FCC ID QZC-RX9
900 MHz Automated Meter Reading System Transmitter
by Elster Solutions, LLC
Grantee Code: QZC Product Code: RX9
Latest application date: 2005-08-23
FCC ID Device Details
| FCC ID | QZC-RX9 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | QZC |
| Product Code | RX9 |
| Applicant Business | Elster Solutions, LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | 900 MHz Automated Meter Reading System Transmitter |
| Test Firm | TUV Rheinland of North America |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 902-915 MHz | Class II permissive change or modification of presently authorized equipment | 2005-08-23 |
| 902-915 MHz | Original Equipment | 2003-06-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Installation Manual | Users Manual | 2003-06-11 | PDF 68.5 KB |
| Internal Photos | Internal Photos | 2005-08-23 | PDF 247.3 KB |
| Internal photos | Internal Photos | 2003-06-11 | PDF 1.1 MB |
| External Photos | External Photos | 2003-06-11 | PDF 269.1 KB |
| Label | ID Label/Location Info | 2003-06-11 | PDF 73.7 KB |
| Label Location | ID Label/Location Info | 2003-06-11 | PDF 73.7 KB |
| Test Setup Photos | Test Setup Photos | 2003-06-11 | PDF 290.1 KB |
| Test Report | Test Report | 2005-08-23 | PDF 971.5 KB |
| Test Report | Test Report | 2003-06-11 | PDF 1.2 MB |
| Change Description | Cover Letter(s) | 2005-08-23 | PDF 63.9 KB |
| Confidentiality Request | Cover Letter(s) | 2005-08-23 | PDF 26 KB |
| Agency and antidrug statement | Cover Letter(s) | 2003-06-11 | PDF 231.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 20.1 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 12.2 KB | |
| Schematic Metadata only | Schematics | PDF 390.6 KB | |
| Schematic Metadata only | Schematics | PDF 398.2 KB | |
| Operational Description Metadata only | Operational Description | PDF 53.3 KB | |
| Operational Description Metadata only | Operational Description | PDF 38 KB |
Application Information
| Application ID | GGu8Q00UbCCE81e2AzVuoQ== |
|---|---|
| Final Action Date | 2005-08-23 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0008634834 |
| Model | RX9 |
| Frequency Range | 902-915 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | 900 MHz Automated Meter Reading System Transmitter |
| Responsible Party | Charles - Greene, RF Wireless Engineer, Charles.Greene@Honeywell.com |
| Technical Contact | Robert T Mason, Elster Electricity, LLC, robert.t.mason@us.elster.com |
| Non-Technical Contact | Michelle M Jenny, Elster Electricity, LLC, michelle.m.jenny@us.elster.com |
| Test Firm | Michael Moranha, TUV Rheinland of North America, mmoranha@us.tuv.com |
| TCB Email | tdwyer@us.tuv.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change Power listed is conducted. Maximum radiated power is 0.9 W EIRP. For fixed indoor or outdoor installation. Installation must provide for a minimum separation of 20 cm between radiating structure and all persons and must not be co-located or operating in conjunction with other transmitters. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| GGu8Q00UbCCE81e2AzVuoQ== | 2005-08-23 | Class II permissive change or modification of presently authorized equipment |
| tGiu2A8M41WzNPxugORN9g== | 2003-06-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application tGiu2A8M41WzNPxugORN9g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV Rheinland of North America, Inc. 1279 Quarry Lane Suite A Pleasanton, CA 94566 |
Date of Grant: 06/11/2003 Application Dated: 06/11/2003 |
| Elster Solutions, LLC |
| 208 S. Rogers Lane |
| Raleigh, NC 27610 |
| Attention: Charles Greene , RF Wireless Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QZC-RX9 |
| Name of Grantee: | Elster Solutions, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 900 MHz Automated Meter Reading System Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CE | 15C | 902.0 - 915.0 | 0.245 |
| Power listed is conducted. Maximum radiated power is 0.9 W EIRP. For fixed indoor or outdoor installation. Installation must provide for a minimum separation of 20 cm between radiating structure and all persons and must not be co-located or operating in conjunction with other transmitters. |
| CE: | This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions. |
EAS Grant - Application tGiu2A8M41WzNPxugORN9g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Elster Solutions, LLC 208 S. Rogers Lane Raleigh, NC 27610 United States |
Date of Grant: 06/11/2003 Application Dated: 06/11/2003 |
| Attention: Charles Greene , RF Wireless Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QZC-RX9 |
| Name of Grantee: | Elster Solutions, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 900 MHz Automated Meter Reading System Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CE | 15C | 902.0 - 915.0 | 0.245 |
| Power listed is conducted. Maximum radiated power is 0.9 W EIRP. For fixed indoor or outdoor installation. Installation must provide for a minimum separation of 20 cm between radiating structure and all persons and must not be co-located or operating in conjunction with other transmitters. |
| CE: | This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV Rheinland of North America, Inc. 1279 Quarry Lane Suite A Pleasanton, CA 94566 |
Date of Grant: 08/23/2005 Application Dated: 08/23/2005 |
| Elster Solutions, LLC |
| 208 S. Rogers Lane |
| Raleigh, NC 27610 |
| Attention: Charles Greene , RF Wireless Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QZC-RX9 |
| Name of Grantee: | Elster Solutions, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 900 MHz Automated Meter Reading System Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.0 - 915.0 | 0.245 |
| Class II Permissive Change Power listed is conducted. Maximum radiated power is 0.9 W EIRP. For fixed indoor or outdoor installation. Installation must provide for a minimum separation of 20 cm between radiating structure and all persons and must not be co-located or operating in conjunction with other transmitters. |
EAS Grant - Application GGu8Q00UbCCE81e2AzVuoQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Elster Solutions, LLC 208 S. Rogers Lane Raleigh, NC 27610 United States |
Date of Grant: 08/23/2005 Application Dated: 08/23/2005 |
| Attention: Charles Greene , RF Wireless Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | QZC-RX9 |
| Name of Grantee: | Elster Solutions, LLC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 900 MHz Automated Meter Reading System Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 902.0 - 915.0 | 0.245 |
| Class II Permissive Change Power listed is conducted. Maximum radiated power is 0.9 W EIRP. For fixed indoor or outdoor installation. Installation must provide for a minimum separation of 20 cm between radiating structure and all persons and must not be co-located or operating in conjunction with other transmitters. |