FCC ID Q828504HI0001000

GSM850 NanoCell

by Telephonics Wireless Corporation

Grantee Code: Q82   Product Code: 8504HI0001000
Latest application date: 2004-05-30

FCC ID Device Details

FCC IDQ828504HI0001000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQ82
Product Code8504HI0001000
Applicant BusinessTelephonics Wireless Corporation 🇺🇸
Related Domains twcfl.com
Equipment ClassGSM850 NanoCell
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2004-05-30

Exhibits

DocumentTypeAvailableFile
users manaulUsers Manual2004-05-30PDF 961.6 KB
internal photosInternal Photos2004-05-30PDF 1.1 MB
external photosExternal Photos2004-05-30PDF 399.6 KB
label and locationID Label/Location Info2004-05-30PDF 40.5 KB
test reportTest Report2004-05-30PDF 424.7 KB
Letter of AuthorizationCover Letter(s)2004-05-30PDF 659.5 KB
Letter of confidentialityCover Letter(s)2004-05-30PDF 664.5 KB
tuneup procedureParts List/Tune Up Info2004-05-30PDF 657 KB
block diagrams Metadata onlyBlock DiagramPDF 40.7 KB
BBP SCH REVA 21 Metadata onlySchematicsPDF 473.2 KB
Backplane Sch Metadata onlySchematicsPDF 70.2 KB
NCP Sch Metadata onlySchematicsPDF 591.2 KB
REF OSC Rev Metadata onlySchematicsPDF 93.8 KB
rffe sch Metadata onlySchematicsPDF 151.2 KB
rx nbts Metadata onlySchematicsPDF 325.4 KB
rx nms Metadata onlySchematicsPDF 333.6 KB
tx nbts Metadata onlySchematicsPDF 386 KB
tx nms Metadata onlySchematicsPDF 378.3 KB
21033 info dc power Metadata onlyOperational DescriptionPDF 59.6 KB
product description Metadata onlyOperational DescriptionPDF 931 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 61.3 KB

Application Information

Application IDkQSr5o+Nn/fhZY6gflb/nQ==
Final Action Date2004-05-30
Application PurposeOriginal Equipment
Applicant FRN0008412009
Model8504HI0001000
Frequency Range824.2-848.8 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionGSM850 NanoCell
Responsible PartyGary Matthews, President, matthews@twcfl.com , 321-757-8254
Test FirmRobert Frier, MET Laboratories, Inc., rfrier@metlabs.com , 4103543300
TCB Emailtcbinfo@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is Conducted. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The upper channel in each block is a guard band.

Applications

Application IDDatePurpose
kQSr5o+Nn/fhZY6gflb/nQ==2004-05-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz310Hz245KGXW22BC
869.4-893.6 MHz0.2610Hz248KGXW22BC

Grants

TCB Grant - Application kQSr5o+Nn/fhZY6gflb/nQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 05/30/2004

Application Dated: 05/30/2004
Telephonics Wireless Corporation
2290 W. Eau Gallie Blvd. Suite 110
Melbourne, FL 32935
 
Attention: Gary Matthews , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q828504HI0001000
Name of Grantee:  Telephonics Wireless Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: GSM850 NanoCell
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22 824.2  -  848.8 3.0 10.0  Hz 245KGXW
BC 22 869.4  -  893.6 0.26 10.0  Hz 248KGXW

Output Power is Conducted. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The upper channel in each block is a guard band.

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application kQSr5o+Nn/fhZY6gflb/nQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Telephonics Wireless Corporation
2290 W. Eau Gallie Blvd. Suite 110
Melbourne, FL 32935
United States
  Date of Grant: 05/30/2004

Application Dated: 05/30/2004
 
Attention: Gary Matthews , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q828504HI0001000
Name of Grantee:  Telephonics Wireless Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: GSM850 NanoCell
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22 824.2  -  848.8 3.0 10.0  Hz 245KGXW
BC 22 869.4  -  893.6 0.26 10.0  Hz 248KGXW

Output Power is Conducted. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The upper channel in each block is a guard band.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: