FCC ID Q8KPCSHW70A
Bi-directional booster
by G-Way Solutions, LLC
Grantee Code: Q8K Product Code: PCSHW70A
Latest application date: 2004-06-29
FCC ID Device Details
| FCC ID | Q8KPCSHW70A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | Q8K |
| Product Code | PCSHW70A |
| Applicant Business | G-Way Solutions, LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Bi-directional booster |
| Test Firm | Nemko Canada Inc. (Ottawa) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850-1910 MHz | Original Equipment | 2004-06-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| manual | Users Manual | 2004-06-29 | PDF 1.2 MB |
| user manual | Users Manual | 2004-06-29 | PDF 382 KB |
| INTERNAL PHOTOS | Internal Photos | 2004-06-29 | PDF 274 KB |
| EXTERNAL PHOTO | External Photos | 2004-06-29 | PDF 193 KB |
| label format and location | ID Label/Location Info | 2004-06-29 | PDF 227.9 KB |
| test setup photos | Test Setup Photos | 2004-06-29 | PDF 180.6 KB |
| Test report | Test Report | 2004-06-29 | PDF 507.4 KB |
| band rejection data | Test Report | 2004-06-29 | PDF 400.2 KB |
| upink data | Test Report | 2004-06-29 | PDF 539.7 KB |
| Authority to act as agent | Cover Letter(s) | 2004-06-29 | PDF 41.4 KB |
| Confidentiality request | Cover Letter(s) | 2004-06-29 | PDF 39.3 KB |
| Cover letter Downlink test only | Cover Letter(s) | 2004-06-29 | PDF 38.9 KB |
| Model difference letter | Cover Letter(s) | 2004-06-29 | PDF 83.8 KB |
| MPE PCS C | RF Exposure Info | 2004-06-29 | PDF 26 KB |
| MPE PCS E | RF Exposure Info | 2004-06-29 | PDF 26.5 KB |
| output biasing | Parts List/Tune Up Info | 2004-06-29 | PDF 57.4 KB |
| tune up procedure | Parts List/Tune Up Info | 2004-06-29 | PDF 128.3 KB |
| SCHEMATICS Metadata only | Schematics | PDF 104.3 KB | |
| circuit description Metadata only | Operational Description | PDF 106.5 KB | |
| specs Metadata only | Operational Description | PDF 73.8 KB | |
| PARTS LIST Metadata only | Parts List/Tune Up Info | PDF 64 KB |
Application Information
| Application ID | Ph8/cK5K4NodHVTS/Yu45A== |
|---|---|
| Final Action Date | 2004-06-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0009113457 |
| Model | PCSHW70A |
| Frequency Range | 1850-1910 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Bi-directional booster |
| Responsible Party | Sharon David, Marketing Director, tech-support@gwaverf.com |
| Technical Contact | Dino Giordano, G-Wave Inc., dino_g@gwaverf.com |
| Non-Technical Contact | Adrian Kofler, G-Wave Inc., adrian_k@gwaverf.com |
| Test Firm | Charles Neal, Nemko Canada Inc. (Ottawa), charles.neal@nemko.com |
| TCB Email | ruby.dulmage@nemko.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Downlink (Indoor Antenna) The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi for MPE compliance. Uplink (Outdoor Antenna) The antenna used for this transmitter is to be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Power output listed is composite for multi-channel operation. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Ph8/cK5K4NodHVTS/Yu45A== | 2004-06-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application Ph8/cK5K4NodHVTS/Yu45A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 06/29/2004 Application Dated: 06/29/2004 |
| G-Way Solutions, LLC |
| 38 Leuning Street |
| South Hackensack, NJ 07606 |
| Attention: Sharon David , Marketing Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q8KPCSHW70A |
| Name of Grantee: | G-Way Solutions, LLC |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Bi-directional booster |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | DXW | |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | F9W | |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | DXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | F9W |
| Downlink (Indoor Antenna) The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi for MPE compliance. Uplink (Outdoor Antenna) The antenna used for this transmitter is to be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Power output listed is composite for multi-channel operation. |
EAS Grant - Application Ph8/cK5K4NodHVTS/Yu45A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
G-Way Solutions, LLC 38 Leuning Street South Hackensack, NJ 07606 United States |
Date of Grant: 06/29/2004 Application Dated: 06/29/2004 |
| Attention: Sharon David , Marketing Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Q8KPCSHW70A |
| Name of Grantee: | G-Way Solutions, LLC |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Bi-directional booster |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | DXW | |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | F9W | |
| 24E | 1850.0 - 1910.0 | 0.063 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | DXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.063 | Amp | F9W |
| Downlink (Indoor Antenna) The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). The maximum allowed antenna gain is 2 dBi for MPE compliance. Uplink (Outdoor Antenna) The antenna used for this transmitter is to be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Power output listed is composite for multi-channel operation. |
| Mail To: |