FCC ID PXITR-CA1102

Dual Band Tri-Mode CDMA Cellular Transceiver

by Sony Ericsson Mobile Communications Inc.

Grantee Code: PXI   Product Code: TRCA1102
Latest application date: 2003-01-29

FCC ID Device Details

FCC IDPXITR-CA1102
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePXI
Product CodeTRCA1102
Applicant BusinessSony Ericsson Mobile Communications Inc. 🇺🇸
Related Domains sonyericsson.com
Equipment ClassDual Band Tri-Mode CDMA Cellular Transceiver

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.04-848.97 MHzOriginal Equipment2003-01-29

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2003-01-29PDF 1.6 MB
Internal PhotosInternal Photos2003-01-29PDF 273.8 KB
External PhotosExternal Photos2003-01-29PDF 173.9 KB
Label and LocationID Label/Location Info2003-01-29PDF 176.4 KB
Revised Test ReportTest Report2003-01-29PDF 1.2 MB
AttestationsAttestation Statements2003-01-29PDF 119.3 KB
Cover and Confid RequestCover Letter(s)2003-01-29PDF 20.7 KB
SAR InsertRF Exposure Info2003-01-29PDF 47.2 KB
SAR Report Part 1RF Exposure Info2003-01-29PDF 3.8 MB
SAR Report Part 2RF Exposure Info2003-01-29PDF 3.8 MB
Block Metadata onlyBlock DiagramPDF 174.7 KB
Schema Metadata onlySchematicsPDF 2.5 MB
Technical Description Metadata onlyOperational DescriptionPDF 91.7 KB
Parts and Calibration Procedure Metadata onlyParts List/Tune Up InfoPDF 84.7 KB

Application Information

Application ID8r729VJwV33X1ft6cV1xEg==
Final Action Date2003-01-29
Application PurposeOriginal Equipment
Applicant FRN0005029400
ModelTR-CA1102
Frequency Range824.04-848.97 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionDual Band Tri-Mode CDMA Cellular Transceiver
Responsible PartyJasen Kolev, GSM Type Approval, Jasen.P.Kolev@sonyericsson.com , 919-472-6631
TCB Emailhotline@americanTCB.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating conditions is limited to the specific acessories tested for this filing, or similar accessories that have no metallic component in the assembly and must provide at least 20mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: AMPS Band Head:1.42W/kg; Body-worn 1.33W/kg, PCS Band Head:1.49W/kg; Body-worn 1.04W/kg

Applications

Application IDDatePurpose
8r729VJwV33X1ft6cV1xEg==2003-01-29Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.04-848.97 MHz0.3012.5ppm40K0F8W22BC
824.04-848.97 MHz0.3012.5ppm40K0F1D22BC
824.73-848.19 MHz0.22.5ppm1M25F9W22.901(d)BC
1851.25-1908.75 MHz0.1772.5ppm1M25F9W24EBC

Grants

TCB Grant - Application 8r729VJwV33X1ft6cV1xEg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 01/29/2003

Application Dated: 01/29/2003
Sony Ericsson Mobile Communications Inc.
7001 Development Drive
P.O. Box 13969,
Research Triangle Park, NC 27709
 
Attention: Jasen Kolev , GSM Type Approval

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PXITR-CA1102
Name of Grantee:  Sony Ericsson Mobile Communications Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Dual Band Tri-Mode CDMA Cellular Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22 824.04  -  848.97 0.301 2.5  PM 40K0F8W
BC 22 824.04  -  848.97 0.301 2.5  PM 40K0F1D
BC 22.901(d) 824.73  -  848.19 0.2 2.5  PM 1M25F9W
BC 24E 1851.25  -  1908.75 0.177 2.5  PM 1M25F9W

Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating conditions is limited to the specific acessories tested for this filing, or similar accessories that have no metallic component in the assembly and must provide at least 20mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: AMPS Band Head:1.42W/kg; Body-worn 1.33W/kg, PCS Band Head:1.49W/kg; Body-worn 1.04W/kg

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application 8r729VJwV33X1ft6cV1xEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sony Ericsson Mobile Communications Inc.
7001 Development Drive P.O. Box 13969,
Research Triangle Park, NC 27709
United States
  Date of Grant: 01/29/2003

Application Dated: 01/29/2003
 
Attention: Jasen Kolev , GSM Type Approval

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PXITR-CA1102
Name of Grantee:  Sony Ericsson Mobile Communications Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Dual Band Tri-Mode CDMA Cellular Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22 824.04  -  848.97 0.301 2.5  PM 40K0F8W
BC 22 824.04  -  848.97 0.301 2.5  PM 40K0F1D
BC 22.901(d) 824.73  -  848.19 0.2 2.5  PM 1M25F9W
BC 24E 1851.25  -  1908.75 0.177 2.5  PM 1M25F9W

Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating conditions is limited to the specific acessories tested for this filing, or similar accessories that have no metallic component in the assembly and must provide at least 20mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: AMPS Band Head:1.42W/kg; Body-worn 1.33W/kg, PCS Band Head:1.49W/kg; Body-worn 1.04W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: