FCC ID PSMDATATAC001

Artema DataTAC POS Terminal

by Thales e-Transactions, Inc.

Grantee Code: PSM   Product Code: DATATAC001
Latest application date: 2001-11-09

FCC ID Device Details

FCC IDPSMDATATAC001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePSM
Product CodeDATATAC001
Applicant BusinessThales e-Transactions, Inc. 🇺🇸
Related Domains dassaultat.com aprel.com
Equipment ClassArtema DataTAC POS Terminal
Test FirmAPREL Laboratories

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-821 MHzOriginal Equipment2001-11-09

Exhibits

DocumentTypeAvailableFile
ex9 manualUsers Manual2001-11-09PDF 336.7 KB
ex5 internal external pixInternal Photos2001-11-09PDF 2.1 MB
ex4 label infoID Label/Location Info2001-11-09PDF 569.9 KB
ex3 operational technical descriptionOperational Description2001-11-09PDF 23.5 KB
ex2a erp rptTest Report2001-11-09PDF 892.6 KB
ex2b spuriousTest Report2001-11-09PDF 2.8 MB
ex2c bandwidthTest Report2001-11-09PDF 121.2 KB
ex2e frequency stabilityTest Report2001-11-09PDF 61.1 KB
ex10 attestation statementsAttestation Statements2001-11-09PDF 260 KB
contentsCover Letter(s)2001-11-09PDF 12.4 KB
ex1 authorizations confidentialityCover Letter(s)2001-11-09PDF 729.2 KB
ex11 sar rptRF Exposure Info2001-11-09PDF 1.5 MB
ex6 block diagram Metadata onlyBlock DiagramPDF 12.2 KB
ex7 schematics Metadata onlySchematicsPDF 785.7 KB
ex8 parts list Metadata onlyParts List/Tune Up InfoPDF 1.2 MB

Application Information

Application IDUSDJqoa/me1PAuUdEWOsbg==
Final Action Date2001-11-09
Application PurposeOriginal Equipment
Applicant FRN0005796503
ModelDATATAC001
Frequency Range806-821 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionArtema DataTAC POS Terminal
Responsible PartyRandy Burnette, VP of Engineering, randy.burnette@dassaultat.com , 770-558-5556
AgentJayanta (Jay) Jayanta (Jay) Jayanta (Jay), APREL Laboratories, j.sarkar@aprel.com , (613)820-2730
Technical ContactJayanta (Jay) K Sarkar, APREL Laboratories, j.sarkar@aprel.com , (613)820-2730
Non-Technical ContactJayanta (Jay) K Sarkar, APREL Laboratories, j.sarkar@aprel.com , (613)820-2730
Test FirmJay Sarkar, APREL Laboratories, j.sarkar@aprel.com , 613-820-2730
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP. This transmitter operates with a specific hand-held terminal and has been tested for SAR compliance at 4.0 cm from the antenna for mobile and hand-held configurations. Users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value is - Body: 0.14 W/kg at 25% duty factor.

Applications

Application IDDatePurpose
USDJqoa/me1PAuUdEWOsbg==2001-11-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-821 MHz1.19100002.5000000000ppm20K0F1D90

Grants

TCB Grant - Application USDJqoa/me1PAuUdEWOsbg==

This application does not exist.

EAS Grant - Application USDJqoa/me1PAuUdEWOsbg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Thales e-Transactions, Inc.
53 Perimeter Center East Suite 176
Atlanta, GA 30346
United States
  Date of Grant: 11/09/2001

Application Dated: 09/13/2001
 
Attention: Randy Burnette , VP of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PSMDATATAC001
Name of Grantee:  Thales e-Transactions, Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Artema DataTAC POS Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  821.0 1.191 2.5  PM 20K0F1D

Output is ERP. This transmitter operates with a specific hand-held terminal and has been tested for SAR compliance at 4.0 cm from the antenna for mobile and hand-held configurations. Users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value is - Body: 0.14 W/kg at 25% duty factor.



Mail To: