RDRMP001 Frequency Hopping Spread Spectrum... - FCC ID PYFRDRMP001

FCC ID PYFRDRMP001

Frequency hopping algorithm

Frequency Hopping Spread Spectrum Transmitter

by Symbol Technologies, Inc

Document preview loads when visible.

Document Details

FCC IDPYFRDRMP001
Document ID226973
Document TypeTest Report
DescriptionFrequency hopping algorithm
Document TitleFrequency Hopping Algorithm
ApplicantSymbol Technologies, Inc
Equipment ClassFrequency Hopping Spread Spectrum Transmitter
Product CodeRDRMP001
Application IDWYqU9RdI1puzjWLyETQaFw==
Application PurposeOriginal Equipment
Application Date2002-02-20
Frequency Range902-928 MHz
FRN0005037262
Test FirmNemko Dallas, Inc.
Certified ByDavida Hanson
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Submitted2002-02-20
Available2002-02-20
Created2001-12-18
Modified2001-12-18
Pages2
File TypeAdobe Acrobat PDF
File Size74606
File SHA-2566f26ecba9b530f339c3b4eebade6397d2609ebeb309245e66eee71ccc0e1df94
PDF Metadata AuthorRick Swanson
PDF Metadata ProducerAcrobat Distiller 5.0 (Windows) Rick Swanson
FCC.gov SourcesFCC.gov 226973

Related FCC Exhibits

DocumentTypeAvailableFile
USers ManualUsers Manual2002-02-20PDF 88.4 KB
Internal photosInternal Photos2002-02-20PDF 458.2 KB
External photosExternal Photos2002-02-20PDF 167.4 KB
Label detailsID Label/Location Info2002-02-20PDF 68.1 KB
Block diagramBlock Diagram2002-02-20PDF 41.7 KB
Operational descriptionOperational Description2002-02-20PDF 5.7 KB
Test setup photosTest Setup Photos2002-02-20PDF 139.8 KB
Test reportTest Report2002-06-27PDF 236.9 KB
Frequency hopping algorithmTest Report2002-02-20PDF 72.9 KB
Test reportTest Report2002-02-20PDF 852.2 KB
Change detailsCover Letter(s)2002-06-27PDF 29 KB
Confidentiality requestCover Letter(s)2002-06-27PDF 88.3 KB
Clarification letterCover Letter(s)2002-02-20PDF 18.6 KB
Request for confidentialityCover Letter(s)2002-02-20PDF 19.4 KB
Response to TCB findingsCover Letter(s)2002-02-20PDF 40.1 KB
MPE predictionRF Exposure Info2002-02-20PDF 69.7 KB
Schematics Metadata onlySchematicsPDF 160.7 KB
Frequency hopping procedure Metadata onlyOperational DescriptionPDF 68.8 KB