FCC ID Q3QHWNVWUNDP-1

Tablet PC with Wireless Wide Area Network Module

by Xplore Technologies Corp of America

Grantee Code: Q3Q   Product Code: HWNVWUNDP1
Latest application date: 2009-05-04

FCC ID Device Details

FCC IDQ3QHWNVWUNDP-1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQ3Q
Product CodeHWNVWUNDP1
Applicant BusinessXplore Technologies Corp of America 🇺🇸
Related Domains xploretech.com
Equipment ClassTablet PC with Wireless Wide Area Network Module
Test FirmBay Area Compliance Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2009-05-04
824.2-848.8 MHzOriginal Equipment2009-04-13

Exhibits

DocumentTypeAvailableFile
Regulatory GuideUsers Manual2009-05-04PDF 477.7 KB
Users GuideUsers Manual2009-05-04PDF 1.7 MB
Internal PhotosInternal Photos2009-05-04PDF 668.9 KB
External PhotosExternal Photos2009-05-04PDF 764.2 KB
ID and Label DrwngID Label/Location Info2009-05-04PDF 1.1 MB
Setup photosTest Setup Photos2009-05-04PDF 254 KB
RF Test ReportTest Report2009-05-04PDF 325.4 KB
SAR Test ReportTest Report2009-05-04PDF 3.7 MB
Attestation LetterAttestation Statements2009-05-04PDF 56.5 KB
Authorization LetterCover Letter(s)2009-05-04PDF 14.4 KB
Confidentiality RequestCover Letter(s)2009-05-04PDF 80.5 KB
Confidential Request LetterCover Letter(s)PDF 80.5 KB

Application Information

Application IDbiMcVmJNzc5Z56CS0226dA==
Final Action Date2009-05-04
Application PurposeOriginal Equipment
Applicant FRN0009692500
ModelHWNVWUNDP-1
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionTablet PC with Wireless Wide Area Network Module
Responsible PartyDavid J Ball, Senior Regulatory and Compliance Specialist, dball@xploretech.com , 512-485-1556
Test FirmJohn Chan, Bay Area Compliance Laboratory, bacl.regulatory@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power listed is conducted; highest radiated power measured in specific configurations shown in this filing is Part 22H ERP: 2.254 W, Part 24E EIRP: 0.861W. This device is authorized to operate with the specific computer described in this filing. This transmitter may not operate simultaneously with any other collocated transmitter or antenna except in accordance with FCC multi-transmitter product procedures. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported body SAR values as described in this filing are: Part 22H: 0.537 W/Kg, Part 24E: 0.860 W/Kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

Applications

Application IDDatePurpose
biMcVmJNzc5Z56CS0226dA==2009-05-04Original Equipment
LCrST+zzvLqrL0eaupAipg==2009-04-13Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.8322.5ppm248KGXW22H
824.2-848.8 MHz1.9862.5ppm248KGXW22H
824.2-848.8 MHz0.5312.5ppm248KG7W22H
824.2-848.8 MHz0.6072.5ppm248KG7W22H
824.7-848.31 MHz0.2912.5ppm1M28F9W22H
824.7-848.31 MHz0.312.5ppm1M28F9W22H
826.4-846.6 MHz0.2642.5ppm4M18F9W22H
826.4-846.6 MHz0.2772.5ppm4M18F9W22H
1850.2-1909.8 MHz0.8732.5ppm250KGXW24E
1850.2-1909.8 MHz0.8852.5ppm250KGXW24E
1850.2-1909.8 MHz0.3942.5ppm245KG7W24E
1850.2-1909.8 MHz0.482.5ppm245KG7W24E
1851.25-1908.75 MHz0.2762.5ppm1M28F9W24E
1851.25-1908.75 MHz0.2892.5ppm1M28F9W24E
1852.4-1907.6 MHz0.272.5ppm4M19F9W24E
1852.4-1907.5 MHz0.2862.5ppm4M19F9W24E

Grants

TCB Grant - Application LCrST+zzvLqrL0eaupAipg==

This application does not exist.

EAS Grant - Application LCrST+zzvLqrL0eaupAipg==

This application currently is not in final status.

TCB Grant - Application biMcVmJNzc5Z56CS0226dA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 05/04/2009

Application Dated: 05/04/2009
Xplore Technologies Corp of America
14000 Summit Dr., Suite 900
Austin, TX 78728
 
Attention: David Ball , Senior Regulatory and Compliance Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q3QHWNVWUNDP-1
Name of Grantee:  Xplore Technologies Corp of America
Equipment Class: PCS Licensed Transmitter
Notes: Tablet PC with Wireless Wide Area Network Module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.832 2.5  PM 248KGXW
22H 824.2  -  848.8 0.531 2.5  PM 248KG7W
22H 826.4  -  846.6 0.264 2.5  PM 4M18F9W
22H 824.7  -  848.31 0.291 2.5  PM 1M28F9W
24E 1850.2  -  1909.8 0.873 2.5  PM 250KGXW
24E 1850.2  -  1909.8 0.394 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.27 2.5  PM 4M19F9W
24E 1851.25  -  1908.75 0.276 2.5  PM 1M28F9W

Output power listed is conducted; highest radiated power measured in specific configurations shown in this filing is Part 22H ERP: 2.254 W, Part 24E EIRP: 0.861W. This device is authorized to operate with the specific computer described in this filing. This transmitter may not operate simultaneously with any other collocated transmitter or antenna except in accordance with FCC multi-transmitter product procedures. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported body SAR values as described in this filing are: Part 22H: 0.537 W/Kg, Part 24E: 0.860 W/Kg.

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.


EAS Grant - Application biMcVmJNzc5Z56CS0226dA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Xplore Technologies Corp of America
14000 Summit Dr., Suite 900
Austin, TX 78728
United States
  Date of Grant: 05/04/2009

Application Dated: 05/04/2009
 
Attention: David Ball , Senior Regulatory and Compliance Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q3QHWNVWUNDP-1
Name of Grantee:  Xplore Technologies Corp of America
Equipment Class: PCS Licensed Transmitter
Notes: Tablet PC with Wireless Wide Area Network Module
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.832 2.5  PM 248KGXW
22H 824.2  -  848.8 0.531 2.5  PM 248KG7W
22H 826.4  -  846.6 0.264 2.5  PM 4M18F9W
22H 824.7  -  848.31 0.291 2.5  PM 1M28F9W
24E 1850.2  -  1909.8 0.873 2.5  PM 250KGXW
24E 1850.2  -  1909.8 0.394 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.27 2.5  PM 4M19F9W
24E 1851.25  -  1908.75 0.276 2.5  PM 1M28F9W

Output power listed is conducted; highest radiated power measured in specific configurations shown in this filing is Part 22H ERP: 2.254 W, Part 24E EIRP: 0.861W. This device is authorized to operate with the specific computer described in this filing. This transmitter may not operate simultaneously with any other collocated transmitter or antenna except in accordance with FCC multi-transmitter product procedures. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported body SAR values as described in this filing are: Part 22H: 0.537 W/Kg, Part 24E: 0.860 W/Kg.

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.



Mail To: