FCC ID PX8CFNG-ARU
Comflex NG
by Comba Telecom Network Systems Limited
Grantee Code: PX8 Product Code: CFNGARU
Latest application date: 2023-05-16
FCC ID Device Details
| FCC ID | PX8CFNG-ARU |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PX8 |
| Product Code | CFNGARU |
| Applicant Business | Comba Telecom Network Systems Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Comflex NG |
| Test Firm | SGS-CSTC Standards Technical Services Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 728-746 MHz | Original Equipment | 2023-05-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-05-16 | PDF 1.2 MB |
| Internal Photos | Internal Photos | 2023-05-16 | PDF 1.4 MB |
| External Photos | External Photos | 2023-05-16 | PDF 3.1 MB |
| Label and location | ID Label/Location Info | 2023-05-16 | PDF 150.3 KB |
| Test Setup Photos | Test Setup Photos | 2023-05-16 | PDF 1.3 MB |
| Test Data and Result | Test Report | 2023-05-16 | PDF 3.7 MB |
| Test report | Test Report | 2023-05-16 | PDF 859.2 KB |
| Attestation letter | Attestation Statements | 2023-05-16 | PDF 128.2 KB |
| QSF27-14-04_Rev1.0_Applicant_Declaration_Letter | Attestation Statements | 2023-05-16 | PDF 123 KB |
| SGS_FCC_U.S. agent Letter | Attestation Statements | 2023-05-16 | PDF 285 KB |
| Authority letter | Cover Letter(s) | 2023-05-16 | PDF 54.9 KB |
| Confidential letter | Cover Letter(s) | 2023-05-16 | PDF 112 KB |
| MPE report | RF Exposure Info | 2023-05-16 | PDF 607.4 KB |
| Block diagram Metadata only | Block Diagram | PDF 677.5 KB | |
| Schematic Metadata only | Schematics | PDF 957.2 KB | |
| Operation description Metadata only | Operational Description | PDF 256.1 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 441.4 KB |
Application Information
| Application ID | KxRq20+VargUyLVfCpXWRw== |
|---|---|
| Final Action Date | 2023-05-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006794697 |
| Model | CFNG-ARU |
| Frequency Range | 728-746 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Comflex NG |
| Responsible Party | Ronin Gong, Director, gongwei@comba-network.com |
| Agent | Bonnie Bonnie Bonnie, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.liao@sgs.com |
| Technical Contact | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.liao@sgs.com |
| Non-Technical Contact | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.liao@sgs.com |
| Test Firm | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd., bonnie.liao@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 20cm separation distance from all persons as described in this filling. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| KxRq20+VargUyLVfCpXWRw== | 2023-05-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 728-746 MHz | 0.092 | Amp | W7D | 27 |
| 746-756 MHz | 0.077 | Amp | G7D | 27 |
| 746-756 MHz | 0.077 | Amp | W7D | 27 |
| 869-894 MHz | 0.123 | Amp | G7D | 22 |
| 869-894 MHz | 0.123 | Amp | W7D | 22 |
| 1930-1995 MHz | 0.111 | Amp | W7D | 24E |
| 1930-1995 MHz | 0.111 | Amp | G7D | 24E |
| 2110-2180 MHz | 0.12 | Amp | G7D | 27 |
| 2110-2180 MHz | 0.12 | Amp | W7D | 27 |
| 2496-2690 MHz | 0.216 | Amp | G7D | 27 |
| 2496-2690 MHz | 0.216 | Amp | W7D | 27 |
| 3700-3980 MHz | 0.233 | Amp | G7D | 27 |
| 3700-3980 MHz | 0.233 | Amp | W7D | 27 |
Grants
TCB Grant - Application KxRq20+VargUyLVfCpXWRw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 05/16/2023 Application Dated: 05/16/2023 |
| Comba Telecom Network Systems Limited |
| Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science |
| Park West Avenue, HK Science Park, Pak Shek Kok |
| HongKong, 510663 China |
| Attention: Ronin Gong , Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PX8CFNG-ARU |
| Name of Grantee: | Comba Telecom Network Systems Limited |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Comflex NG |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 728.0 - 746.0 | 0.092 | Amp | G7D | |
| 27 | 728.0 - 746.0 | 0.092 | Amp | W7D | |
| 27 | 746.0 - 756.0 | 0.077 | Amp | G7D | |
| 27 | 746.0 - 756.0 | 0.077 | Amp | W7D | |
| 22 | 869.0 - 894.0 | 0.123 | Amp | G7D | |
| 22 | 869.0 - 894.0 | 0.123 | Amp | W7D | |
| 27 | 2110.0 - 2180.0 | 0.12 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 0.12 | Amp | W7D | |
| 24E | 1930.0 - 1995.0 | 0.111 | Amp | G7D | |
| 24E | 1930.0 - 1995.0 | 0.111 | Amp | W7D | |
| 27 | 2496.0 - 2690.0 | 0.216 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.216 | Amp | W7D | |
| 27 | 3700.0 - 3980.0 | 0.233 | Amp | G7D | |
| 27 | 3700.0 - 3980.0 | 0.233 | Amp | W7D |
| In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 20cm separation distance from all persons as described in this filling. |
EAS Grant - Application KxRq20+VargUyLVfCpXWRw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Comba Telecom Network Systems Limited Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok HongKong, 510663 China |
Date of Grant: 05/16/2023 Application Dated: 05/16/2023 |
| Attention: Ronin Gong , Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PX8CFNG-ARU |
| Name of Grantee: | Comba Telecom Network Systems Limited |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Comflex NG |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 728.0 - 746.0 | 0.092 | Amp | G7D | |
| 27 | 728.0 - 746.0 | 0.092 | Amp | W7D | |
| 27 | 746.0 - 756.0 | 0.077 | Amp | G7D | |
| 27 | 746.0 - 756.0 | 0.077 | Amp | W7D | |
| 22 | 869.0 - 894.0 | 0.123 | Amp | G7D | |
| 22 | 869.0 - 894.0 | 0.123 | Amp | W7D | |
| 27 | 2110.0 - 2180.0 | 0.12 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 0.12 | Amp | W7D | |
| 24E | 1930.0 - 1995.0 | 0.111 | Amp | G7D | |
| 24E | 1930.0 - 1995.0 | 0.111 | Amp | W7D | |
| 27 | 2496.0 - 2690.0 | 0.216 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.216 | Amp | W7D | |
| 27 | 3700.0 - 3980.0 | 0.233 | Amp | G7D | |
| 27 | 3700.0 - 3980.0 | 0.233 | Amp | W7D |
| In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a remote unit as part of a system along with master unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in downlink path; operations if any with master unit connected to antenna or amplifier in the downlink require separate equipment authorization. Antenna installed for each remote unit must provide a minimum 20cm separation distance from all persons as described in this filling. |
| Mail To: |