FCC ID QZC-RX9A

AUTOMATIC METER READING SYSTEM TRANSCEIVER

by Elster Solutions, LLC

Grantee Code: QZC   Product Code: RX9A
Latest application date: 2007-03-07

FCC ID Device Details

FCC IDQZC-RX9A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQZC
Product CodeRX9A
Applicant BusinessElster Solutions, LLC 🇺🇸
Related Domains us.elster.com
Equipment ClassAUTOMATIC METER READING SYSTEM TRANSCEIVER
Test FirmTUV Rheinland of North America

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.8-927.6 MHzOriginal Equipment2007-03-07

Exhibits

DocumentTypeAvailableFile
Installation InstructionsUsers Manual2007-03-07PDF 87.4 KB
User ManualUsers Manual2007-03-07PDF 969.6 KB
Internal PhotosInternal Photos2007-03-07PDF 1.2 MB
External PhotosExternal Photos2007-03-07PDF 135.8 KB
ID LabelID Label/Location Info2007-03-07PDF 44.3 KB
ID Label LocationID Label/Location Info2007-03-07PDF 60.6 KB
Test Setup PhotosTest Setup Photos2007-03-07PDF 1.4 MB
RF Exposure InfoRF Exposure Info2007-03-07PDF 163.3 KB
Test ReportTest Report2007-03-07PDF 3 MB
Attestation LetterAttestation Statements2007-03-07PDF 22.6 KB
Confidentiality RequestCover Letter(s)2007-03-07PDF 23.8 KB

Application Information

Application ID8YmszqV+WdDJqQSvFIL95A==
Final Action Date2007-03-07
Application PurposeOriginal Equipment
Applicant FRN0008634834
Model-RX9A
Frequency Range902.8-927.6 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionAUTOMATIC METER READING SYSTEM TRANSCEIVER
Responsible PartyJohn - Holt, Principal Engineer, john.holt@us.elster.com , 919-250-5557
Test FirmMichael Moranha, TUV Rheinland of North America, mmoranha@us.tuv.com , 919-554-0901
TCB Emailkknoerig@emcc.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
8YmszqV+WdDJqQSvFIL95A==2007-03-07Original Equipment

Equipment Authorization

FrequencyOutputEmissionRules
902.8-927.6 MHz0.2360000395KFID15C

Grants

TCB Grant - Application 8YmszqV+WdDJqQSvFIL95A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15
91364 Unterleinleiter,
Germany
Date of Grant: 03/07/2007

Application Dated: 03/07/2007
Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
 
Attention: John Holt , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RX9A
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AUTOMATIC METER READING SYSTEM TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.8  -  927.6 0.236   395KFID

Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application 8YmszqV+WdDJqQSvFIL95A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
United States
  Date of Grant: 03/07/2007

Application Dated: 03/07/2007
 
Attention: John Holt , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RX9A
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AUTOMATIC METER READING SYSTEM TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.8  -  927.6 0.236   395KFID

Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.