FCC ID PWX-C61
GSM 850/1900 Mobile Phone
by BenQ Mobile GmbH & Co. OHG
Grantee Code: PWX Product Code: C61
Latest application date: 2003-12-12
FCC ID Device Details
| FCC ID | PWX-C61 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PWX |
| Product Code | C61 |
| Applicant Business | BenQ Mobile GmbH & Co. OHG 🇩🇪 |
| Related Domains | |
| Equipment Class | GSM 850/1900 Mobile Phone |
| Test Firm | Cetecom Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2003-12-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2003-12-12 | PDF 1.9 MB |
| Internal Photos | Internal Photos | 2003-12-12 | PDF 1.7 MB |
| External Photos | External Photos | 2003-12-12 | PDF 295.5 KB |
| Label Info | ID Label/Location Info | 2003-12-12 | PDF 246.1 KB |
| Test Setup Photos | Test Setup Photos | 2003-12-12 | PDF 174.1 KB |
| Test Report | Test Report | 2003-12-12 | PDF 293.8 KB |
| Test Report Conducted | Test Report | 2003-12-12 | PDF 293.8 KB |
| Confidentiality Request | Cover Letter(s) | 2003-12-12 | PDF 32.7 KB |
| SAR Calibration Data | RF Exposure Info | 2003-12-12 | PDF 2 MB |
| SAR Plots | RF Exposure Info | 2003-12-12 | PDF 1.7 MB |
| SAR Report | RF Exposure Info | 2003-12-12 | PDF 1.1 MB |
Application Information
| Application ID | FT9TBnGlyXVVzSwU8NeBIw== |
|---|---|
| Final Action Date | 2003-12-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0014952428 |
| Model | C61 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | GSM 850/1900 Mobile Phone |
| Responsible Party | Dr. Martin Weinberger, Engineering Manager, martin.weinberger@benq.com |
| Technical Contact | Lothar Schmidt, CETECOM Inc., Lothar.Schmidt@cetecomusa.com |
| Non-Technical Contact | Lothar Schmidt, CETECOM Inc., Lothar.Schmidt@cetecomusa.com |
| Test Firm | Lothar Schmidt, Cetecom Inc., lothar.schmidt@cetecomusa.com |
| TCB Email | gerald.schmidt@ict.cetecom.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Push-to talk (PTT) operating configuration is based on a separation distance of 25 mm between the front of the unit and the body to the user. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.621 W/kg, Body: 0.370 W/kg; Part 22 - Head: 0.656 W/kg, Body: 0.621 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| FT9TBnGlyXVVzSwU8NeBIw== | 2003-12-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application FT9TBnGlyXVVzSwU8NeBIw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 12/12/2003 Application Dated: 12/12/2003 |
| BenQ Mobile GmbH & Co. OHG |
| Haidenauplatz 1 |
| Munich, 81667 Germany |
| Attention: Dr. Martin Weinberger , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PWX-C61 |
| Name of Grantee: | BenQ Mobile GmbH & Co. OHG |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM 850/1900 Mobile Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.95 | 0.0234 PM | 300KGXW | |
| 22H | 824.2 - 848.8 | 0.948 | 0.0275 PM | 300KGXW |
| Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Push-to talk (PTT) operating configuration is based on a separation distance of 25 mm between the front of the unit and the body to the user. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.621 W/kg, Body: 0.370 W/kg; Part 22 - Head: 0.656 W/kg, Body: 0.621 W/kg. |
EAS Grant - Application FT9TBnGlyXVVzSwU8NeBIw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BenQ Mobile GmbH & Co. OHG Haidenauplatz 1 Munich, 81667 Germany |
Date of Grant: 12/12/2003 Application Dated: 12/12/2003 |
| Attention: Dr. Martin Weinberger , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PWX-C61 |
| Name of Grantee: | BenQ Mobile GmbH & Co. OHG |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM 850/1900 Mobile Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.95 | 0.0234 PM | 300KGXW | |
| 22H | 824.2 - 848.8 | 0.948 | 0.0275 PM | 300KGXW |
| Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Push-to talk (PTT) operating configuration is based on a separation distance of 25 mm between the front of the unit and the body to the user. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.621 W/kg, Body: 0.370 W/kg; Part 22 - Head: 0.656 W/kg, Body: 0.621 W/kg. |
| Mail To: |