FCC ID QL9-IPAD100-20

Mobile computer with Bluetooth and Wireless

by Fujitsu Transaction Solutions Inc.

Grantee Code: QL9   Product Code: IPAD10020
Latest application date: 2006-08-07

FCC ID Device Details

FCC IDQL9-IPAD100-20
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQL9
Product CodeIPAD10020
Applicant BusinessFujitsu Transaction Solutions Inc. 🇺🇸
Related Domains ftxs.fujitsu.com
Equipment ClassMobile computer with Bluetooth and Wireless
Test FirmRhein Tech Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2006-08-07
2412-2462 MHzOriginal Equipment2006-08-07

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2006-08-07PDF 125.9 KB
Internal photosInternal Photos2006-08-07PDF 2.3 MB
External photosExternal Photos2006-08-07PDF 562.4 KB
FCC ID labelID Label/Location Info2006-08-07PDF 507.4 KB
setup photosTest Setup Photos2006-08-07PDF 2.3 MB
Test reportTest Report2006-08-07PDF 2.6 MB
ATCB commentsCover Letter(s)2006-08-07PDF 49.2 KB
POACover Letter(s)2006-08-07PDF 82.1 KB
Request for ConfidentialityCover Letter(s)2006-08-07PDF 89.9 KB
Response to ATCBCover Letter(s)2006-08-07PDF 30.7 KB
SARRF Exposure Info2006-08-07PDF 2.5 MB
Block diagram Metadata onlyBlock DiagramPDF 306.3 KB
Schematics Metadata onlySchematicsPDF 1.8 MB
Operational description Metadata onlyOperational DescriptionPDF 3.9 MB

Application Information

Application IDa1uqsdxURCOO63N25JkUwQ==
Final Action Date2006-08-07
Application PurposeOriginal Equipment
Applicant FRN0007605132
ModelIPAD100-20
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMobile computer with Bluetooth and Wireless
Responsible PartyDwayne Andrejczuk, Regulatory Compliance Engineer, dandrejczuk@ftxs.fujitsu.com , 858-731-4719
Test FirmGalina Yushina, Rhein Tech Laboratories, Inc., gyushina@rheintech.com , 7036890368
TCB Emailhotline@AmericanTCB.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains a WLAN transmitter.

Applications

Application IDDatePurpose
a1uqsdxURCOO63N25JkUwQ==2006-08-07Original Equipment
QzamOaDJ60rdjomlXMlAwg==2006-08-07Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.002000015CCC
2412-2462 MHz0.089000015CCC

Grants

TCB Grant - Application QzamOaDJ60rdjomlXMlAwg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/07/2006

Application Dated: 08/07/2006
Fujitsu Transaction Solutions Inc.
10180 Barnes Canyon Road
San Diego, CA 92121
 
Attention: Dwayne Andrejczuk , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QL9-IPAD100-20
Name of Grantee:  Fujitsu Transaction Solutions Inc.
Equipment Class: Digital Transmission System
Notes: Mobile computer with Bluetooth and Wireless
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.089  

Power Output listed is Conducted. For body worn operation, this transmitter has been tested and meets the FCC RF exposure guidelines when used with the Fujitsu accessories designated for this product as shown in the filing. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter other than specified in the filing. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn 0.016 W/kg. This device contains a Bluetooth transmitter.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application QzamOaDJ60rdjomlXMlAwg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Fujitsu Transaction Solutions Inc.
10180 Barnes Canyon Road
San Diego, CA 92121
United States
  Date of Grant: 08/07/2006

Application Dated: 08/07/2006
 
Attention: Dwayne Andrejczuk , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QL9-IPAD100-20
Name of Grantee:  Fujitsu Transaction Solutions Inc.
Equipment Class: Digital Transmission System
Notes: Mobile computer with Bluetooth and Wireless
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.089  

Power Output listed is Conducted. For body worn operation, this transmitter has been tested and meets the FCC RF exposure guidelines when used with the Fujitsu accessories designated for this product as shown in the filing. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter other than specified in the filing. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn 0.016 W/kg. This device contains a Bluetooth transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application a1uqsdxURCOO63N25JkUwQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/07/2006

Application Dated: 08/07/2006
Fujitsu Transaction Solutions Inc.
10180 Barnes Canyon Road
San Diego, CA 92121
 
Attention: Dwayne Andrejczuk , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QL9-IPAD100-20
Name of Grantee:  Fujitsu Transaction Solutions Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile computer with Bluetooth and Wireless
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  

Power Output listed is Conducted. transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains a WLAN transmitter.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application a1uqsdxURCOO63N25JkUwQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Fujitsu Transaction Solutions Inc.
10180 Barnes Canyon Road
San Diego, CA 92121
United States
  Date of Grant: 08/07/2006

Application Dated: 08/07/2006
 
Attention: Dwayne Andrejczuk , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QL9-IPAD100-20
Name of Grantee:  Fujitsu Transaction Solutions Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile computer with Bluetooth and Wireless
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  

Power Output listed is Conducted. transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains a WLAN transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: