FCC ID Q87-WUSB6400M

Linksys Dual-Band Wireless-AC USB Adapter

by LINKSYS LLC

Grantee Code: Q87   Product Code: WUSB6400M
Latest application date: 2017-03-29

Device Images

FCC ID Device Details

FCC IDQ87-WUSB6400M
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQ87
Product CodeWUSB6400M
Applicant BusinessLINKSYS LLC 🇺🇸
Related Domains belkin.com
Equipment ClassLinksys Dual-Band Wireless-AC USB Adapter
Test FirmBureau Veritas CPS(H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2017-03-29
2412-2462 MHzOriginal Equipment2017-03-29

Exhibits

DocumentTypeAvailableFile
User Manual (Statement) rev 2.pdfUsers Manual2017-03-29PDF 511.6 KB
User Manual.pdfUsers Manual2017-03-29PDF 224.3 KB
Internal Photos rev.pdfInternal Photos2017-03-29PDF 820 KB
External Photos.pdfExternal Photos2017-03-29PDF 193.4 KB
Label Location.pdfID Label/Location Info2017-03-29PDF 23.7 KB
Label Sample rev.pdfID Label/Location Info2017-03-29PDF 1.5 MB
Test Setup Photo (SAR) rev.pdfTest Setup Photos2017-03-29PDF 702.4 KB
Test Setup Photo (SAR).pdf Metadata onlyTest Setup Photos2017-03-29PDF 471.2 KB
Test Setup Photo.pdfTest Setup Photos2017-03-29PDF 294.4 KB
Test Report_2.4G rev 2.pdfTest Report2017-03-29PDF 1.3 MB
Test Report_5G rev 2.pdfTest Report2017-03-29PDF 915.6 KB
Test Report_DFS rev.pdfTest Report2017-03-29PDF 407.5 KB
Attestation - Channel and Mode Declaration.pdfAttestation Statements2017-03-29PDF 197.5 KB
Attestation - DFS Declaration rev.pdfAttestation Statements2017-03-29PDF 264.8 KB
Cover Letter - Agent Authorization.pdfCover Letter(s)2017-03-29PDF 208 KB
Cover Letter - Confidentiality Request - Long Term.pdfCover Letter(s)2017-03-29PDF 198.3 KB
RF Exposure Information (SAR) Part 1.pdf Metadata onlyRF Exposure Info2017-03-29PDF 1.5 MB
RF Exposure Information (SAR) Part 2.pdf Metadata onlyRF Exposure Info2017-03-29PDF 5 MB
RF Exposure Information (SAR) rev.pdfRF Exposure Info2017-03-29PDF 4.7 MB
Operational Description.pdf Metadata onlyInternal PhotosPDF 20.5 KB
Block Diagram rev.pdf Metadata onlyBlock DiagramPDF 443.2 KB
Schematics rev.pdf Metadata onlySchematicsPDF 482.7 KB
Operational Description.pdf Metadata onlyOperational DescriptionPDF 20.5 KB
Operational description - KDB 791906.pdf Metadata onlyOperational DescriptionPDF 154.3 KB
Operational description - Test Plan.pdf Metadata onlyOperational DescriptionPDF 640.7 KB
Software Operation Description rev.pdf Metadata onlyOperational DescriptionPDF 329.7 KB

Application Information

Application IDbm6/amhvTPFs/GoMFO+VcQ==
Final Action Date2017-03-29
Application PurposeOriginal Equipment
Applicant FRN0009100470
ModelWUSB6400M
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionLinksys Dual-Band Wireless-AC USB Adapter
Responsible PartyPo-Wen Cheng, Regulatory Compliance Manager, Po-Wen.Cheng@Belkin.com , 949-238-4518
AgentEmily Emily Emily, Bureau Veritas Consumer Products Services (H.K.) L, emily.lin@tw.bureauveritas.com
Test FirmRichard Chen, Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com , +886-(0)3-260-0884
TCB Emailtcb@us.bureauveritas.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower listed is the maximum combined conducted output power. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. The device has been tested and meets FCC RF exposure guidelines when used and positioned with a minimum of 5 mm from the body. The highest reported SAR for body use condition is 1.17 W/kg. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. This device has 20, 40, and 80 MHz bandwidth modes.

Applications

Application IDDatePurpose
bm6/amhvTPFs/GoMFO+VcQ==2017-03-29Original Equipment
1vtmAWjlArOdLPGp9kj9Qg==2017-03-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.374000015CCC, MO
5180-5240 MHz0.04615E38, CC, MO
5260-5320 MHz0.04815E38, CC, MO, ND
5500-5700 MHz0.04615E38, CC, MO, ND
5745-5825 MHz0.04915E38, CC, MO

Grants

TCB Grant - Application bm6/amhvTPFs/GoMFO+VcQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 03/29/2017

Application Dated: 03/13/2017
LINKSYS LLC
121 Theory Drive
Irvine, CA 92617
 
Attention: Po-Wen Cheng , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q87-WUSB6400M
Name of Grantee:  LINKSYS LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Linksys Dual-Band Wireless-AC USB Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.046  
38 CC MO ND 15E 5260.0  -  5320.0 0.048  
38 CC MO ND 15E 5500.0  -  5700.0 0.046  
38 CC MO 15E 5745.0  -  5825.0 0.049  

Power listed is the maximum combined conducted output power. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. The device has been tested and meets FCC RF exposure guidelines when used and positioned with a minimum of 5 mm from the body. The highest reported SAR for body use condition is 1.17 W/kg. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. This device has 20, 40, and 80 MHz bandwidth modes.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application bm6/amhvTPFs/GoMFO+VcQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LINKSYS LLC
121 Theory Drive
Irvine, CA 92617
United States
  Date of Grant: 03/29/2017

Application Dated: 03/13/2017
 
Attention: Po-Wen Cheng , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q87-WUSB6400M
Name of Grantee:  LINKSYS LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Linksys Dual-Band Wireless-AC USB Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.046  
38 CC MO ND 15E 5260.0  -  5320.0 0.048  
38 CC MO ND 15E 5500.0  -  5700.0 0.046  
38 CC MO 15E 5745.0  -  5825.0 0.049  

Power listed is the maximum combined conducted output power. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. The device has been tested and meets FCC RF exposure guidelines when used and positioned with a minimum of 5 mm from the body. The highest reported SAR for body use condition is 1.17 W/kg. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. This device has 20, 40, and 80 MHz bandwidth modes.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application 1vtmAWjlArOdLPGp9kj9Qg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 03/29/2017

Application Dated: 03/13/2017
LINKSYS LLC
121 Theory Drive
Irvine, CA 92617
 
Attention: Po-Wen Cheng , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q87-WUSB6400M
Name of Grantee:  LINKSYS LLC
Equipment Class: Digital Transmission System
Notes: Linksys Dual-Band Wireless-AC USB Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.374  

Power listed is the maximum combined conducted output power. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. The device has been tested and meets FCC RF exposure guidelines when used and positioned with a minimum of 5 mm from the body. The highest reported SAR for body use condition is 0.92W/kg. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. This device has 20 and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 1vtmAWjlArOdLPGp9kj9Qg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LINKSYS LLC
121 Theory Drive
Irvine, CA 92617
United States
  Date of Grant: 03/29/2017

Application Dated: 03/13/2017
 
Attention: Po-Wen Cheng , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Q87-WUSB6400M
Name of Grantee:  LINKSYS LLC
Equipment Class: Digital Transmission System
Notes: Linksys Dual-Band Wireless-AC USB Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.374  

Power listed is the maximum combined conducted output power. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. The device has been tested and meets FCC RF exposure guidelines when used and positioned with a minimum of 5 mm from the body. The highest reported SAR for body use condition is 0.92W/kg. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. This device has 20 and 40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: