FCC ID QFS001-10037200L
Ground radar
by Dynetics, Inc.
Grantee Code: QFS Product Code: 00110037200L
Latest application date: 2019-08-30
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 3023.4-3070.3 MHz | Original Equipment | 2019-08-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| GroundAwareManual1360LRevB | Users Manual | 2019-08-30 | PDF 262.5 KB |
| ExternalPhotos | External Photos | 2019-08-30 | PDF 542.4 KB |
| FCC Label | ID Label/Location Info | 2019-08-30 | PDF 260.3 KB |
| R12902541-E1 v3 FCC Part 90 Setup photos | Test Setup Photos | 2019-08-30 | PDF 1.3 MB |
| R12902541-E1 v3 FCC Part 90 REPORT only | Test Report | 2019-08-30 | PDF 3.3 MB |
| 14_Request for Confidentiality (1) | Cover Letter(s) | 2019-08-30 | PDF 79.4 KB |
| Agency Authorization | Cover Letter(s) | 2019-08-30 | PDF 145.6 KB |
| Confidentiality Steps Exhibit | Cover Letter(s) | 2019-08-30 | PDF 359.4 KB |
| ExampleNDA | Cover Letter(s) | 2019-08-30 | PDF 2.2 MB |
| R12902541-E2 v3 FCC IC MPE REPORT | RF Exposure Info | 2019-08-30 | PDF 333.6 KB |
| InternalPhotos Metadata only | Internal Photos | PDF 1.3 MB | |
| BlockDiagram Metadata only | Block Diagram | PDF 125.9 KB | |
| [Confidential]SchematicDiagram Metadata only | Schematics | PDF 410.2 KB | |
| AntennaSpecification Metadata only | Operational Description | PDF 96.4 KB | |
| FCC Inquiry on Part 90 Results Metadata only | Operational Description | PDF 109.3 KB | |
| [Confidential]TheoryOfOperationRevB Metadata only | Parts List/Tune Up Info | PDF 108.2 KB |
Application Information
| Application ID | xa9Qdy0PcnLI6lWBdp/SaA== |
|---|---|
| Final Action Date | 2019-08-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0007244478 |
| Model | 001-10037200L |
| Frequency Range | 3023.4-3070.3 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Ground radar |
| Responsible Party | Paul E Byrge, Contracts Deputy, paul.byrge@dynetics.com |
| Test Firm | Rick Titus, UL LLC, rick.a.titus@ul.com |
| TCB Email | LST.FRE.CertNotice@ul.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output power is conducted. The antenna used with this transmitter has a maximum gain of 3 dBi and must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Installers and end users must be provided with specific operating instructions and antenna installation requirements for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xa9Qdy0PcnLI6lWBdp/SaA== | 2019-08-30 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application xa9Qdy0PcnLI6lWBdp/SaA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 08/30/2019 Application Dated: 08/29/2019 |
| Dynetics, Inc. |
| 1002 Explorer Blvd. |
| Huntsville, AL 35806 |
| Attention: Paul Byrge , Contracts Deputy |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QFS001-10037200L |
| Name of Grantee: | Dynetics, Inc. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Ground radar |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 3023.4 - 3070.3 | 0.479 | 106.01 PM | 32M2Q3N |
| Output power is conducted. The antenna used with this transmitter has a maximum gain of 3 dBi and must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Installers and end users must be provided with specific operating instructions and antenna installation requirements for satisfying RF exposure compliance. |
EAS Grant - Application xa9Qdy0PcnLI6lWBdp/SaA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Dynetics, Inc. 1002 Explorer Blvd. Huntsville, AL 35806 United States |
Date of Grant: 08/30/2019 Application Dated: 08/29/2019 |
| Attention: Paul Byrge , Contracts Deputy |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QFS001-10037200L |
| Name of Grantee: | Dynetics, Inc. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Ground radar |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 3023.4 - 3070.3 | 0.479 | 106.01 PM | 32M2Q3N |
| Output power is conducted. The antenna used with this transmitter has a maximum gain of 3 dBi and must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Installers and end users must be provided with specific operating instructions and antenna installation requirements for satisfying RF exposure compliance. |
| Mail To: |