FCC ID QRI-BEXWW1
Status interrogation system for implantable pacemakers, defibrillators and monitors
by BIOTRONIK SE & Co. KG
Grantee Code: QRI Product Code: BEXWW1
Latest application date: 2026-01-23
FCC ID Device Details
| FCC ID | QRI-BEXWW1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | QRI |
| Product Code | BEXWW1 |
| Applicant Business | BIOTRONIK SE & Co. KG 🇩🇪 |
| Related Domains | |
| Equipment Class | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Test Firm | Eurofins Product Service GmbH |
Linked Records
Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.
| UPC / GTIN | Linked product |
|---|---|
| 4035479177638 EAN-13 · GTIN-14 04035479177638 | Status interrogation system for implantable pacemakers, defibrillators and monitors Brand: BIOTRONIK SE & Co. KG · Model: BEXWW1 Source: FCC label |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850.7-1909.3 MHz | Original Equipment | 2026-01-23 |
| 5745-5825 MHz | Original Equipment | 2026-01-23 |
| 2412-2462 MHz | Original Equipment | 2026-01-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| manual | Users Manual | 2026-02-28 | PDF 583 KB |
| um | Users Manual | 2026-02-28 | PDF 583 KB |
| in photos | Internal Photos | 2026-02-28 | PDF 104.6 KB |
| int photos | Internal Photos | 2026-02-28 | PDF 1.4 MB |
| int photos | Internal Photos | 2026-02-28 | PDF 104.6 KB |
| ex photos | External Photos | 2026-02-28 | PDF 842.3 KB |
| ext photos | External Photos | 2026-02-28 | PDF 842.3 KB |
| Label Loc | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| Label Location | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| Label Sample | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| Label sample | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| location | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| sample | ID Label/Location Info | 2026-01-23 | PDF 121.6 KB |
| test setup | Test Setup Photos | 2026-02-28 | PDF 510.5 KB |
| test setup | Test Setup Photos | 2026-02-28 | PDF 1.3 MB |
| Test Report | Test Report | 2026-01-23 | PDF 3.2 MB |
| Test Report | Test Report | 2026-01-23 | PDF 3 MB |
| Test Report | Test Report | 2026-01-23 | PDF 1.6 MB |
| Test Report | Test Report | 2026-01-23 | PDF 4.3 MB |
| Test Report | Test Report | 2026-01-23 | PDF 823.9 KB |
| Test Report | Test Report | 2026-01-23 | PDF 1.9 MB |
| Test Report | Test Report | 2026-01-23 | PDF 1.5 MB |
| Test Reports | Test Report | 2026-01-23 | PDF 1.2 MB |
| US Agent | Attestation Statements | 2026-01-23 | PDF 278.6 KB |
| cov equ | Attestation Statements | 2026-01-23 | PDF 167.5 KB |
| US Agent | Attestation Statements | PDF 176.7 KB | |
| Auth Letter | Cover Letter(s) | 2026-01-23 | PDF 160.3 KB |
| Conf Req | Cover Letter(s) | 2026-01-23 | PDF 167.7 KB |
| conf req | Cover Letter(s) | 2026-01-23 | PDF 167.7 KB |
| confidentiality | Cover Letter(s) | 2026-01-23 | PDF 167.7 KB |
| RF Exp | RF Exposure Info | 2026-01-23 | PDF 267.1 KB |
| RF Exp | RF Exposure Info | 2026-01-23 | PDF 2.8 MB |
| RF Exposure | RF Exposure Info | 2026-01-23 | PDF 2.8 MB |
| blk diagram Metadata only | Block Diagram | PDF 43.1 KB | |
| blk diagrams Metadata only | Block Diagram | PDF 43.1 KB | |
| block diag Metadata only | Block Diagram | PDF 43.1 KB | |
| diagram Metadata only | Block Diagram | PDF 43.1 KB | |
| schematics Metadata only | Schematics | PDF 2.7 MB | |
| schematics Metadata only | Schematics | PDF 295.2 KB | |
| schematics Metadata only | Schematics | PDF 799.8 KB | |
| covered equip Metadata only | Operational Description | PDF 97.7 KB | |
| description Metadata only | Operational Description | PDF 27.8 KB | |
| op descr Metadata only | Operational Description | PDF 27.8 KB | |
| cov equ | Attestation Statements | 2026-01-23 | PDF 97.7 KB |
| parts Metadata only | Parts List/Tune Up Info | PDF 115.1 KB | |
| parts Metadata only | Parts List/Tune Up Info | PDF 74.1 KB |
Application Information
| Application ID | gxnbzrO+gHm57jn8BnuoGg== |
|---|---|
| Final Action Date | 2026-01-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0008466054 |
| Model | BEXWW1 |
| Equipment Class | JAB - Part 15 Class B Digital Device |
| Device Description | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Responsible Party | Dirk Koenig, dirk.koenig@biotronik.com |
| Non-Technical Contact | Jon Brumbaugh, BIOTRONIK Inc., jon.brumbaugh@biotronik.com |
| Test Firm | Stephan Liebich, Eurofins Product Service GmbH, Stephan.Liebich@cpt.eurofinseu.com |
| TCB Email | Joerdis.Mitzloff@cpt.eurofinseu.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| gxnbzrO+gHm57jn8BnuoGg== | 2026-01-23 | Original Equipment |
| IVfmrRh4fGua3qDZosQ9lQ== | 2026-01-23 | Original Equipment |
| F3Kd0rQ5fBL7HBIpKvo6Tg== | 2026-01-23 | Original Equipment |
| 7l6fjbHK5GlPX0g/Z7HWWA== | 2026-01-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 824.2-848.8 MHz | 1.694 | 2.5 PM | 247KGXW | 22H | CC |
| 824.2-848.8 MHz | 0.482 | 2.5 PM | 249KG7W | 22H | |
| 1850.2-1909.8 MHz | 1.057 | 2.5 PM | 247KGXW | 24E | |
| 1850.2-1909.8 MHz | 0.406 | 2.5 PM | 247KG7W | 24E | |
| 1850.1-1909.9 MHz | 0.281 | 2.5 PM | 186KG7D | 24E | |
| 1850.1-1909.9 MHz | 0.276 | 2.5 PM | 129KG7D | 24E | |
| 1850.7-1909.3 MHz | 0.22 | 2.5 PM | 1M12G7D | 24E | |
| 1850.7-1909.3 MHz | 0.225 | 2.5 PM | 1M12W7D | 24E | |
| 1710.1-1754.9 MHz | 0.289 | 2.5 PM | 185KG7D | 27 | |
| 1710.1-1754.9 MHz | 0.284 | 2.5 PM | 129KG7D | 27 | |
| 1710.7-1754.3 MHz | 0.215 | 2.5 PM | 1M11G7D | 27 | |
| 1710.7-1754.3 MHz | 0.222 | 2.5 PM | 1M12W7D | 27 | |
| 824.1-848.9 MHz | 0.302 | 2.5 PM | 184KG7D | 22H | |
| 824.1-848.9 MHz | 0.288 | 2.5 PM | 127KG7D | 22H | |
| 824.7-848.3 MHz | 0.19 | 2.5 PM | 1M10G7D | 22H | |
| 824.7-848.3 MHz | 0.197 | 2.5 PM | 1M10W7D | 22H | |
| 699.1-715.9 MHz | 0.308 | 2.5 PM | 184KG7D | 27 | |
| 699.1-715.9 MHz | 0.304 | 2.5 PM | 128KG7D | 27 | |
| 699.7 MHz | 0.197 | 2.5 PM | 1M10G7D | 27 | |
| 699.7-715.3 MHz | 0.199 | 2.5 PM | 1M10W7D | 27 | |
| 777.1-786.9 MHz | 0.315 | 2.5 PM | 184KG7D | 27 | |
| 777.1-786.9 MHz | 0.306 | 2.5 PM | 128KG7D | 27 | |
| 779.5-784.5 MHz | 0.227 | 2.5 PM | 1M10G7D | 27 | |
| 779.5-784.5 MHz | 0.229 | 2.5 PM | 1M10W7D | 27 | |
| 824.1-848.9 MHz | 0.313 | 2.5 PM | 184KG7D | 22H | |
| 824.1-848.9 MHz | 0.307 | 2.5 PM | 127KG7D | 22H | |
| 824.7-848.3 MHz | 0.192 | 2.5 PM | 1M11G7D | 22H | |
| 824.7-848.3 MHz | 0.198 | 2.5 PM | 1M11W7D | 22H | |
| 698.1-715.9 MHz | 0.305 | 2.5 PM | 128KG7D | 27 | |
| 700.5-713.5 MHz | 0.195 | 2.5 PM | 1M10G7D | 27 | |
| 700.5-713.5 MHz | 0.209 | 2.5 PM | 1M10W7D | 27 | |
| 15B | CC | ||||
| 5180-5240 MHz | 0.0199 | 15E | CC | ||
| 5260-5320 MHz | 0.0194 | 15E | CC | ||
| 5500-5700 MHz | 0.0196 | 15E | CC | ||
| 5745-5825 MHz | 0.0199 | 15E | CC | ||
| 2402-2480 MHz | 0.0042 | 15C | CC | ||
| 2412-2462 MHz | 0.048 | 15C | CC |
Grants
TCB Grant - Application IVfmrRh4fGua3qDZosQ9lQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 01/23/2026 Application Dated: 01/21/2026 |
| BIOTRONIK SE & Co. KG |
| Woermannkehre 1 |
| Berlin, 12359 Germany |
| Attention: Dirk Koenig , Senior Manager Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QRI-BEXWW1 |
| Name of Grantee: | BIOTRONIK SE & Co. KG |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 22H | 824.2 - 848.8 | 1.694 | 2.5 PM | 247KGXW |
| 22H | 824.2 - 848.8 | 0.482 | 2.5 PM | 249KG7W | |
| 24E | 1850.2 - 1909.8 | 1.057 | 2.5 PM | 247KGXW | |
| 24E | 1850.2 - 1909.8 | 0.406 | 2.5 PM | 247KG7W | |
| 24E | 1850.1 - 1909.9 | 0.281 | 2.5 PM | 186KG7D | |
| 24E | 1850.1 - 1909.9 | 0.276 | 2.5 PM | 129KG7D | |
| 24E | 1850.7 - 1909.3 | 0.22 | 2.5 PM | 1M12G7D | |
| 24E | 1850.7 - 1909.3 | 0.225 | 2.5 PM | 1M12W7D | |
| 27 | 1710.1 - 1754.9 | 0.289 | 2.5 PM | 185KG7D | |
| 27 | 1710.1 - 1754.9 | 0.284 | 2.5 PM | 129KG7D | |
| 27 | 1710.7 - 1754.3 | 0.215 | 2.5 PM | 1M11G7D | |
| 27 | 1710.7 - 1754.3 | 0.222 | 2.5 PM | 1M12W7D | |
| 22H | 824.1 - 848.9 | 0.302 | 2.5 PM | 184KG7D | |
| 22H | 824.1 - 848.9 | 0.288 | 2.5 PM | 127KG7D | |
| 22H | 824.7 - 848.3 | 0.19 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.197 | 2.5 PM | 1M10W7D | |
| 27 | 699.1 - 715.9 | 0.308 | 2.5 PM | 184KG7D | |
| 27 | 699.1 - 715.9 | 0.304 | 2.5 PM | 128KG7D | |
| 27 | 699.7 - 699.7 | 0.197 | 2.5 PM | 1M10G7D | |
| 27 | 699.7 - 715.3 | 0.199 | 2.5 PM | 1M10W7D | |
| 27 | 777.1 - 786.9 | 0.315 | 2.5 PM | 184KG7D | |
| 27 | 777.1 - 786.9 | 0.306 | 2.5 PM | 128KG7D | |
| 27 | 779.5 - 784.5 | 0.227 | 2.5 PM | 1M10G7D | |
| 27 | 779.5 - 784.5 | 0.229 | 2.5 PM | 1M10W7D | |
| 22H | 824.1 - 848.9 | 0.313 | 2.5 PM | 184KG7D | |
| 22H | 824.1 - 848.9 | 0.307 | 2.5 PM | 127KG7D | |
| 22H | 824.7 - 848.3 | 0.192 | 2.5 PM | 1M11G7D | |
| 22H | 824.7 - 848.3 | 0.198 | 2.5 PM | 1M11W7D | |
| 27 | 698.1 - 715.9 | 0.305 | 2.5 PM | 128KG7D | |
| 27 | 700.5 - 713.5 | 0.195 | 2.5 PM | 1M10G7D | |
| 27 | 700.5 - 713.5 | 0.209 | 2.5 PM | 1M10W7D |
| Output power listed is conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. The highest reported SAR for head (or body) and extremity (wrist) exposure conditions are 0.50 W/kg and 1.50 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application gxnbzrO+gHm57jn8BnuoGg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 01/23/2026 Application Dated: 01/20/2026 |
| BIOTRONIK SE & Co. KG |
| Woermannkehre 1 |
| Berlin, 12359 Germany |
| Attention: Dirk Koenig , Senior Manager Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QRI-BEXWW1 |
| Name of Grantee: | BIOTRONIK SE & Co. KG |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application F3Kd0rQ5fBL7HBIpKvo6Tg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 01/23/2026 Application Dated: 01/21/2026 |
| BIOTRONIK SE & Co. KG |
| Woermannkehre 1 |
| Berlin, 12359 Germany |
| Attention: Dirk Koenig , Senior Manager Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QRI-BEXWW1 |
| Name of Grantee: | BIOTRONIK SE & Co. KG |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0199 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0194 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.0196 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0199 |
| This device supports 20 and 40 MHz modes. The highest reported SAR for head (or body) and extremity (wrist) exposure conditions are 0.50 W/kg and 1.50 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application 7l6fjbHK5GlPX0g/Z7HWWA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 01/23/2026 Application Dated: 01/20/2026 |
| BIOTRONIK SE & Co. KG |
| Woermannkehre 1 |
| Berlin, 12359 Germany |
| Attention: Dirk Koenig , Senior Manager Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QRI-BEXWW1 |
| Name of Grantee: | BIOTRONIK SE & Co. KG |
| Equipment Class: | Digital Transmission System |
| Notes: | Status interrogation system for implantable pacemakers, defibrillators and monitors |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0042 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.048 |
| Output power listed is conducted. This device supports 20 and 40 MHz modes. The highest reported SAR for head (or body) and extremity (wrist) exposure conditions are 0.50 W/kg and 1.50 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |