FCC ID Q5EPT650002

Two-way Radio

by Shenzhen Kirisun Communications Co., Ltd.

Grantee Code: Q5E   Product Code: PT650002
Latest application date: 2007-11-19

FCC ID Device Details

FCC IDQ5EPT650002
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQ5E
Product CodePT650002
Applicant BusinessShenzhen Kirisun Communications Co., Ltd. 🇨🇳
Related Domains szkirisun.com kirisun.com
Equipment ClassTwo-way Radio
Test FirmShenzhen Academy of Metrology & Quality Inspection

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
406.1-454 MHzOriginal Equipment2007-11-19

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2007-11-19PDF 540.7 KB
Internal PhotosInternal Photos2007-11-19PDF 601.9 KB
External PhotosExternal Photos2007-11-19PDF 314.2 KB
Label Location InfoID Label/Location Info2007-11-19PDF 167.6 KB
Operational DescriptionOperational Description2007-11-19PDF 28.6 KB
Test Setup photosTest Setup Photos2007-11-19PDF 471.4 KB
Test ReportTest Report2007-11-19PDF 1.9 MB
commentsCover Letter(s)2007-11-19PDF 69.3 KB
confidentiality request letterCover Letter(s)2007-11-19PDF 33 KB
MPE reportRF Exposure Info2007-11-19PDF 6.7 KB
Parts ListParts List/Tune Up Info2007-11-19PDF 46.5 KB
Tune Up InfoParts List/Tune Up Info2007-11-19PDF 9.5 KB

Application Information

Application IDE1XNJq+DNVnvWcVkTEAytQ==
Final Action Date2007-11-19
Application PurposeOriginal Equipment
Applicant FRN0008873473
ModelPT650002
Frequency Range406.1-454 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionTwo-way Radio
Responsible PartyJessica Wang, Manager, jessica.wang@szkirisun.com , 755-86095979
Technical ContactPeter, Shenzhen Academy of metrelogy & quality inspection, linb@smq.com.cn , +86-755 26941599
Non-Technical ContactXin Chen, KIRISUN ELECTRONICS(SHENZHEN)COz, RD@KIRISUN.COM , 0755-86096055
Test FirmPeter Lin, Shenzhen Academy of Metrology & Quality Inspection, peter_lin@cmmail.com , 86-755-6941635
TCB Emailhotline@atcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower is conducted at the antenna terminal. This transmitter must operate in push-to-talk mode with a duty factor not exceeding 50%. This transmitter is restricted to work related operations in an Occupational/Controlled RF exposure Environment, and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter may not be used in any body worn configuration. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with ccupational/Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

Applications

Application IDDatePurpose
E1XNJq+DNVnvWcVkTEAytQ==2007-11-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
406.1-454 MHz3.812.5ppm11K3F3E9
456-470 MHz3.815ppm16K8F3E9

Grants

TCB Grant - Application E1XNJq+DNVnvWcVkTEAytQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 11/19/2007

Application Dated: 11/06/2007
Kirisun Communications Co., Ltd
3-6F ROBETA Building, No. 1, QiMin Road,Song Ping
Shan Area,Science & Industry Park,Nanshan District
Shenzhen, 518057
China
 
Attention: Jessica Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q5EPT650002
Name of Grantee:  Kirisun Communications Co., Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Two-way Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 406.1  -  454.0 3.81 2.5  PM 11K3F3E
90 456.0  -  470.0 3.81 5.0  PM 16K8F3E

Power is conducted at the antenna terminal. This transmitter must operate in push-to-talk mode with a duty factor not exceeding 50%. This transmitter is restricted to work related operations in an Occupational/Controlled RF exposure Environment, and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter may not be used in any body worn configuration. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with ccupational/Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

EAS Grant - Application E1XNJq+DNVnvWcVkTEAytQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kirisun Communications Co., Ltd
3-6F ROBETA Building, No. 1, QiMin Road,Song Ping Shan Area,Science & Industry Park,Nanshan District
Shenzhen, 518057
China
  Date of Grant: 11/19/2007

Application Dated: 11/06/2007
 
Attention: Jessica Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q5EPT650002
Name of Grantee:  Kirisun Communications Co., Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Two-way Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 406.1  -  454.0 3.81 2.5  PM 11K3F3E
90 456.0  -  470.0 3.81 5.0  PM 16K8F3E

Power is conducted at the antenna terminal. This transmitter must operate in push-to-talk mode with a duty factor not exceeding 50%. This transmitter is restricted to work related operations in an Occupational/Controlled RF exposure Environment, and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter may not be used in any body worn configuration. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with ccupational/Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.



Mail To: