FCC ID PYFRDRRUG100

Ruggedized RFID Reader

by Symbol Technologies, Inc

Grantee Code: PYF   Product Code: RDRRUG100
Latest application date: 2003-10-14

FCC ID Device Details

FCC IDPYFRDRRUG100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodePYF
Product CodeRDRRUG100
Applicant BusinessSymbol Technologies, Inc 🇺🇸
Related Domains zebra.com
Equipment ClassRuggedized RFID Reader
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
909.75-921.75 MHzOriginal Equipment2003-10-14

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2003-10-14PDF 394.1 KB
internal photosInternal Photos2003-10-14PDF 482.6 KB
external photosExternal Photos2003-10-14PDF 142.5 KB
labelID Label/Location Info2003-10-14PDF 98.4 KB
Clamp Truck Reader Portal SetupOperational Description2003-10-14PDF 61.8 KB
Hyster 120 RF Cable Kit Data SheetOperational Description2003-10-14PDF 207 KB
Ruggedized Reader Data SheetOperational Description2003-10-14PDF 384.2 KB
Ruggedized Reader Power supply kit data sheetOperational Description2003-10-14PDF 328.9 KB
Teflon Linear Patch Antennas Data SheetOperational Description2003-10-14PDF 212.9 KB
test setup photosTest Setup Photos2003-10-14PDF 103.1 KB
Part 90 report revisedTest Report2003-10-14PDF 1.6 MB
Part 90 test reportTest Report2003-10-14PDF 2 MB
MET authorizationCover Letter(s)2003-10-14PDF 103.5 KB
confidentiality requestCover Letter(s)2003-10-14PDF 105.6 KB
MPE Analysis revisedRF Exposure Info2003-10-14PDF 98.2 KB
MPE calculationRF Exposure Info2003-10-14PDF 8.4 KB
Tuneup Procedure ExhibitParts List/Tune Up Info2003-10-14PDF 36 KB
duty cycle determinationRF Exposure Info2003-10-14PDF 26.5 KB
schematics Metadata onlySchematicsPDF 192.3 KB
parts list and tuneup Metadata onlyParts List/Tune Up InfoPDF 78.1 KB

Application Information

Application IDxEDTVWxGieQbKdOXanMvtg==
Final Action Date2003-10-14
Application PurposeOriginal Equipment
Applicant FRN0005037262
ModelRDRRUG100
Frequency Range909.75-921.75 MHz
Equipment ClassLMS - Part 90 Location & Monitoring Transmitter
Device DescriptionRuggedized RFID Reader
Responsible PartyQianlin Zhou, Regulatory Specialist, Larry.Zhou@zebra.com , 346-260-3543
AgentChris Chris Chris, MET Laboratories, Inc., tcbinfo@metlabs.com , 410-354-3300
Test FirmJohn Mason, MET Laboratories, Inc., jmason@metlabs.com , 410-354-3300
TCB Emailtcbinfo@metlabs.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be installed in licensed stations in such a manner that the maximum permissible exposure (MPE) limits set forth in § 1.1310 of the FCC Rules are met for both occupational/controlled exposure and for general population/uncontrolled exposure. Maximum duty cycle for this device shall not exceed 37%. The instruction manual for this device must explain that all qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. Users must be provided with the training information, antenna installation instructions, and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3) for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45cm from trained authorized operators and 100cm from all other persons. The combination of output power and antenna gain shall not exceed an effective radiated power of 30 watts.

Applications

Application IDDatePurpose
xEDTVWxGieQbKdOXanMvtg==2003-10-14Original Equipment

Equipment Authorization

FrequencyOutputEmissionRules
909.75-921.75 MHz20.0000000227KF1D90.353

Grants

TCB Grant - Application xEDTVWxGieQbKdOXanMvtg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 10/14/2003

Application Dated: 10/14/2003
Symbol Technologies, Inc
1 Zebra Plaza
Holtsville, NY 11742-1300
 
Attention: Qianlin Zhou , Regulatory Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PYFRDRRUG100
Name of Grantee:  Symbol Technologies, Inc
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: Ruggedized RFID Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 909.75  -  921.75 20.0   227KF1D

Power listed is conducted. This device must be installed in licensed stations in such a manner that the maximum permissible exposure (MPE) limits set forth in § 1.1310 of the FCC Rules are met for both occupational/controlled exposure and for general population/uncontrolled exposure. Maximum duty cycle for this device shall not exceed 37%. The instruction manual for this device must explain that all qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. Users must be provided with the training information, antenna installation instructions, and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3) for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45cm from trained authorized operators and 100cm from all other persons. The combination of output power and antenna gain shall not exceed an effective radiated power of 30 watts.

EAS Grant - Application xEDTVWxGieQbKdOXanMvtg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Symbol Technologies, Inc
1 Zebra Plaza
Holtsville, NY 11742-1300
United States
  Date of Grant: 10/14/2003

Application Dated: 10/14/2003
 
Attention: Qianlin Zhou , Regulatory Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  PYFRDRRUG100
Name of Grantee:  Symbol Technologies, Inc
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: Ruggedized RFID Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 909.75  -  921.75 20.0   227KF1D

Power listed is conducted. This device must be installed in licensed stations in such a manner that the maximum permissible exposure (MPE) limits set forth in § 1.1310 of the FCC Rules are met for both occupational/controlled exposure and for general population/uncontrolled exposure. Maximum duty cycle for this device shall not exceed 37%. The instruction manual for this device must explain that all qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. Users must be provided with the training information, antenna installation instructions, and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3) for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45cm from trained authorized operators and 100cm from all other persons. The combination of output power and antenna gain shall not exceed an effective radiated power of 30 watts.



Mail To: