FCC ID QZC-RXUEV

Wireless Power Meter

by Elster Solutions, LLC

Grantee Code: QZC   Product Code: RXUEV
Latest application date: 2014-10-06

FCC ID Device Details

FCC IDQZC-RXUEV
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQZC
Product CodeRXUEV
Applicant BusinessElster Solutions, LLC 🇺🇸
Related Domains honeywell.com
Equipment ClassWireless Power Meter
Test FirmPCTEST Engineering Laboratory, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2475 MHzOriginal Equipment2014-10-06
902.8-927.6 MHzOriginal Equipment2014-10-06
824.7-848.31 MHzOriginal Equipment2014-10-06

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2015-04-04PDF 101.4 KB
Internal PhotosInternal Photos2015-04-04PDF 1.2 MB
External PhotosExternal Photos2015-04-04PDF 582.5 KB
FCC ID LabelID Label/Location Info2014-10-06PDF 461.5 KB
Test Setup PhotosTest Setup Photos2015-04-04PDF 285.8 KB
Test Setup PhotosTest Setup Photos2015-04-04PDF 230.2 KB
Test ReportTest Report2014-10-06PDF 1.7 MB
Test ReportTest Report2014-10-06PDF 1.7 MB
Test ReportTest Report2014-10-06PDF 1.7 MB
Authorization LetterAttestation Statements2014-10-06PDF 64.5 KB
Confidentiality Request LetterCover Letter(s)2014-10-06PDF 65.1 KB
Cover LetterCover Letter(s)2014-10-06PDF 128.5 KB
Short Term Confidentiality Request LetterCover Letter(s)2014-10-06PDF 64.9 KB
MPE ReportRF Exposure Info2014-10-06PDF 155.8 KB
Block Diagrams Metadata onlyBlock DiagramPDF 426.6 KB
Telit Block Diagram Metadata onlyBlock DiagramPDF 100 KB
Schematics 1 Metadata onlySchematicsPDF 397.6 KB
Schematics 2 Metadata onlySchematicsPDF 2.3 MB
Telit Schematics Metadata onlySchematicsPDF 1.2 MB
FCC KDB Correspondence Metadata onlyOperational DescriptionPDF 147.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 1.4 MB
Telit Operational Description Metadata onlyOperational DescriptionPDF 353.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 89.4 KB
Telit Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 1.4 MB

Application Information

Application IDh8wCeu952byNCTHx/WjO7A==
Final Action Date2014-10-06
Application PurposeOriginal Equipment
Applicant FRN0008634834
ModelRXUEV
Frequency Range2405-2475 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless Power Meter
Responsible PartyCharles - Greene, RF Wireless Engineer, Charles.Greene@Honeywell.com , 919-212-5018
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., tcb@pctestlab.com , 410-290-6652
Test FirmRandy Ortanez, PCTEST Engineering Laboratory, Inc., lab@pctestlab.com , 410-290-6652
TCB Emailtcb@pctestlab.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date04/04/2015
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.

Applications

Application IDDatePurpose
h8wCeu952byNCTHx/WjO7A==2014-10-06Original Equipment
LOL5vWtttvgOSMLkcaAkQg==2014-10-06Original Equipment
DHAkinFfCBmI/Yrq2jYbtw==2014-10-06Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.7-848.31 MHz0.092.5ppm1M27F9W22H
902.8-927.6 MHz0.129000015CCC
1851.25-1908.75 MHz0.2172.5ppm1M27F9W24E
2405-2475 MHz0.097000015CCC

Grants

TCB Grant - Application LOL5vWtttvgOSMLkcaAkQg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, LLC
7185 Oakland Mills Road
Columbia, MD 21046
Date of Grant: 10/06/2014

Application Dated: 10/06/2014
Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Wireless Power Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.8  -  927.6 0.129  

Power output listed is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application LOL5vWtttvgOSMLkcaAkQg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
United States
  Date of Grant: 10/06/2014

Application Dated: 10/06/2014
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Wireless Power Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.8  -  927.6 0.129  

Power output listed is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application h8wCeu952byNCTHx/WjO7A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, LLC
7185 Oakland Mills Road
Columbia, MD 21046
Date of Grant: 10/06/2014

Application Dated: 10/06/2014
Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Digital Transmission System
Notes: Wireless Power Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2475.0 0.097  

Power output listed is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application h8wCeu952byNCTHx/WjO7A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
United States
  Date of Grant: 10/06/2014

Application Dated: 10/06/2014
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: Digital Transmission System
Notes: Wireless Power Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2475.0 0.097  

Power output listed is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application DHAkinFfCBmI/Yrq2jYbtw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, LLC
7185 Oakland Mills Road
Columbia, MD 21046
Date of Grant: 10/06/2014

Application Dated: 10/06/2014
Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: PCS Licensed Transmitter
Notes: Wireless Power Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.09 2.5  PM 1M27F9W
24E 1851.25  -  1908.75 0.217 2.5  PM 1M27F9W

Power output listed is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Antenna(s) used with this device must not cause radiated power to exceed the limits specified in the FCC rules. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application DHAkinFfCBmI/Yrq2jYbtw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Elster Solutions, LLC
208 S. Rogers Lane
Raleigh, NC 27610
United States
  Date of Grant: 10/06/2014

Application Dated: 10/06/2014
 
Attention: Charles Greene , RF Wireless Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QZC-RXUEV
Name of Grantee:  Elster Solutions, LLC
Equipment Class: PCS Licensed Transmitter
Notes: Wireless Power Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.09 2.5  PM 1M27F9W
24E 1851.25  -  1908.75 0.217 2.5  PM 1M27F9W

Power output listed is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Antenna(s) used with this device must not cause radiated power to exceed the limits specified in the FCC rules. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: