FCC ID PU5900-001
Flo Home Water Monitoring and Control
by Wistron Corporation
Grantee Code: PU5 Product Code: 900001
Latest application date: 2018-01-25
FCC ID Device Details
| FCC ID | PU5900-001 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PU5 |
| Product Code | 900001 |
| Applicant Business | Wistron Corporation 🇹🇼 |
| Related Domains | |
| Equipment Class | Flo Home Water Monitoring and Control |
| Test Firm | International Standards Laboratory Corp. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2018-01-25 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual_revised0124 | Users Manual | 2018-07-25 | PDF 1.3 MB |
| Internal Photos | Internal Photos | 2018-07-25 | PDF 888.2 KB |
| External Photos | External Photos | 2018-07-25 | PDF 483.1 KB |
| ID Label/Location Info | ID Label/Location Info | 2018-01-25 | PDF 314.6 KB |
| Test Setup Photos | Test Setup Photos | 2018-07-25 | PDF 532.5 KB |
| Test Report | Test Report | 2018-01-25 | PDF 2.5 MB |
| Confidentiality Metadata only | Cover Letter(s) | 2018-01-25 | PDF 235 KB |
| Confidentiality_revised0124 | Cover Letter(s) | 2018-01-25 | PDF 601.7 KB |
| Declaration Letter | Cover Letter(s) | 2018-01-25 | PDF 860.5 KB |
| Declaration of authorization | Cover Letter(s) | 2018-01-25 | PDF 142 KB |
| MPE | RF Exposure Info | 2018-01-25 | PDF 18 KB |
| Block Diagram Metadata only | Block Diagram | PDF 342.6 KB | |
| Schematics Metadata only | Schematics | PDF 660.5 KB | |
| Operational Description Metadata only | Operational Description | PDF 12 KB |
Application Information
| Application ID | GvhsxOROV8j3wy1/91lc+w== |
|---|---|
| Final Action Date | 2018-01-25 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006267215 |
| Model | 900-001 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Flo Home Water Monitoring and Control |
| Responsible Party | Roy Hsieh, RF Regulatory Manager, roy_hsieh@wistron.com |
| Technical Contact | Dino Chen, International Standards Laboratory, dino_chen@isl.com.tw |
| Non-Technical Contact | Dino Chen, International Standards Laboratory, dino_chen@isl.com.tw |
| Test Firm | Angus Chu, International Standards Laboratory Corp., angus_chu@isl.com.tw |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/25/2018 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| GvhsxOROV8j3wy1/91lc+w== | 2018-01-25 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.2100000 | 15C |
Grants
TCB Grant - Application GvhsxOROV8j3wy1/91lc+w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 01/25/2018 Application Dated: 01/24/2018 |
| Wistron Corporation |
| 21F., No. 88, Sec. 1, HsinTai 5th Rd., |
| Hsichih Dist, |
| New Taipei City 221, 221 Taiwan |
| Attention: Roy Hsieh , RF Regulatory Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PU5900-001 |
| Name of Grantee: | Wistron Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Flo Home Water Monitoring and Control |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.21 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
EAS Grant - Application GvhsxOROV8j3wy1/91lc+w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Wistron Corporation 21F., No. 88, Sec. 1, HsinTai 5th Rd., Hsichih Dist, New Taipei City 221, 221 Taiwan |
Date of Grant: 01/25/2018 Application Dated: 01/24/2018 |
| Attention: Roy Hsieh , RF Regulatory Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PU5900-001 |
| Name of Grantee: | Wistron Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Flo Home Water Monitoring and Control |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.21 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |