FCC ID R2NSGP-1036

GSM850 / PCS1900 Dual Band Terminal Equipment

by EpiCom Co., Ltd.

Grantee Code: R2N   Product Code: SGP1036
Latest application date: 2006-09-21

FCC ID Device Details

FCC IDR2NSGP-1036
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeR2N
Product CodeSGP1036
Applicant BusinessEpiCom Co., Ltd. 🇰🇷
Related Domains epicom.co.kr
Equipment ClassGSM850 / PCS1900 Dual Band Terminal Equipment
Test FirmDT&C; Co.,

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2006-09-21

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2006-11-05PDF 346.7 KB
Internal PhotographsInternal Photos2006-11-05PDF 223.7 KB
External PhotographsExternal Photos2006-11-05PDF 135.1 KB
Label InformationID Label/Location Info2006-09-21PDF 149.1 KB
Test Setup PhotographsTest Setup Photos2006-11-05PDF 98.6 KB
RF Test ReportTest Report2006-09-21PDF 652.5 KB
SAR Test ReportRF Exposure Info2006-09-21PDF 1.2 MB
Application FormCover Letter(s)2006-09-21PDF 145.8 KB
Confidentiality RequestCover Letter(s)2006-09-21PDF 18.8 KB
Short Term Confidentiality RequestCover Letter(s)2006-09-21PDF 19.2 KB
Dipole CalibrationRF Exposure Info2006-09-21PDF 599.8 KB
Probe CalibrationRF Exposure Info2006-09-21PDF 3.7 MB
SAR Test PlotsRF Exposure Info2006-09-21PDF 734.8 KB
SAR Validation InformationRF Exposure Info2006-09-21PDF 749.6 KB
Tune Up ProcedureParts List/Tune Up Info2006-09-21PDF 40.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 51.4 KB
Schematics Metadata onlySchematicsPDF 700 KB
Operation Description Metadata onlyOperational DescriptionPDF 501.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 86.8 KB
Parts Location Metadata onlyParts List/Tune Up InfoPDF 198 KB

Application Information

Application IDWFKNHHEKItr94U5jWxjWlw==
Final Action Date2006-09-21
Application PurposeOriginal Equipment
Applicant FRN0010732899
ModelSGP-1036
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionGSM850 / PCS1900 Dual Band Terminal Equipment
Responsible PartyWoo Won Choung, Principal Engineer, wwchoung@epicom.co.kr , +82-31-714-0038
Test FirmChangho Lee, DT&C; Co.,, chlee@digitalemc.com , 82-31-321-2664
TCB Emailcertifications@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Short-Term Confidentiality Date11/05/2006
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is ERP for Part 22 and EIRP for Part 24 as measured with the antenna supplied with the unit. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. RF Exposure compliance is based on near-body SAR testing with separation distance of 2.5 cm between the antenna and the body of the user in the configuration tested. This unit is intended for desk top and wall mount use. End users must be provided with operating instructions for satisfying RF exposure compliance requirements. Highest reported body SAR values for this FCC ID are: Part 22, 0.44 W/kg; Part 24, 0.174 W/kg. The user manual must contain a statement advising the user of proper installation and use of the unit to ensure compliance with FCC radiation exposure requirements.

Applications

Application IDDatePurpose
WFKNHHEKItr94U5jWxjWlw==2006-09-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.2052.5ppm248KGXW22HBC
1850.2-1909.8 MHz0.4542.5ppm242KGXW24EBC

Grants

TCB Grant - Application WFKNHHEKItr94U5jWxjWlw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 09/21/2006

Application Dated: 09/21/2006
EpiCom Co., Ltd.
Lordland EZ Tower #511, 513, Gumi-dong, Bundang-Gu
Sungnam City, Kyunggi-Do,
South Korea
 
Attention: Woo Won Choung , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R2NSGP-1036
Name of Grantee:  EpiCom Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: GSM850 / PCS1900 Dual Band Terminal Equipment
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.205 2.5  PM 248KGXW
BC 24E 1850.2  -  1909.8 0.454 2.5  PM 242KGXW

Output power is ERP for Part 22 and EIRP for Part 24 as measured with the antenna supplied with the unit. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. RF Exposure compliance is based on near-body SAR testing with separation distance of 2.5 cm between the antenna and the body of the user in the configuration tested. This unit is intended for desk top and wall mount use. End users must be provided with operating instructions for satisfying RF exposure compliance requirements. Highest reported body SAR values for this FCC ID are: Part 22, 0.44 W/kg; Part 24, 0.174 W/kg.

The user manual must contain a statement advising the user of proper installation and use of the unit to ensure compliance with FCC radiation exposure requirements.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application WFKNHHEKItr94U5jWxjWlw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EpiCom Co., Ltd.
Lordland EZ Tower #511, 513, Gumi-dong, Bundang-Gu
Sungnam City, Kyunggi-Do,
South Korea
  Date of Grant: 09/21/2006

Application Dated: 09/21/2006
 
Attention: Woo Won Choung , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R2NSGP-1036
Name of Grantee:  EpiCom Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: GSM850 / PCS1900 Dual Band Terminal Equipment
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.205 2.5  PM 248KGXW
BC 24E 1850.2  -  1909.8 0.454 2.5  PM 242KGXW

Output power is ERP for Part 22 and EIRP for Part 24 as measured with the antenna supplied with the unit. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. RF Exposure compliance is based on near-body SAR testing with separation distance of 2.5 cm between the antenna and the body of the user in the configuration tested. This unit is intended for desk top and wall mount use. End users must be provided with operating instructions for satisfying RF exposure compliance requirements. Highest reported body SAR values for this FCC ID are: Part 22, 0.44 W/kg; Part 24, 0.174 W/kg.

The user manual must contain a statement advising the user of proper installation and use of the unit to ensure compliance with FCC radiation exposure requirements.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: