FCC ID Q3QHI7260NG
Motion 7260 Module
by Xplore Technologies Corp of America
Grantee Code: Q3Q Product Code: HI7260NG
Latest application date: 2014-10-08
FCC ID Device Details
| FCC ID | Q3QHI7260NG |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | Q3Q |
| Product Code | HI7260NG |
| Applicant Business | Xplore Technologies Corp of America 🇺🇸 |
| Related Domains | |
| Equipment Class | Motion 7260 Module |
| Test Firm | Bay Area Compliance Laboratories Corporation |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2014-10-08 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2014-10-08 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2014-10-08 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 | 2014-10-01 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 | 2014-10-01 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 | 2014-10-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Host Photos | External Photos | 2014-10-08 | PDF 337.1 KB |
| Ext Photos | External Photos | 2014-10-01 | PDF 127.1 KB |
| Host Label | ID Label/Location Info | 2014-10-08 | PDF 1.1 MB |
| Host Label | ID Label/Location Info | 2014-10-08 | PDF 1.1 MB |
| Host Label | ID Label/Location Info | 2014-10-08 | PDF 1.1 MB |
| FCC ID Label | ID Label/Location Info | 2014-10-01 | PDF 157.8 KB |
| CIIPC Letter | Cover Letter(s) | 2014-10-08 | PDF 80.2 KB |
| POA | Cover Letter(s) | 2014-10-08 | PDF 36 KB |
| Authorization Letter from Original Grantee | Cover Letter(s) | 2014-10-01 | PDF 16.9 KB |
| Change in ID Application Letter | Cover Letter(s) | 2014-10-01 | PDF 39.6 KB |
| POA | Cover Letter(s) | 2014-10-01 | PDF 38.9 KB |
| SAR Report Metadata only | RF Exposure Info | 2014-10-08 | PDF 4.6 MB |
| SAR Report Rev | RF Exposure Info | 2014-10-08 | PDF 4.6 MB |
| SAR Report Rev | RF Exposure Info | 2014-10-08 | PDF 4.6 MB |
Application Information
| Application ID | tCmUDDKqYCbUZGG0qEBgtQ== |
|---|---|
| Final Action Date | 2014-10-08 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0009692500 |
| Model | HI7260NG |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Motion 7260 Module |
| Responsible Party | David J Ball, Senior Regulatory and Compliance Specialist, dball@xploretech.com |
| Test Firm | Lisa Tang, Bay Area Compliance Laboratories Corporation, lisat@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz and 5.470-5.725 GHz bands. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR for body and simultaneous transmission conditions are 1.57 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| tCmUDDKqYCbUZGG0qEBgtQ== | 2014-10-08 | Class II permissive change or modification of presently authorized equipment |
| cdMMttkJbix/LKGaPx5d8A== | 2014-10-08 | Class II permissive change or modification of presently authorized equipment |
| 5f/uUUK+gRJMkmByR55JtA== | 2014-10-08 | Class II permissive change or modification of presently authorized equipment |
| xEQrqNtd87ONhVX8swTKnA== | 2014-10-01 | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 |
| c2jOycj/9DegmV/NQpYc5A== | 2014-10-01 | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 |
| UaHHTtAqSKhVwTdjncmGgg== | 2014-10-01 | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 |
| Edj1QXs+MpGpMCVdNQQ+xw== | 2014-10-01 | Change in identification of presently authorized equipment. Original FCC ID: PD97260NG Grant Date: 04/17/2013 |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 15B | CC | ||
| 2402-2480 MHz | 0.0050000 | 15C | CC |
| 2402-2480 MHz | 0.006 | 15C | CC |
| 2412-2462 MHz | 0.316 | 15C | CC, MO |
| 2422-2452 MHz | 0.347 | 15C | CC, MO |
| 5180-5240 MHz | 0.036 | 15E | CC, MO |
| 5190-5230 MHz | 0.037 | 15E | CC, MO |
| 5260-5320 MHz | 0.038 | 15E | CC, MO, ND |
| 5500-5700 MHz | 0.046 | 15E | CC, MO, ND |
| 5510-5670 MHz | 0.046 | 15E | CC, MO, ND |
| 5530-5690 MHz | 0.046 | 15E | CC, MO, ND |
| 5710 MHz | 0.038 | 15E | CC, MO, ND |
| 5720 MHz | 0.036 | 15E | CC, MO, ND |
| 5745-5825 MHz | 0.355 | 15C | CC, MO |
| 5755-5795 MHz | 0.174 | 15C | CC, MO |
Grants
TCB Grant - Application xEQrqNtd87ONhVX8swTKnA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application xEQrqNtd87ONhVX8swTKnA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Digital Transmission System |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.006 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.316 | ||
| CC MO | 15C | 2422.0 - 2452.0 | 0.347 | ||
| CC MO | 15C | 5745.0 - 5825.0 | 0.355 | ||
| CC MO | 15C | 5755.0 - 5795.0 | 0.174 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest measured body SAR value at 8mm antenna-to-user separation distance in Laptop/Notebook/Netbook and Tablet Computer hosts is: 0.55 W/kg. Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application UaHHTtAqSKhVwTdjncmGgg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Digital Transmission System |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.006 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.316 | ||
| CC MO | 15C | 2422.0 - 2452.0 | 0.347 | ||
| CC MO | 15C | 5745.0 - 5825.0 | 0.355 | ||
| CC MO | 15C | 5755.0 - 5795.0 | 0.174 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest measured body SAR value at 8mm antenna-to-user separation distance in Laptop/Notebook/Netbook and Tablet Computer hosts is: 0.55 W/kg. Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.036 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.037 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.038 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.046 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.046 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.038 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.036 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.046 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz and 5.470-5.725 GHz bands. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR for body and simultaneous transmission conditions are 1.57 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application tCmUDDKqYCbUZGG0qEBgtQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.036 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.037 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.038 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.046 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.046 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.038 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.036 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.046 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz and 5.470-5.725 GHz bands. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR for body and simultaneous transmission conditions are 1.57 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.036 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.037 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.038 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.046 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.046 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.038 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.036 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.046 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz and 5.470-5.725 GHz bands. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest measured body SAR value at 8mm antenna-to-user separation distance in Laptop/Notebook/Netbook and Tablet Computer hosts is: 0.76 W/kg. Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application Edj1QXs+MpGpMCVdNQQ+xw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.036 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.037 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.038 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.046 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.046 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.038 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.036 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.046 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz and 5.470-5.725 GHz bands. Device is a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest measured body SAR value at 8mm antenna-to-user separation distance in Laptop/Notebook/Netbook and Tablet Computer hosts is: 0.76 W/kg. Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Digital Transmission System |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.006 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.316 | ||
| CC MO | 15C | 2422.0 - 2452.0 | 0.347 | ||
| CC MO | 15C | 5745.0 - 5825.0 | 0.355 | ||
| CC MO | 15C | 5755.0 - 5795.0 | 0.174 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a 2x2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR for body and simultaneous transmission conditions are 1.54 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application cdMMttkJbix/LKGaPx5d8A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Digital Transmission System |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.006 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.316 | ||
| CC MO | 15C | 2422.0 - 2452.0 | 0.347 | ||
| CC MO | 15C | 5745.0 - 5825.0 | 0.355 | ||
| CC MO | 15C | 5755.0 - 5795.0 | 0.174 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this device must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a 2x2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrators must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR for body and simultaneous transmission conditions are 1.54 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval filing, the antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application c2jOycj/9DegmV/NQpYc5A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/01/2014 Application Dated: 10/01/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Change in ID application documented in this filing. Power Output listed is conducted. Modular Approval filing, the antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR Simultaneous TX: 1.02 W/kg with separation ratio of 0.02 at 50mm antenna-to-antenna separation. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Xplore Technologies Corp of America |
| 14000 Summit Dr., Suite 900 |
| Austin, TX 78728 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Power Output listed is conducted. Modular Approval filing, the antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR for body and simultaneous transmission conditions are 0.03 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 5f/uUUK+gRJMkmByR55JtA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Xplore Technologies Corp of America 14000 Summit Dr., Suite 900 Austin, TX 78728 United States |
Date of Grant: 10/08/2014 Application Dated: 10/08/2014 |
| Attention: David Ball , Senior Regulatory and Compliance Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q3QHI7260NG |
| Name of Grantee: | Xplore Technologies Corp of America |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Motion 7260 Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Power Output listed is conducted. Modular Approval filing, the antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR for body and simultaneous transmission conditions are 0.03 W/kg, and 1.59 W/kg respectively. This change is to request approval for portable category specific Motion tablet PC, model number: FWS-002. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |