FCC ID QISCBTS3612-800
CDMA Base Station
by Huawei Technologies Co.,Ltd
Grantee Code: QIS Product Code: CBTS3612800
Latest application date: 2002-09-13
FCC ID Device Details
| FCC ID | QISCBTS3612-800 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | QIS |
| Product Code | CBTS3612800 |
| Applicant Business | Huawei Technologies Co.,Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | CDMA Base Station |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 869-894 MHz | Original Equipment | 2002-09-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Maintenance Manual | Users Manual | 2002-09-13 | PDF 302.1 KB |
| User Manual | Users Manual | 2002-09-13 | PDF 1.2 MB |
| Internal Photos | Internal Photos | 2002-09-13 | PDF 2.9 MB |
| External 1 | External Photos | 2002-09-13 | PDF 566.3 KB |
| Label Metadata only | ID Label/Location Info | 2002-09-13 | PDF 901.5 KB |
| Label Artwork | ID Label/Location Info | 2002-09-13 | PDF 901.5 KB |
| Label Location | ID Label/Location Info | 2002-09-13 | PDF 193.2 KB |
| Appendix A Power Output | Test Report | 2002-09-13 | PDF 48.3 KB |
| Appendix B Modulation | Test Report | 2002-09-13 | PDF 48.1 KB |
| Appendix C OBW | Test Report | 2002-09-13 | PDF 54.1 KB |
| Appendix D Conducted Spurious | Test Report | 2002-09-13 | PDF 154.7 KB |
| Appendix E Field Strength Spurious | Test Report | 2002-09-13 | PDF 237.9 KB |
| Appendix F Frequency Stability | Test Report | 2002-09-13 | PDF 2.1 MB |
| Appendix G Conducted | Test Report | 2002-09-13 | PDF 54 KB |
| Signature Page | Test Report | 2002-09-13 | PDF 44.8 KB |
| Test Report | Test Report | 2002-09-13 | PDF 250.8 KB |
| Confidentiality Request | Cover Letter(s) | 2002-09-13 | PDF 115.6 KB |
| Confidentiality Request email reply | Cover Letter(s) | 2002-09-13 | PDF 6.2 KB |
| BTS Metadata only | Block Diagram | PDF 19.5 KB | |
| CDU Metadata only | Block Diagram | PDF 42.6 KB | |
| RF Metadata only | Block Diagram | PDF 58 KB | |
| Schematic 1 Metadata only | Schematics | PDF 1.8 MB | |
| Schematic 2 Metadata only | Schematics | PDF 1.5 MB | |
| Schematic 3 Metadata only | Schematics | PDF 1.7 MB | |
| Schematic 4 Metadata only | Schematics | PDF 812.5 KB | |
| Schematic 5 Metadata only | Schematics | PDF 463.5 KB | |
| Schematic 6 Metadata only | Schematics | PDF 1.5 MB | |
| Operation Description Metadata only | Operational Description | PDF 305.1 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 161.4 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 54 KB |
Application Information
| Application ID | W10FbCglme+788u+BAbuHQ== |
|---|---|
| Final Action Date | 2002-09-13 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0007419963 |
| Model | CBTS3612-800 |
| Frequency Range | 869-894 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | CDMA Base Station |
| Responsible Party | Zhang Xinghai, zhangxinghai@huawei.com |
| Agent | Wang Wang Wang, TUV Rheinland (Shenzhen) Co. Ltd., wwei@sz.chn.tuv.com |
| Technical Contact | Wang Wei, TUV Rheinland (Shenzhen) Co., Ltd., wwei@sz.chn.tuv.com |
| Non-Technical Contact | Wang Wei, TUV Rheinland (Shenzhen) Co., Ltd., wwei@sz.chn.tuv.com |
| TCB Email | tdwyer@us.tuv.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is conducted at antenna terminal. Equipment qualifies for both Non-building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| W10FbCglme+788u+BAbuHQ== | 2002-09-13 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application W10FbCglme+788u+BAbuHQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV Rheinland of North America, Inc. 1279 Quarry Lane Suite A Pleasanton, CA 94566 |
Date of Grant: 09/13/2002 Application Dated: 09/13/2002 |
| Huawei Technologies Co.,Ltd |
| Administration Building, Headquarters of Huawei |
| Technologies Co., Ltd., Bantian, Longgang District |
| Shenzhen, China |
| Attention: Zhang Xinghai |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QISCBTS3612-800 |
| Name of Grantee: | Huawei Technologies Co.,Ltd |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | CDMA Base Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22.901(d) | 869.0 - 894.0 | 20.0 | 0.05 PM | 1M25F9W |
| Power output is conducted at antenna terminal. Equipment qualifies for both Non-building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
EAS Grant - Application W10FbCglme+788u+BAbuHQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Huawei Technologies Co.,Ltd Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District Shenzhen, China |
Date of Grant: 09/13/2002 Application Dated: 09/13/2002 |
| Attention: Zhang Xinghai |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QISCBTS3612-800 |
| Name of Grantee: | Huawei Technologies Co.,Ltd |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | CDMA Base Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22.901(d) | 869.0 - 894.0 | 20.0 | 0.05 PM | 1M25F9W |
| Power output is conducted at antenna terminal. Equipment qualifies for both Non-building-mounted and Building-mounted antenna categories as defined in 1.1307. For Non-building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). For Building-mounted antennas: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 800 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| Mail To: |