Test FirmDEKRA TESTING AND CERTIFICATION CO., LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2023-12-26
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2023-12-26
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2023-12-26
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2023-12-23
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2023-12-23
5745-5825 MHzClass II permissive change or modification of presently authorized equipment2023-12-23
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2023-12-05
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2023-12-05
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2023-12-05
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/20212023-10-30
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/20212023-10-30
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/20212023-10-30

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2023-12-26PDF 890.5 KB
Users ManualUsers Manual2023-12-26PDF 890.5 KB
Users ManualUsers Manual2023-12-23PDF 493.6 KB
Users ManualUsers Manual2023-12-05PDF 434 KB
Users ManualUsers Manual2023-10-30PDF 515.5 KB
Internal PhotosInternal Photos2023-12-26PDF 2.7 MB
Internal Photos-1Internal Photos2023-12-23PDF 5.1 MB
Internal Photos-2Internal Photos2023-12-23PDF 4.7 MB
Internal PhotosInternal Photos2023-12-05PDF 2.3 MB
External PhotosExternal Photos2023-12-26PDF 3.1 MB
External PhotosExternal Photos2023-12-23PDF 1.6 MB
External PhotosExternal Photos2023-12-05PDF 1.9 MB
External PhotosExternal Photos2023-10-30PDF 103.9 KB
ID LabelID Label/Location Info2023-12-26PDF 91.1 KB
Label LocationID Label/Location Info2023-12-26PDF 225.3 KB
ID LabelID Label/Location Info2023-12-23PDF 229 KB
Label LocationID Label/Location Info2023-12-23PDF 999.3 KB
ID LabelID Label/Location Info2023-12-05PDF 55.4 KB
ID Label/Location InfoID Label/Location Info2023-12-05PDF 735.4 KB
Label LocationID Label/Location Info2023-12-05PDF 735.4 KB
ID Label/Location InfoID Label/Location Info2023-10-30PDF 209.8 KB
DTS Test Setup Photos_BLETest Setup Photos2023-12-26PDF 1.8 MB
DTS Test Setup Photos_Wifi2.4GTest Setup Photos2023-12-26PDF 1.8 MB
Test Setup Photos_DSSTest Setup Photos2023-12-26PDF 1.8 MB
Test Setup Photos_NIITest Setup Photos2023-12-26PDF 1.8 MB
Test Setup PhotosTest Setup Photos2023-12-23PDF 1.3 MB
Test Setup PhotosTest Setup Photos2023-12-23PDF 1.3 MB
Test Setup Photos_BLETest Setup Photos2023-12-23PDF 1.3 MB
Test Setup Photos_WLANTest Setup Photos2023-12-23PDF 1.3 MB
Test Setup Photos_BLETest Setup Photos2023-12-05PDF 1.9 MB
Test Setup Photos_DSSTest Setup Photos2023-12-05PDF 1.9 MB
Test Setup Photos_NIITest Setup Photos2023-12-05PDF 1.9 MB
Test Setup Photos_SARTest Setup Photos2023-12-05PDF 518.9 KB
Test Setup Photos_WLANTest Setup Photos2023-12-05PDF 1.9 MB
Antenna Spec.Test Report2023-12-26PDF 661.4 KB
DTS test report_BT LETest Report2023-12-26PDF 1.3 MB
DTS test report_Wifi2.4GTest Report2023-12-26PDF 2 MB
Test Report_DSSTest Report2023-12-26PDF 1.2 MB
Test Report_NIITest Report2023-12-26PDF 1.1 MB
Antenna Spec._603ANT0102X00-01Test Report2023-12-23PDF 2.7 MB
Antenna Spec._603ANT0104X00-01Test Report2023-12-23PDF 4.4 MB
Test ReportTest Report2023-12-23PDF 4.7 MB
Test ReportTest Report2023-12-23PDF 1.5 MB
Test Report_BLETest Report2023-12-23PDF 1.6 MB
Test Report_WLANTest Report2023-12-23PDF 2.3 MB
Antenna Spec._SIMPAD-603ANT0101X00-01Test Report2023-12-05PDF 5.8 MB
Antenna Spec._SIMPAD-603ANT0119X00-01Test Report2023-12-05PDF 3 MB
Test ReportTest Report2023-12-05PDF 726.7 KB
Test Report_BLETest Report2023-12-05PDF 698.4 KB
Test Report_NIITest Report2023-12-05PDF 767.8 KB
Test Report_SARRF Exposure Info2023-12-05PDF 1.1 MB
Test Report_WLANTest Report2023-12-05PDF 703.7 KB
Covered list Attestation Statement_Part 2.911_d__5__i_Attestation Statements2023-12-26PDF 319.9 KB
Covered list Attestation Statement_Part 2.911_d__5__ii_Attestation Statements2023-12-26PDF 371 KB
US AgentAttestation Statements2023-12-26PDF 325 KB
Attestation Statement_Part 2.911_d__5__iAttestation Statements2023-12-23PDF 319.9 KB
Attestation Statement_Part 2.911_d__5__iiAttestation Statements2023-12-23PDF 371 KB
US agentAttestation Statements2023-12-23PDF 325 KB
U.S. Agent Authorized LetterAttestation Statements2023-12-05PDF 325 KB
U.S. Agent LetterAttestation Statements2023-12-05PDF 325 KB
Authorization LetterCover Letter(s)2023-12-26PDF 193.9 KB
Confidential Request LetterCover Letter(s)2023-12-26PDF 946 KB
Permissive Change Request LetterCover Letter(s)2023-12-26PDF 208.8 KB
ConfidentialityCover Letter(s)2023-12-23PDF 946 KB
Permissive Change Request Letter Metadata onlyCover Letter(s)2023-12-23PDF 209.8 KB
Permissive Change Request Letter_revised 1219Cover Letter(s)2023-12-23PDF 781.4 KB
Authorisation letterCover Letter(s)2023-12-05PDF 193.9 KB
Permissive Change Request LetterCover Letter(s)2023-12-05PDF 210.1 KB
Authorization letterCover Letter(s)2023-10-30PDF 193.9 KB
Change in ID_Authorization Original GranteeCover Letter(s)2023-10-30PDF 95.8 KB
Change in ID_New GranteeCover Letter(s)2023-10-30PDF 328.3 KB
MPE ReportRF Exposure Info2023-12-26PDF 218.1 KB
RF Exposure InfoRF Exposure Info2023-12-23PDF 221 KB
Appendix A. System Check DataRF Exposure Info2023-12-05PDF 186.7 KB
Appendix B. Highest Measurement Data-Plot No.RF Exposure Info2023-12-05PDF 224.6 KB
Appendix D. Probe CalibrationRF Exposure Info2023-12-05PDF 1.5 MB
Appendix E. Dipole _ Source CalibrationRF Exposure Info2023-12-05PDF 3.2 MB
Block Diagram Metadata onlyBlock DiagramPDF 142.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 213.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 181.8 KB
Schematics Metadata onlySchematicsPDF 923.3 KB
Schematics Metadata onlySchematicsPDF 1.3 MB
Schematics Metadata onlySchematicsPDF 673.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 1,023.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 1.1 MB
Operational Description Metadata onlyOperational DescriptionPDF 535.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 357.5 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 216.6 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 170.5 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 362.5 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 361.9 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 362.9 KB
Tune-up Procedure Metadata onlyParts List/Tune Up InfoPDF 362.9 KB

Application Information

Application IDqWmxkKb5yYUyCZDAIHd+Pg==
Final Action Date2023-12-26
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0007349657
ModelLB1YM
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionCommunication Module
Responsible PartyMari Kaada, Corporate Regulatory Affairs Manager, mari.kaada@laerdal.no , +4751511700
AgentPhoenix Phoenix Phoenix, DEKRA Testing and Certification Co., Ltd., phoenix.chen@dekra.com , 886-3-275-7255
Technical ContactPhoenix Chen, DEKRA Testing and Certification Co., Lt, phoenix.chen@dekra.com , 886-3-275-7255
Non-Technical ContactVera Hsu, DEKRA Testing and Certification Co., Lt, vera.hsu@dekra.com , 886-3-275-7255
Test FirmWarren Lin, DEKRA TESTING AND CERTIFICATION CO., LTD., warren.lin@dekra.com , +886-3-582-8001
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz bandwidth mode.

Applications

Application IDDatePurpose
qWmxkKb5yYUyCZDAIHd+Pg==2023-12-26Class II permissive change or modification of presently authorized equipment
gYOgOWrcjfh22PTOAhqLTQ==2023-12-26Class II permissive change or modification of presently authorized equipment
WSF6HTXyWr3BNYhZy177Fw==2023-12-26Class II permissive change or modification of presently authorized equipment
vIXV1OnpLu8hmD/KiyCmcw==2023-12-23Class II permissive change or modification of presently authorized equipment
GpE3H1GIIpqhZ3Wg5rsuYA==2023-12-23Class II permissive change or modification of presently authorized equipment
/6huLSnFR5/p53/eVVLwww==2023-12-23Class II permissive change or modification of presently authorized equipment
rbKJFUSP6sNzZ0l6NR8efg==2023-12-05Class II permissive change or modification of presently authorized equipment
jKjNTtlxCkaevNNBsJ7Uig==2023-12-05Class II permissive change or modification of presently authorized equipment
3UTNXjBafm6ksjG9gVEh+g==2023-12-05Class II permissive change or modification of presently authorized equipment
e7v5Rz3YIotX6cmGec2wKw==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/2021
77A6MiXBsZV0JgTevEnvGA==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/2021
2UrNFw7m7MN6I6c8swmqpg==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: VPYLB1YM Grant Date: 01/19/2021

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.00415CCC
2402-2480 MHz0.004000015CCC
2412-2462 MHz0.6515CCC, MO
5180-5240 MHz0.03115ECC, MO
5260-5320 MHz0.07915ECC, MO, ND
5500-5700 MHz0.07815ECC, MO, ND
5745-5825 MHz0.115ECC, MO

Grants

TCB Grant - Application WSF6HTXyWr3BNYhZy177Fw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/26/2023

Application Dated: 12/25/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application WSF6HTXyWr3BNYhZy177Fw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/26/2023

Application Dated: 12/25/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application vIXV1OnpLu8hmD/KiyCmcw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/23/2023

Application Dated: 12/18/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application vIXV1OnpLu8hmD/KiyCmcw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/23/2023

Application Dated: 12/18/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application rbKJFUSP6sNzZ0l6NR8efg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/05/2023

Application Dated: 12/05/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.08 W/kg and 1.08 W/kg, respectively.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application rbKJFUSP6sNzZ0l6NR8efg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/05/2023

Application Dated: 12/05/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.08 W/kg and 1.08 W/kg, respectively.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application qWmxkKb5yYUyCZDAIHd+Pg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/26/2023

Application Dated: 12/25/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application qWmxkKb5yYUyCZDAIHd+Pg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/26/2023

Application Dated: 12/25/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application jKjNTtlxCkaevNNBsJ7Uig==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/05/2023

Application Dated: 12/05/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.00 W/kg and 1.01 W/kg, respectively.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application jKjNTtlxCkaevNNBsJ7Uig==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/05/2023

Application Dated: 12/05/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.00 W/kg and 1.01 W/kg, respectively.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application gYOgOWrcjfh22PTOAhqLTQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/26/2023

Application Dated: 12/25/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application gYOgOWrcjfh22PTOAhqLTQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/26/2023

Application Dated: 12/25/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: CAN CPU Module 2, Brand: Laerdal Medical AS, Model: 20-19560). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application GpE3H1GIIpqhZ3Wg5rsuYA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/23/2023

Application Dated: 12/18/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application GpE3H1GIIpqhZ3Wg5rsuYA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/23/2023

Application Dated: 12/18/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application e7v5Rz3YIotX6cmGec2wKw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application e7v5Rz3YIotX6cmGec2wKw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application 77A6MiXBsZV0JgTevEnvGA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 77A6MiXBsZV0JgTevEnvGA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Digital Transmission System
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  
CC MO 15C 2412.0  -  2462.0 0.65  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has a 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 3UTNXjBafm6ksjG9gVEh+g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/05/2023

Application Dated: 12/05/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are <0.01 W/kg and 1.08 W/kg, respectively. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 3UTNXjBafm6ksjG9gVEh+g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/05/2023

Application Dated: 12/05/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Class II Permissive Change. This change is : (a) Additional platform added (Product: SimPad PLUS 2, Brand: Laerdal Medical AS, Model: 204-00150). (b) Add Dipole antennas with lower gain. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are <0.01 W/kg and 1.08 W/kg, respectively. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 2UrNFw7m7MN6I6c8swmqpg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2UrNFw7m7MN6I6c8swmqpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.004  

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application /6huLSnFR5/p53/eVVLwww==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/23/2023

Application Dated: 12/18/2023
Laerdal Medical AS
Tanke Svilandsgate 30
P.O. Box 377,
Stavanger, 4002
Norway
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application /6huLSnFR5/p53/eVVLwww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Laerdal Medical AS
Tanke Svilandsgate 30 P.O. Box 377,
Stavanger, 4002
Norway
  Date of Grant: 12/23/2023

Application Dated: 12/18/2023
 
Attention: Mari Kaada , Corporate Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QHQ-LB1YM
Name of Grantee:  Laerdal Medical AS
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Communication Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.031  
CC MO ND 15E 5260.0  -  5320.0 0.079  
CC MO ND 15E 5500.0  -  5700.0 0.078  
CC MO 15E 5745.0  -  5825.0 0.1  

Class II Permissive Change. This change is : (a) Additional platform added (Product: Link Box PLUS 2, Brand: Laerdal Medical AS, Model: 204-00250). (b) Add Dipole antennas with higher gain.

Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz, 5690 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

Mail To: