FCC ID PX8CFNG-MU
Comflex NG
by Comba Telecom Network Systems Limited
Grantee Code: PX8 Product Code: CFNGMU
Latest application date: 2023-05-19
FCC ID Device Details
| FCC ID | PX8CFNG-MU |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PX8 |
| Product Code | CFNGMU |
| Applicant Business | Comba Telecom Network Systems Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Comflex NG |
| Test Firm | SGS-CSTC Standards Technical Services Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 698-716 MHz | Original Equipment | 2023-05-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2023-05-19 | PDF 1.2 MB |
| Internal Photos | Internal Photos | 2023-05-19 | PDF 2.8 MB |
| External Photos | External Photos | 2023-05-19 | PDF 3 MB |
| Label and location | ID Label/Location Info | 2023-05-19 | PDF 140.3 KB |
| Test Setup Photos | Test Setup Photos | 2023-05-19 | PDF 1.3 MB |
| Test Data and Result | Test Report | 2023-05-19 | PDF 3.8 MB |
| Test report | Test Report | 2023-05-19 | PDF 855.2 KB |
| Applicant Declaration Letter | Attestation Statements | 2023-05-19 | PDF 123 KB |
| Attestation letter | Attestation Statements | 2023-05-19 | PDF 138.8 KB |
| U.S. agent Letter | Attestation Statements | 2023-05-19 | PDF 285.2 KB |
| Authority letter | Cover Letter(s) | 2023-05-19 | PDF 55 KB |
| Confidential letter | Cover Letter(s) | 2023-05-19 | PDF 111.6 KB |
| MPE report | RF Exposure Info | 2023-05-19 | PDF 621.8 KB |
| Block Diagram Metadata only | Block Diagram | PDF 677.5 KB | |
| Schematic Metadata only | Schematics | PDF 5.8 MB | |
| Operation description Metadata only | Operational Description | PDF 232 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 441.5 KB |
Application Information
| Application ID | jSDRDd5O2nQrZCEdUmdGBA== |
|---|---|
| Final Action Date | 2023-05-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006794697 |
| Model | CFNG-MU |
| Frequency Range | 698-716 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Comflex NG |
| Responsible Party | Ronin Gong, Director, gongwei@comba-network.com |
| Agent | Bonnie Bonnie Bonnie, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.Liao@sgs.com |
| Technical Contact | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.Liao@sgs.com |
| Non-Technical Contact | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd, Bonnie.Liao@sgs.com |
| Test Firm | Bonnie Liao, SGS-CSTC Standards Technical Services Co., Ltd., bonnie.liao@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a master unit as part of a system along with remote unit components as described in this filing, and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in uplink path; operations if any with master unit connected to antenna or amplifier in the uplink require separate equipment authorization. Antenna installed for master unit must provide a minimum 24cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 14.0dBi. The installation height of the antenna for AWS 1710-1755 MHz band operations is limited to 10 meters above ground, for compliance with Section 27.50. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| jSDRDd5O2nQrZCEdUmdGBA== | 2023-05-19 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 698-716 MHz | 0.104 | Amp | W7D | 27 |
| 777-787 MHz | 0.097 | Amp | G7D | 27 |
| 777-787 MHz | 0.097 | Amp | W7D | 27 |
| 824-849 MHz | 0.122 | Amp | G7D | 22 |
| 824-849 MHz | 0.122 | Amp | W7D | 22 |
| 1710-1755 MHz | 0.122 | Amp | G7D | 27 |
| 1710-1755 MHz | 0.122 | Amp | W7D | 27 |
| 1850-1915 MHz | 0.123 | Amp | W7D | 24E |
| 1850-1915 MHz | 0.123 | Amp | G7D | 24E |
| 2496-2690 MHz | 0.234 | Amp | G7D | 27 |
| 2496-2690 MHz | 0.234 | Amp | W7D | 27 |
Grants
TCB Grant - Application jSDRDd5O2nQrZCEdUmdGBA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 05/19/2023 Application Dated: 05/19/2023 |
| Comba Telecom Network Systems Limited |
| Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science |
| Park West Avenue, HK Science Park, Pak Shek Kok |
| HongKong, 510663 China |
| Attention: Ronin Gong , Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PX8CFNG-MU |
| Name of Grantee: | Comba Telecom Network Systems Limited |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Comflex NG |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 698.0 - 716.0 | 0.104 | Amp | G7D | |
| 27 | 698.0 - 716.0 | 0.104 | Amp | W7D | |
| 27 | 777.0 - 787.0 | 0.097 | Amp | G7D | |
| 27 | 777.0 - 787.0 | 0.097 | Amp | W7D | |
| 22 | 824.0 - 849.0 | 0.122 | Amp | G7D | |
| 22 | 824.0 - 849.0 | 0.122 | Amp | W7D | |
| 27 | 1710.0 - 1755.0 | 0.122 | Amp | G7D | |
| 27 | 1710.0 - 1755.0 | 0.122 | Amp | W7D | |
| 24E | 1850.0 - 1915.0 | 0.123 | Amp | G7D | |
| 24E | 1850.0 - 1915.0 | 0.123 | Amp | W7D | |
| 27 | 2496.0 - 2690.0 | 0.234 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.234 | Amp | W7D |
| In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a master unit as part of a system along with remote unit components as described in this filing, and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in uplink path; operations if any with master unit connected to antenna or amplifier in the uplink require separate equipment authorization. Antenna installed for master unit must provide a minimum 24cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 14.0dBi. The installation height of the antenna for AWS 1710-1755 MHz band operations is limited to 10 meters above ground, for compliance with Section 27.50. |
EAS Grant - Application jSDRDd5O2nQrZCEdUmdGBA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Comba Telecom Network Systems Limited Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok HongKong, 510663 China |
Date of Grant: 05/19/2023 Application Dated: 05/19/2023 |
| Attention: Ronin Gong , Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PX8CFNG-MU |
| Name of Grantee: | Comba Telecom Network Systems Limited |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Comflex NG |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 698.0 - 716.0 | 0.104 | Amp | G7D | |
| 27 | 698.0 - 716.0 | 0.104 | Amp | W7D | |
| 27 | 777.0 - 787.0 | 0.097 | Amp | G7D | |
| 27 | 777.0 - 787.0 | 0.097 | Amp | W7D | |
| 22 | 824.0 - 849.0 | 0.122 | Amp | G7D | |
| 22 | 824.0 - 849.0 | 0.122 | Amp | W7D | |
| 27 | 1710.0 - 1755.0 | 0.122 | Amp | G7D | |
| 27 | 1710.0 - 1755.0 | 0.122 | Amp | W7D | |
| 24E | 1850.0 - 1915.0 | 0.123 | Amp | G7D | |
| 24E | 1850.0 - 1915.0 | 0.123 | Amp | W7D | |
| 27 | 2496.0 - 2690.0 | 0.234 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.234 | Amp | W7D |
| In-Building DAS Industrial Booster. Power output listed is conducted. This transmitter operates as a master unit as part of a system along with remote unit components as described in this filing, and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in uplink path; operations if any with master unit connected to antenna or amplifier in the uplink require separate equipment authorization. Antenna installed for master unit must provide a minimum 24cm separation distance from all persons as described in this filling. The antenna(s) used for the transmitter must be fixed-mounted on output permanent structures with maximum permissive gain of external antenna up to 14.0dBi. The installation height of the antenna for AWS 1710-1755 MHz band operations is limited to 10 meters above ground, for compliance with Section 27.50. |
| Mail To: |