| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.7-848.31 MHz | Class II permissive change or modification of presently authorized equipment | 2013-11-20 |
| 2405-2475 MHz | Original Equipment | 2011-01-12 |
| 824.7-848.31 MHz | Original Equipment | 2011-01-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-07-11 | PDF 187.3 KB |
| Internal Photos | Internal Photos | 2011-07-11 | PDF 4.8 MB |
| External Photos | External Photos | 2011-07-11 | PDF 1.3 MB |
| FCC ID Label and Location | ID Label/Location Info | 2011-01-12 | PDF 1.8 MB |
| Test Setup Photos | Test Setup Photos | 2013-11-20 | PDF 517.2 KB |
| Test Setup Photos | Test Setup Photos | 2011-07-11 | PDF 607.2 KB |
| Test Report | Test Report | 2013-11-20 | PDF 629.7 KB |
| Test Report | Test Report | 2011-01-12 | PDF 1.7 MB |
| Test Report | Test Report | 2011-01-12 | PDF 1.3 MB |
| Attestation Statement | Attestation Statements | 2011-01-12 | PDF 269.4 KB |
| Class II Cover Letter | Cover Letter(s) | 2013-11-20 | PDF 2.7 MB |
| Confidentiality Request Letter | Cover Letter(s) | 2011-01-12 | PDF 431.7 KB |
| MPE Report | RF Exposure Info | 2011-01-12 | PDF 195.4 KB |
Application Information
| Application ID | KDvbCtLFzDyKj8+ae6OM9Q== |
|---|---|
| Final Action Date | 2013-11-20 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0015586100 |
| Model | -OPENWAY1X |
| Frequency Range | 824.7-848.31 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Responsible Party | Mike Mathis, Senior Compliance Engineer, mike.mathis@itron.com |
| Technical Contact | Randy Ortanez, PCTEST Engineering Lab., Inc., tcb@pctestlab.com |
| Test Firm | Randy Ortanez, PCTEST Engineering Laboratory, Inc., lab@pctestlab.com |
| TCB Email | tcb@pctestlab.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change. Power output listed is ERP for Part 22 and EIRP for Part 24. This device is approved as a mobile device with respect to RF exposure compliance. The antenna used with this transmitter must be installed to provide a minimum separation distance of 20 cm from all persons, and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing and/or in accordance with FCC multi-transmitter product guidelines. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| KDvbCtLFzDyKj8+ae6OM9Q== | 2013-11-20 | Class II permissive change or modification of presently authorized equipment |
| qyQShueZQG40Zcuk5aK8uQ== | 2011-01-12 | Original Equipment |
| U4fbtNyryqekVmRMaG7Txw== | 2011-01-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application U4fbtNyryqekVmRMaG7Txw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road Columbia, MD 21045 |
Date of Grant: 01/12/2011 Application Dated: 01/12/2011 |
| Itron |
| 4400 Old Canton Road |
| Suite 300 |
| Jackson, MS 39211 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.072 | 2.5 PM | 1M27F9W | |
| 24E | 1851.25 - 1908.75 | 0.366 | 2.5 PM | 1M27F9W |
| Power output listed is ERP for Part 22 and EIRP for Part 24. This device is approved as a mobile device with respect to RF exposure compliance. The antenna used with this transmitter must be installed to provide a minimum separation distance of 20 cm from all persons, and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing and/or in accordance with FCC multi-transmitter product guidelines. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application U4fbtNyryqekVmRMaG7Txw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron 4400 Old Canton Road Suite 300 Jackson, MS 39211 United States |
Date of Grant: 01/12/2011 Application Dated: 01/12/2011 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.072 | 2.5 PM | 1M27F9W | |
| 24E | 1851.25 - 1908.75 | 0.366 | 2.5 PM | 1M27F9W |
| Power output listed is ERP for Part 22 and EIRP for Part 24. This device is approved as a mobile device with respect to RF exposure compliance. The antenna used with this transmitter must be installed to provide a minimum separation distance of 20 cm from all persons, and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing and/or in accordance with FCC multi-transmitter product guidelines. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road Columbia, MD 21045 |
Date of Grant: 01/12/2011 Application Dated: 01/12/2011 |
| Itron |
| 4400 Old Canton Road |
| Suite 300 |
| Jackson, MS 39211 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | Digital Transmission System |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2475.0 | 0.032 |
| Output power is conducted. This device is approved for use in the transceiver described in the filing. |
EAS Grant - Application qyQShueZQG40Zcuk5aK8uQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron 4400 Old Canton Road Suite 300 Jackson, MS 39211 United States |
Date of Grant: 01/12/2011 Application Dated: 01/12/2011 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | Digital Transmission System |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2475.0 | 0.032 |
| Output power is conducted. This device is approved for use in the transceiver described in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road Columbia, MD 21045 |
Date of Grant: 11/20/2013 Application Dated: 11/20/2013 |
| Itron |
| 4400 Old Canton Road |
| Suite 300 |
| Jackson, MS 39211 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.072 | 2.5 PM | 1M27F9W | |
| 24E | 1851.25 - 1908.75 | 0.366 | 2.5 PM | 1M27F9W |
| Class II Permissive Change. Power output listed is ERP for Part 22 and EIRP for Part 24. This device is approved as a mobile device with respect to RF exposure compliance. The antenna used with this transmitter must be installed to provide a minimum separation distance of 20 cm from all persons, and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing and/or in accordance with FCC multi-transmitter product guidelines. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application KDvbCtLFzDyKj8+ae6OM9Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron 4400 Old Canton Road Suite 300 Jackson, MS 39211 United States |
Date of Grant: 11/20/2013 Application Dated: 11/20/2013 |
| Attention: Mike Mathis , Senior Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QHC-OPENWAY1X |
| Name of Grantee: | Itron |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/ PCS CDMA Power Meter with Zigbee Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.072 | 2.5 PM | 1M27F9W | |
| 24E | 1851.25 - 1908.75 | 0.366 | 2.5 PM | 1M27F9W |
| Class II Permissive Change. Power output listed is ERP for Part 22 and EIRP for Part 24. This device is approved as a mobile device with respect to RF exposure compliance. The antenna used with this transmitter must be installed to provide a minimum separation distance of 20 cm from all persons, and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing and/or in accordance with FCC multi-transmitter product guidelines. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |