FCC ID QDJ-0602DBS01

Smart Phone

by Chi Mei Communication Systems, Inc.

Grantee Code: QDJ   Product Code: 0602DBS01
Latest application date: 2006-06-14

FCC ID Device Details

FCC IDQDJ-0602DBS01
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQDJ
Product Code0602DBS01
Applicant BusinessChi Mei Communication Systems, Inc. 🇹🇼
Related Domains fihtdc.com tp.cmcs.com.tw
Equipment ClassSmart Phone
Test FirmSPORTON International Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2006-06-14
824.2-848.8 MHzOriginal Equipment2006-06-14
2402-2480 MHzOriginal Equipment2006-06-14

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2006-06-14PDF 2.5 MB
Revised ManualUsers Manual2006-06-14PDF 2.6 MB
Int PhotosInternal Photos2006-06-14PDF 326.9 KB
InternalInternal Photos2006-06-14PDF 326.9 KB
SampleInternal Photos2006-06-14PDF 119.7 KB
Ext PhotosExternal Photos2006-06-14PDF 222.8 KB
ExternalExternal Photos2006-06-14PDF 222.8 KB
LocationID Label/Location Info2006-06-14PDF 133.8 KB
SampleID Label/Location Info2006-06-14PDF 119.7 KB
15C Test SetupTest Setup Photos2006-06-14PDF 207.5 KB
Test Setup Part 22 24Test Setup Photos2006-06-14PDF 117.5 KB
15C Part 1Test Report2006-06-14PDF 650.7 KB
15C Part 2Test Report2006-06-14PDF 2.4 MB
15C Part 3Test Report2006-06-14PDF 2.7 MB
15C Test Report Part 1Test Report2006-06-14PDF 650.7 KB
15C Test Report Part 2Test Report2006-06-14PDF 2.4 MB
15C Test Report Part 3Test Report2006-06-14PDF 2.7 MB
Part 22 24 Test ReportTest Report2006-06-14PDF 671.8 KB
Confid RequestCover Letter(s)2006-06-14PDF 101 KB
BT RF ExposureRF Exposure Info2006-06-14PDF 30.4 KB
DTS SARRF Exposure Info2006-06-14PDF 2.8 MB
Revised RF ExposureRF Exposure Info2006-06-14PDF 2.8 MB
Revised SARRF Exposure Info2006-06-14PDF 2.8 MB
Revised SAR ReportRF Exposure Info2006-06-14PDF 2.8 MB
SAR Part 1RF Exposure Info2006-06-14PDF 1.9 MB
SAR Part 2RF Exposure Info2006-06-14PDF 2.3 MB
Block Metadata onlyBlock DiagramPDF 163.4 KB
Schema Metadata onlySchematicsPDF 516 KB
Op Descript Metadata onlyOperational DescriptionPDF 276.6 KB
Op Description Metadata onlyOperational DescriptionPDF 276.6 KB
Revised Ops Metadata onlyOperational DescriptionPDF 284.9 KB
Parts Metadata onlyParts List/Tune Up InfoPDF 16.9 KB
Tune Up Metadata onlyParts List/Tune Up InfoPDF 186.8 KB

Application Information

Application IDg8yqF2VAAPI3CROMK3nEIg==
Final Action Date2006-06-14
Application PurposeOriginal Equipment
Applicant FRN0007053853
Model0602DBS01
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Phone
Responsible PartyJames Wen, Manager, jameswen@fihtdc.com , 886222685511
Technical ContactDaniel Lee, Sporton International, daniel@sporton.com.tw , +886 3 327 3456
Non-Technical ContactCharlene Tsai, Chie Mei Communications Systems, Inc., charlenetsai@tp.cmcs.com.tw , +886 2 2370 8699
Test FirmKathy Lin, SPORTON International Inc, kathylin@sporton.com.tw , 886-2-2696-2468
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter except as indicated in this filing. Highest reported collocated SAR are Pt 15 head: 0.43 W/kg and body: 0.06 W/kg and collocated SAR are head: 1.54 W/kg and body: 1.42 W/kg.

Applications

Application IDDatePurpose
g8yqF2VAAPI3CROMK3nEIg==2006-06-14Original Equipment
TJfzRnYS18oT56djDrOxwQ==2006-06-14Original Equipment
P7ajhGyaihMJwAMuTXTxTQ==2006-06-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.060.02ppm300KGXW22HBC
1850.2-1909.8 MHz1.790.01ppm300KGXW24EBC
2402-2480 MHz0.001200015C
2412-2462 MHz0.026000015C

Grants

TCB Grant - Application TJfzRnYS18oT56djDrOxwQ==

This application does not exist.

EAS Grant - Application TJfzRnYS18oT56djDrOxwQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Chi Mei Communication Systems, Inc.
No. 4, MingSheng St. TuCheng City
Taipei County, 23678
Taiwan
  Date of Grant: 06/14/2006

Application Dated: 04/10/2006
 
Attention: James Wen , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QDJ-0602DBS01
Name of Grantee:  Chi Mei Communication Systems, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 1.79 0.01  PM 300KGXW
BC 22H 824.2  -  848.8 1.06 0.02  PM 300KGXW

SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter except as indicated in this filing. This device contains 900 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. Highest reported collocated SAR are Pt 22 head: 1.11 W/kg and body: 1.42 W/kg and Pt 24 head: 0.56 W/kg and body: 1.08 W/kg and collocated SAR are head: 1.54 W/kg and body: 1.42 W/kg.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

TCB Grant - Application P7ajhGyaihMJwAMuTXTxTQ==

This application does not exist.

EAS Grant - Application P7ajhGyaihMJwAMuTXTxTQ==

Mail To:
William Graff, President
AmericanTCB
6731 Whittier Ave.
McLean, VA 22101
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Chi Mei Communication Systems, Inc.
No. 4, MingSheng St. TuCheng City
Taipei County, 23678
Taiwan
  Date of Grant: 06/14/2006

Application Dated: 04/10/2006
 
Attention: James Wen , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QDJ-0602DBS01
Name of Grantee:  Chi Mei Communication Systems, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter except as indicated in this filing. This device contains 900 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. Highest reported collocated SAR are Pt 22 head: 1.11 W/kg and body: 1.42 W/kg and Pt 24 head: 0.56 W/kg and body: 1.08 W/kg and collocated SAR are head: 1.54 W/kg and body: 1.42 W/kg.



TCB Grant - Application g8yqF2VAAPI3CROMK3nEIg==

This application does not exist.

EAS Grant - Application g8yqF2VAAPI3CROMK3nEIg==

Mail To:
William Graff, President
AmericanTCB
6731 Whittier Avenue
McLean, VA 22101
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Chi Mei Communication Systems, Inc.
No. 4, MingSheng St. TuCheng City
Taipei County, 23678
Taiwan
  Date of Grant: 06/14/2006

Application Dated: 04/10/2006
 
Attention: James Wen , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QDJ-0602DBS01
Name of Grantee:  Chi Mei Communication Systems, Inc.
Equipment Class: Digital Transmission System
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.026  

SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter except as indicated in this filing. Highest reported collocated SAR are Pt 15 head: 0.43 W/kg and body: 0.06 W/kg and collocated SAR are head: 1.54 W/kg and body: 1.42 W/kg.



Mail To:
William Graff, President
AmericanTCB
6731 Whittier Avenue
McLean, VA 22101