FCC ID QP8-MEI915WLAN
Remote Data Port
by Crane Payment Innovations
Grantee Code: QP8 Product Code: MEI915WLAN
Latest application date: 2003-09-30
FCC ID Device Details
| FCC ID | QP8-MEI915WLAN |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | QP8 |
| Product Code | MEI915WLAN |
| Applicant Business | Crane Payment Innovations 🇺🇸 |
| Related Domains | |
| Equipment Class | Remote Data Port |
| Test Firm | Washington Laboratories, Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 902.4-927.75 MHz | Original Equipment | 2003-09-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2003-09-30 | PDF 219.5 KB |
| Manual revised | Users Manual | 2003-09-30 | PDF 219.9 KB |
| Internal photos | Internal Photos | 2003-09-30 | PDF 1.2 MB |
| External photos | External Photos | 2003-09-30 | PDF 356.8 KB |
| FCC ID label sample | ID Label/Location Info | 2003-09-30 | PDF 779 KB |
| FCC IDlabel location | ID Label/Location Info | 2003-09-30 | PDF 154.6 KB |
| Test setup photos | Test Setup Photos | 2003-09-30 | PDF 631.6 KB |
| Test report revised | Test Report | 2003-09-30 | PDF 2.3 MB |
| ATCB comments | Cover Letter(s) | 2003-09-30 | PDF 25.6 KB |
| ATCB email question | Cover Letter(s) | 2003-09-30 | PDF 15.8 KB |
| POA | Cover Letter(s) | 2003-09-30 | PDF 14.5 KB |
| Request for confidentiality | Cover Letter(s) | 2003-09-30 | PDF 16 KB |
| Resposne to ATCB comments | Cover Letter(s) | 2003-09-30 | PDF 20.7 KB |
| MPE | RF Exposure Info | 2003-09-30 | PDF 18.8 KB |
| Block diagram revised Metadata only | Block Diagram | PDF 17.1 KB | |
| Schematics Metadata only | Schematics | PDF 1.5 MB | |
| Theory of operation revised Metadata only | Operational Description | PDF 11.2 KB |
Application Information
| Application ID | FHDCBkjgow6emV6zPSsCRw== |
|---|---|
| Final Action Date | 2003-09-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005011770 |
| Model | MEI915WLAN |
| Frequency Range | 902.4-927.75 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Remote Data Port |
| Responsible Party | Robert M Carney, Global Compliance Manager, bob.carney@cranepi.com.com |
| Agent | Michael Michael Michael, Washington Laboratories, Ltd., mikev@wll.com |
| Technical Contact | Gregory M Snyder, Washington Laboratories, Ltd., gregs@wll.com |
| Test Firm | Michael Violette, Washington Laboratories, Ltd., info@wll.com |
| TCB Email | hotline@americantcb.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| FHDCBkjgow6emV6zPSsCRw== | 2003-09-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 902.4-927.75 MHz | 0.8610000 | 15C |
Grants
TCB Grant - Application FHDCBkjgow6emV6zPSsCRw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 09/30/2003 Application Dated: 09/29/2003 |
| Crane Payment Innovations |
| 3222 Phoenixville Pike |
| Suite 200 |
| Malvern, PA 19355 |
| Attention: Robert Carney , Global Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QP8-MEI915WLAN |
| Name of Grantee: | Crane Payment Innovations |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Remote Data Port |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.4 - 927.75 | 0.861 |
| Power Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application FHDCBkjgow6emV6zPSsCRw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Crane Payment Innovations 3222 Phoenixville Pike Suite 200 Malvern, PA 19355 United States |
Date of Grant: 09/30/2003 Application Dated: 09/29/2003 |
| Attention: Robert Carney , Global Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QP8-MEI915WLAN |
| Name of Grantee: | Crane Payment Innovations |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Remote Data Port |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.4 - 927.75 | 0.861 |
| Power Output listed is Conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |