FCC ID PQCM2601A-95

Medical Telemetry Transmitter

by Philips Medical Systems North America Co.

Grantee Code: PQC   Product Code: M2601A95
Latest application date: 2002-09-19

FCC ID Device Details

FCC IDPQCM2601A-95
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePQC
Product CodeM2601A95
Applicant BusinessPhilips Medical Systems North America Co. 🇺🇸
Related Domains philips.com hsgmed.com
Equipment ClassMedical Telemetry Transmitter
Test FirmTest Site Services Co.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
608-614 MHzOriginal Equipment2002-09-19

Exhibits

DocumentTypeAvailableFile
User GuideUsers Manual2002-09-19PDF 3 MB
Internal photosInternal Photos2002-09-19PDF 632.5 KB
External 1 of 2External Photos2002-09-19PDF 34 KB
External 2 of 2External Photos2002-09-19PDF 221.2 KB
proposed back labelingExternal Photos2002-09-19PDF 62.1 KB
Label transmitter frontID Label/Location Info2002-09-19PDF 38.8 KB
Label transmitter rearID Label/Location Info2002-09-19PDF 62.1 KB
intended useOperational Description2002-09-19PDF 29 KB
TestReport1of2Test Report2002-09-19PDF 1.3 MB
TestReport2of2Test Report2002-09-19PDF 3 MB
CoverLetterCover Letter(s)2002-09-19PDF 28 KB
Submit CorrespondenceCover Letter(s)2002-09-19PDF 25.5 KB
Materials listsParts List/Tune Up Info2002-09-19PDF 46 KB
Scematics3of3 Metadata onlySchematicsPDF 132.4 KB
Schematics 1 of 5 Metadata onlySchematicsPDF 342.1 KB
Schematics 2 of 5 Metadata onlySchematicsPDF 201.6 KB
Schematics 3 of 5 Metadata onlySchematicsPDF 473.2 KB
Schematics 4 of 5 Metadata onlySchematicsPDF 236.8 KB
Schematics 5 of 5 Metadata onlySchematicsPDF 284.2 KB
Schematics1of3 Metadata onlySchematicsPDF 654.9 KB
Schematics2of3 Metadata onlySchematicsPDF 1.2 MB
OperationAndBlockDiag Metadata onlyOperational DescriptionPDF 26.9 KB

Application Information

Application IDYLTQKY5DOUT9MhlIg17YPw==
Final Action Date2002-09-19
Application PurposeOriginal Equipment
Applicant FRN0017950635
ModelM2601A-95
Frequency Range608-614 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionMedical Telemetry Transmitter
Responsible PartyDelroy Smith, Principal Scientist / Project Leader, delroy.smith@philips.com , + 1 978 659 3382
Technical ContactDenise Haley, Philips Medical Systems, denise_haley@hsgmed.com , 978-659-2701
Non-Technical ContactDenise Haley, Philips Medical Systems, denise_haley@hsgmed.com , 978-659-2701
Test FirmLawrence Lee, Test Site Services Co., llee@testsiteservices.com , 508-634-3444
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis application was originally granted on 08/20/2002.

Applications

Application IDDatePurpose
YLTQKY5DOUT9MhlIg17YPw==2002-09-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
608-614 MHz0.00400002.5000000000ppm16K0F1D95H

Grants

TCB Grant - Application YLTQKY5DOUT9MhlIg17YPw==

This application does not exist.

EAS Grant - Application YLTQKY5DOUT9MhlIg17YPw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Medical Systems North America Co.
3000 Minuteman Road
Andover, MA 01810-1099
United States
  Date of Grant: 09/19/2002

Application Dated: 05/09/2002
 
Attention: Delroy Smith , Principal Scientist / Project Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PQCM2601A-95
Name of Grantee:  Philips Medical Systems North America Co.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Medical Telemetry Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95H 608.0  -  614.0 0.004 2.5  PM 16K0F1D

Output is conducted.

This application was originally granted on 08/20/2002.



Mail To:
Denise Haley, Quality & Regulatory Engineer
Philips Medical Systems
3000 Minuteman Road
Andover, MA 01810