FCC ID PWX-M65

GSM/PCS 900/1800/1900 MHz Mobile Phone

by BenQ Mobile GmbH & Co. OHG

Grantee Code: PWX   Product Code: M65
Latest application date: 2004-04-21

FCC ID Device Details

FCC IDPWX-M65
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePWX
Product CodeM65
Applicant BusinessBenQ Mobile GmbH & Co. OHG 🇩🇪
Related Domains benq.com
Equipment ClassGSM/PCS 900/1800/1900 MHz Mobile Phone
Test FirmCetecom Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2004-04-21

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2004-04-21PDF 2.2 MB
Internal PhotosInternal Photos2004-04-21PDF 1.1 MB
External PhotosExternal Photos2004-04-21PDF 443.5 KB
ID Label and Location InfoID Label/Location Info2004-04-21PDF 274 KB
Test Setup PhotosTest Setup Photos2004-04-21PDF 208.1 KB
Test ReportTest Report2004-04-21PDF 531.2 KB
Test Report Conducted PowerTest Report2004-04-21PDF 409.8 KB
Confidentiality RequestCover Letter(s)2004-04-21PDF 32.8 KB
SAR Calibration DataRF Exposure Info2004-04-21PDF 1.2 MB
SAR PlotsRF Exposure Info2004-04-21PDF 776.7 KB
SAR ReportRF Exposure Info2004-04-21PDF 831.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 105.7 KB
Schematics Metadata onlySchematicsPDF 818.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 114.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 867.7 KB
Tune Uo Info Metadata onlyParts List/Tune Up InfoPDF 72.7 KB

Application Information

Application IDsNOZbBLptfsBxN1EmV7N0w==
Final Action Date2004-04-21
Application PurposeOriginal Equipment
Applicant FRN0014952428
ModelM65
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionGSM/PCS 900/1800/1900 MHz Mobile Phone
Responsible PartyDr. Martin Weinberger, Engineering Manager, martin.weinberger@benq.com , +49 89 722 37148
Test FirmLothar Schmidt, Cetecom Inc., lothar.schmidt@cetecomusa.com , 408-586-6200
TCB Emailgerald.schmidt@ict.cetecom.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is EIRP. This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to Siemens accessory designated for this product or belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 22 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Head: 0.745 W/kg, Body: 0.535 W/kg. This mobile contains 900 MHz and 1800 MHz function that is not operational in U.S. Territories.

Applications

Application IDDatePurpose
sNOZbBLptfsBxN1EmV7N0w==2004-04-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz0.94600000.0210000000ppm300KGXW24E

Grants

TCB Grant - Application sNOZbBLptfsBxN1EmV7N0w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 04/21/2004

Application Dated: 04/21/2004
BenQ Mobile GmbH & Co. OHG
Haidenauplatz 1
Munich, 81667
Germany
 
Attention: Dr. Martin Weinberger , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PWX-M65
Name of Grantee:  BenQ Mobile GmbH & Co. OHG
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM/PCS 900/1800/1900 MHz Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.946 0.021  PM 300KGXW

Power listed is EIRP. This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to Siemens accessory designated for this product or belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 22 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Head: 0.745 W/kg, Body: 0.535 W/kg. This mobile contains 900 MHz and 1800 MHz function that is not operational in U.S. Territories.

EAS Grant - Application sNOZbBLptfsBxN1EmV7N0w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

BenQ Mobile GmbH & Co. OHG
Haidenauplatz 1
Munich, 81667
Germany
  Date of Grant: 04/21/2004

Application Dated: 04/21/2004
 
Attention: Dr. Martin Weinberger , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PWX-M65
Name of Grantee:  BenQ Mobile GmbH & Co. OHG
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM/PCS 900/1800/1900 MHz Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.946 0.021  PM 300KGXW

Power listed is EIRP. This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to Siemens accessory designated for this product or belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 22 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Head: 0.745 W/kg, Body: 0.535 W/kg. This mobile contains 900 MHz and 1800 MHz function that is not operational in U.S. Territories.



Mail To: