TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd

Huawei Technologies Co.,Ltd Smart Band

Page 1 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 2 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 3 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 4 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 5 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 6 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 7 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 8 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 9 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 10 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 11 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 12 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 13 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 14 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 15 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 16 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Page 17 of TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd

EMC Test Report
Product Name:
Smart Band
Product Model:
TER-B09
Report Number:
SYBH(Z-EMC) 20181229013001-2
FCC ID:QISTER-B09
IC ID:6369A-TERB09
Reliability Laboratory of Huawei Technologies Co., Ltd.
(Global Compliance and Testing Center of Huawei Technologies Co., Ltd)
No.2 No.2, New City Avenue, Songshan Lake Sci. & Tech. Industry Park, Dongguan, 523808, P.R.C
Tel: +86 769 23830808
Report No.: SYBH(Z-EMC)
20190121012001-2
Fax: +86 769 23837628
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co.,
Ltd
Page 1 of 17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Notice
1. The laboratory has passed the accreditation by China National Accreditation Service for
Conformity Assessment (CNAS). The accreditation number is L0310.
2. The laboratory has passed the accreditation by The American Association for Laboratory
Accreditation (A2LA). The accreditation number is 2174.01
3. The laboratory has been recognized by the Innovation, Science and Economic Development
Canada (ISED) to test to Canadian radio equipment requirements. The CAB identifier is
CN0003, and the ISED# is 21741.
4. The laboratory (Reliability Lab of Huawei Technologies Co., Ltd.) is also named “Global
Compliance and Testing Center of Huawei Technologies Co., Ltd.”, the both names have
coexisted since 2009.
5. The laboratory has been recognized by the US Federal Communications Commission (FCC)
to perform compliance testing subject to the Commission's Certification rules. The
Designation Number is CN1173, and the Test Firm Registration Number is 294140.
6. The test report is invalid if not marked with the signatures of the persons responsible for
preparing and approving the test report.
7. The test report is invalid if there is any evidence of erasure and/or falsification.
8. If there is any dissidence for the test report, please file objection to the test centre within 15
days from the date of receiving the test report.
9. Normally, the test report is only responsible for the samples that have undergone the test.
10. Content of the test report, in part or in full, cannot be used for publicity and/or promotional
purposes without prior written approval from the laboratory.
11. If any question about this report, please contact the laboratory (PublicGCTC@huawei.com).
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page2, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Applicant:
Huawei Technologies Co., Ltd.
Address:
No.2 New City Avenue Songshan Lake Sci. &Tech.
Industry Park, Dongguan, Guangdong, P.R.C
Date of Receipt Test Item:
2019-1-30
Start Date of Test:
2019-2-11
End Date of Test:
2019-2-15
Test Result:
Pass
Approved By
(Lab Manager)
2019-2-18
Date
Operator
(Test Engineer)
2018-2-15
Date
Report No: SYBH(Z-EMC)
20181229013001-2
Roger Zhang
Name
Hu haizhou
Name
Confidential Information of Huawei.
No Distribution without Written Permission
Signature
Signature
Page3, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Modification Record
No.
Last Report Version
Modification Description
V1.0
First report
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page4, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
TABLE OF CONTENT
1.1
1.2
1.3
General Information ............................................................................................................................ 6
EUT Description ......................................................................................................................... 6
Test Site Information ................................................................................................................... 7
Applied Standards ...................................................................................................................... 7
Summary of Results ........................................................................................................................... 8
3.1
3.2
3.3
System Configuration during EMC Test ............................................................................................ 9
Test Mode ................................................................................................................................... 9
Test System Configuration ....................................................................................................... 10
Associated Equipment Used during Test ................................................................................ 10
4.1
4.2
Electromagnetic Interference (EMI) ................................................................................................. 11
Radiated Disturbance 30MHz to 18GHz .................................................................................. 11
Conducted Disturbance 0.15 MHz to 30MHz ........................................................................... 13
Main Test Instruments ...................................................................................................................... 14
System Measurement Uncertainty ................................................................................................... 14
7.1
7.2
Test Data and Graph ........................................................................................................................ 15
Radiated Disturbance ............................................................................................................... 15
Conducted Disturbance ............................................................................................................ 17
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page5, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
1.1
Security Level: secret
General Information
EUT Description
EUT Description
Model Number
Smart Band
TER-B09
Input voltage
3.82V
TX Frequency
RX Frequency
HW Version
SW Version
Bluetooth: 2400MHz – 2483.5MHz
Bluetooth: 2400MHz – 2483.5MHz
EB1TERRAM04
1.0.0.11
Product Name
EUT Accessory
Charge dock
USB Cable
Li-polymer Battery
Manufacturer: Huawei Technologies Co.,Ltd.
Model: AF33-1
5V/1A
Manufacturer: Huawei Technologies Co.,Ltd.
5V1A,1m
Battery Model: HB351329ECW
Rated capacity: 100 mAh
Nominal Voltage:
+3.82V
Charging Voltage:
+4.40V
Discharging Voltage:
+3.00V
Manufacturer:
Tianjin lishen battery joint-stock.,LTD.
Remark: The above EUT’s information is declared by manufacturer. Please refer to the
specifications or user’s manual for more detailed information.
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page6, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
1.2
1.3
Security Level: secret
Test Site Information
Test Site 1:
RELIABILITY LABORATORY OF HUAWEI TECHNOLOGIES CO., LTD.
Test Site Location:
No.2 New City Avenue Songshan Lake Sci. &Tech. Industry Park,
Dongguan, Guangdong, P.R.C
Applied Standards
APPLIED STANDARD
47 CFR FCC Part 15, Subpart B
ICES-003 Issue 6
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page7, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Summary of Results
Summary of Results
Test Items
Test
Mode
Performance Class &
Required Performance
Criteria
Resul
Site
Radiated Emissions
Enclosure Port
Mode1
CLASS B
Pass
Site1
Mode1
CLASS B
Pass
Site1
Conducted Emissions
DC Power Port
AC Power Port
Telecommunication
Ports
Note:
1, Measurement taken is within the uncertainty of test system.
2,
The item has been tested;
The item has not been tested.
During the measurement, the environmental conditions complied with the range listed as below.
Item
Required
Ambient temperature
Relative humidity
Atmospheric pressure
15C~35C
25%~75%
86kPa~106kPa
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page8, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
System Configuration during EMC Test
3.1
Test Mode
The EUT was configured, installed, arranged and operated in a manner consistent with typical
application. The following mode(s) were applied during the compliance test.
Test Mode
Mode 1:
Charging + Normal operation + BT link
Remark:
1) If there is one kind of accessories with different models, each one should be applied
throughout the compliance test respectively, however, only the worst case will be recorded in
this report.
2) If EUT has more than one typical operation, only the worst test mode will be recorded in this
report.
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page9, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
3.2
Security Level: secret
Test System Configuration
Connection Diagram (Mode 1)
3.3
Associated Equipment Used during Test
Name
Mobile phone
Report No: SYBH(Z-EMC)
20181229013001-2
Model
Manufacturer
S/N
Honor 9
HuaWei
WMNDU17A27000145
Confidential Information of Huawei.
No Distribution without Written Permission
Calibrated
Deadline
Page10, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Electromagnetic Interference (EMI)
4.1 Radiated Disturbance 30MHz to 18GHz
4.1.1 Test Procedure
The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to the
standards: ANSI C63.4-2014. The test distance was 3m.The set-up and test methods were according to
ANSI C63.4-2014.
A preliminary scan and a final scan of the emissions were made from 30 MHz to18 GHz by using test
script of software; The emissions were measured using Quasi-Peak Detector (30MHz~1GHz) and
AV/PK detector (above 1GHz). The maximal emission value was acquired by adjusting the antenna
height, polarisation and turntable azimuth in accordance with the software setup. Normally, the height
range of antenna was 1m to 4m. The azimuth range of turntable was 0°to 360°. The receiving antenna
has two polarizations V and H.
Measurement bandwidth (RBW) for 30MHz to 1000 MHz: 120 kHz;
Measurement bandwidth (RBW) for 1000MHz to 18000 MHz: 1MHz;
EUT was configured in idle mode and the test performed at worst emission state.
4.1.2
Test setup
Figure 1. Test set-up of radiated disturbance(30MHz-1GHz )
Figure 2. Test set-up of radiated disturbance(above 1GHz)
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page11, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
4.1.3
Security Level: secret
Test Results
The EUT has met the requirements for Radiated Emission of enclosure port.
Refer to the section 7.1 of this report for test data.
Test Limits (Class B)
Frequency of Emission
(MHz)
Radiated Limit
Unit(μV/m)
Unit(dBμV/m)
30-88
100
40
88-216
150
43.5
216-960
Above 960
200
500
46
54
Above 1000
Report No: SYBH(Z-EMC)
20181229013001-2
AV
500
PK
5000
AV
54
Confidential Information of Huawei.
No Distribution without Written Permission
PK
74
Page12, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
4.2
Security Level: secret
Conducted Disturbance 0.15 MHz to 30MHz
4.2.1
Test Procedure
The Table-top EUT was placed upon a non-metallic table 0.8 m above the horizontal metal reference
ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT
was 80cm away from LISN. The set-up and test methods were according to ANSI C63.4-2014.
Conducted Disturbance at AC Port measurements were undertaken on the L and N Lines. The
emissions were measured using a Quasi-Peak Detector and Average Detector.
EUT was communicated with the simulator through Air interface, the simulator controls the EUT to
transmitter the maximum power which defined in specification of product. The EUT operated on the
typical channel.
Measurement bandwidth (RBW) for 150 kHz to 30 MHz: 9 kHz;
The EUT was set in the shielded chamber and operated under nominal conditions.
4.2.2
Test Setup
Figure 3. Test Set-up of conducted disturbance
4.2.3
Test Results
The EUT has met requirements for Conducted disturbance of power lines.
Refer to the section 7.2 of this report for test data.
Test Limit of AC Power Port
Frequency range
150kHz ~ 30MHz
Frequency
Voltage limits
QP (dBμV)
AV (dBμV)
0.15MHz~0.5MHz
0.5MHz-5MHz
5MHz~30MHz
66-56
56
60
56-46
46
50
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page13, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Main Test Instruments
Main Test Equipments
Test
item
Test
Instrument
EMI Test
receiver
Broadband
Antenna
RE
Horn Antenna
CE
EMI Test
receiver
Artificial Mains
Network
Model
S/N
Manufactur
er
Calibrated
Deadline
Cal
interval
ESU26
100150
R&S
Jun. 20, 2019
12
VULB 9163
9163-491
SCHWARZB
ECK
Mar. 28, 2019
24
HF906
100683
R&S
Mar. 28, 2019
24
ESU26
101163
R&S
Feb. 20, 2019
12
ENV216
100382
R&S
May. 15, 2019
12
Software Information
Test Item
Software Name
Manufacturer
Version
RE
EMC32
R&S
V9.25.0
CE
EMC32
R&S
V9.25.0
System Measurement Uncertainty
For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:
System Measurement Uncertainty
Items
RE(30MHz-1GHz)
RE(1GHz-18GHz)
CE
Report No: SYBH(Z-EMC)
20181229013001-2
Extended Uncertainty
Field strength (dBµV/m)
Field strength (dBµV/m)
Disturbance Voltage (dBμV)
U=5.52 dB; k=2
U=4.94 dB; k=2
U=2.3 dB; k=2
Confidential Information of Huawei.
No Distribution without Written Permission
Page14, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
Security Level: secret
Test Data and Graph
7.1
Radiated Disturbance
7.1.1
30MHz~1GHz
Test Mode1: Charging + Normal operation + BT link
MEASUREMENT RESULT: QP Detector
Frequency
Level
Transd
Limit
MHz
dBµV/m
dB
dBµV/m
39.764667
17.86
14.3
40.00
57.839000
18.86
13.7
40.00
82.994333
192.151667
214.849667
239.390667
17.19
18.24
19.20
21.28
10.7
12.1
12.7
13.8
40.00
43.50
43.50
46.00
Margin
dB
22.14
21.14
Height
cm
100.0
100.0
Azimuth
deg
79.0
29.0
22.81
25.26
24.30
24.72
100.0
100.0
100.0
100.0
161.0
19.0
358.0
10.0
Polarisation
Note:
Level =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
The reading level is calculated by software which is not shown in the sheet.
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page15, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
7.1.2
Security Level: secret
1GHz~18GHz
Test Mode1: Charging + Normal operation + BT link
Frequency in Hz
MEASUREMENT RESULT: PK Detector
Frequency
Level
Transd
Limit
MHz
dBµV/m
dB
dBµV/m
1986.000000
46.93
-9.3
74.0
4915.100000
46.11
-1.5
74.0
9894.966667
56.75
7.3
74.0
MEASUREMENT RESULT: AV Detector
Frequency
Level
Transd
Limit
MHz
dBµV/m
dB
dBµV/m
1994.500000
27.27
-9.2
54.0
4915.666667
39.25
-1.5
54.0
9895.533333
48.30
7.3
54.0
Margin
dB
27.07
27.89
Height
cm
100.0
Azimuth
deg
358.0
100.0
0.0
17.25
100.0
196.0
Polarisation
Margin
dB
26.73
14.75
Height
cm
100.0
100.0
Azimuth
deg
0.0
196.0
5.70
100.0
298.0
Polarisation
Note:
Level =Reading level by receiver + Transd (Antenna factor + cable loss – preamplifier gain)
The reading level is calculated by software which is not shown in the sheet.
Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page16, Total17
FCC&IC Test Report of TER-B09
FCC ID: QISTER-B09
IC ID: 6369A-TERB09
7.2
Security Level: secret
Conducted Disturbance
7.2.1
AC Port Test Data
Test Mode1: Charging + Normal operation + BT link
MEASUREMENT RESULT: QP Detector
Frequency
Level
Line
MHz
dBµV
0.156397
46.85
Transd
dB
9.7
Margin
dB
18.80
Limit
dBµV
65.65
PE
0.222003
0.285186
41.57
36.89
L1
9.7
9.7
21.17
23.77
62.74
60.66
FLO
FLO
FLO
0.379583
0.563326
31.02
21.94
9.7
9.8
27.27
34.06
58.29
56.00
FLO
FLO
2.334789
21.05
9.8
34.95
56.00
FLO
Transd
Margin
Limit
dB
9.7
9.7
dB
31.26
33.76
dBµV
55.90
55.00
FLO
FLO
MEASUREMENT RESULT: AV Detector
Frequency
Level
Line
MHz
dBµV
0.151913
24.64
L1
0.169179
21.24
L1
PE
0.223764
0.284713
19.32
18.43
L1
9.7
9.7
33.36
32.25
52.68
50.68
FLO
FLO
0.511601
2.327634
19.13
16.38
9.7
9.8
26.87
29.62
46.00
46.00
FLO
FLO
Note:
Level= Reading level+ Transd (cable loss + correction factor)
The reading level is calculated by software which is not shown in the sheet.
---------------------------------------------END---------------------------------------Report No: SYBH(Z-EMC)
20181229013001-2
Confidential Information of Huawei.
No Distribution without Written Permission
Page17, Total17
Download: TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Mirror Download [FCC.gov]TER-B09 Smart Band Test Report REPORT ON Huawei Technologies Co.,Ltd
Document ID4183892
Application IDs+hux7/XcApO6wCtnZyS7g==
Document DescriptionFCC Part15B test report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize48.72kB (609051 bits)
Date Submitted2019-02-27 00:00:00
Date Available2019-02-28 00:00:00
Creation Date2019-02-26 20:39:29
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2019-02-27 15:06:34
Document TitleREPORT ON
Document CreatorMicrosoft® Word 2013
Document Author: Lenovo User

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Lenovo User
Create Date                     : 2019:02:26 20:39:29+08:00
Modify Date                     : 2019:02:27 15:06:34+08:00
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c016 91.163616, 2018/10/29-16:58:49
Format                          : application/pdf
Creator                         : Lenovo User
Title                           : REPORT ON
Creator Tool                    : Microsoft® Word 2013
Metadata Date                   : 2019:02:27 15:06:34+08:00
Producer                        : Microsoft® Word 2013
Document ID                     : uuid:9d481a86-89cc-47f2-ad89-78a800e00f43
Instance ID                     : uuid:11b1c214-2e34-4285-aae2-86d30443cd72
Page Count                      : 17