application Information

Application IDhXg5PVgL2rC0U/DBuPAxpw==
Final Action Date2013-12-10
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0004980637
Model-WLANBV2
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWLAN Module IEEE 802.11 a/b/g/n
Responsible PartyDelroy Smith, Principal Scientist / Project Leader, delroy.smith@philips.com , + 1 978 659 3382
Test FirmGerald Schmidt, CETECOM ICT Services GmbH, tcb@cetecom.com , 49-681-598-0
TCB Emailgerald.schmidt@cetecom.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPCII to allow collocated portable host devices. Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 1.22 W/kg.

Applications

Application IDDatePurpose
hXg5PVgL2rC0U/DBuPAxpw==2013-12-10Class II permissive change or modification of presently authorized equipment
LeBDArha6J0T8bn62dZxyA==2013-12-10Class II permissive change or modification of presently authorized equipment
WTlsc8pVe/UdfaK4d9bdaA==2013-08-08Original Equipment
2TKeth/chA0+ZZovbd9wcg==2013-08-08Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.046615CCC
2422-2462 MHz0.043115CCC
5180-5240 MHz0.0115ECC
5190-5230 MHz0.00415ECC
5260-5320 MHz0.016615ECC
5270-5310 MHz0.007815ECC
5500-5700 MHz0.020815ECC
5510-5670 MHz0.015915ECC
5745-5825 MHz0.063515CCC
5755-5835 MHz0.063815CCC

Grants

TCB Grant - Application WTlsc8pVe/UdfaK4d9bdaA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 08/08/2013

Application Dated: 08/08/2013
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01  
CC 15E 5190.0  -  5230.0 0.004  
CC 15E 5260.0  -  5320.0 0.0166  
CC 15E 5270.0  -  5310.0 0.0078  
CC 15E 5500.0  -  5700.0 0.0208  
CC 15E 5510.0  -  5670.0 0.0159  

Output Power listed is conducted.

Operation in 5.15-5.25 GHz band is for indoor use only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application WTlsc8pVe/UdfaK4d9bdaA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 08/08/2013

Application Dated: 08/08/2013
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01  
CC 15E 5190.0  -  5230.0 0.004  
CC 15E 5260.0  -  5320.0 0.0166  
CC 15E 5270.0  -  5310.0 0.0078  
CC 15E 5500.0  -  5700.0 0.0208  
CC 15E 5510.0  -  5670.0 0.0159  

Output Power listed is conducted.

Operation in 5.15-5.25 GHz band is for indoor use only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application LeBDArha6J0T8bn62dZxyA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 12/10/2013

Application Dated: 12/10/2013
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01  
CC 15E 5190.0  -  5230.0 0.004  
CC 15E 5260.0  -  5320.0 0.0166  
CC 15E 5270.0  -  5310.0 0.0078  
CC 15E 5500.0  -  5700.0 0.0208  
CC 15E 5510.0  -  5670.0 0.0159  

PCII to allow collocated portable host devices.

Output Power listed is conducted.

Operation in 5.15-5.25 GHz band is for indoor use only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

The highest reported SAR is 1.22 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application LeBDArha6J0T8bn62dZxyA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 12/10/2013

Application Dated: 12/10/2013
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01  
CC 15E 5190.0  -  5230.0 0.004  
CC 15E 5260.0  -  5320.0 0.0166  
CC 15E 5270.0  -  5310.0 0.0078  
CC 15E 5500.0  -  5700.0 0.0208  
CC 15E 5510.0  -  5670.0 0.0159  

PCII to allow collocated portable host devices.

Output Power listed is conducted.

Operation in 5.15-5.25 GHz band is for indoor use only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

The highest reported SAR is 1.22 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application hXg5PVgL2rC0U/DBuPAxpw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 12/10/2013

Application Dated: 12/10/2013
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0466  
CC 15C 2422.0  -  2462.0 0.0431  
CC 15C 5745.0  -  5825.0 0.0635  
CC 15C 5755.0  -  5835.0 0.0638  

PCII to allow collocated portable host devices.

Output Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

The highest reported SAR is 1.22 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application hXg5PVgL2rC0U/DBuPAxpw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 12/10/2013

Application Dated: 12/10/2013
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0466  
CC 15C 2422.0  -  2462.0 0.0431  
CC 15C 5745.0  -  5825.0 0.0635  
CC 15C 5755.0  -  5835.0 0.0638  

PCII to allow collocated portable host devices.

Output Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

The highest reported SAR is 1.22 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 2TKeth/chA0+ZZovbd9wcg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 08/08/2013

Application Dated: 08/08/2013
Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0466  
CC 15C 2422.0  -  2462.0 0.0431  
CC 15C 5745.0  -  5825.0 0.0635  
CC 15C 5755.0  -  5835.0 0.0638  

Output Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2TKeth/chA0+ZZovbd9wcg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 08/08/2013

Application Dated: 08/08/2013
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQC-WLANBV2
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Digital Transmission System
Notes: WLAN Module IEEE 802.11 a/b/g/n
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0466  
CC 15C 2422.0  -  2462.0 0.0431  
CC 15C 5745.0  -  5825.0 0.0635  
CC 15C 5755.0  -  5835.0 0.0638  

Output Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: