FCC ID R5C356C
CDMA 1X Digital Mobile Phone
by Huizhou TCL Mobile Communication Co., Ltd.
Grantee Code: R5C Product Code: 356C
Latest application date: 2011-10-14
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.7-848.31 MHz | Original Equipment | 2011-10-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-10-14 | PDF 332.6 KB |
| internal photos | Internal Photos | 2011-10-14 | PDF 342.5 KB |
| external photos | External Photos | 2011-10-14 | PDF 919.8 KB |
| label | ID Label/Location Info | 2011-10-14 | PDF 73.8 KB |
| test setup photos | Test Setup Photos | 2011-10-14 | PDF 110.7 KB |
| test report | Test Report | 2011-10-14 | PDF 663.5 KB |
| request for confidentiality | Cover Letter(s) | 2011-10-14 | PDF 31 KB |
| SAR report | RF Exposure Info | 2011-10-14 | PDF 2.5 MB |
Application Information
| Application ID | NyyXRAYNDT/pigFfvj7woA== |
|---|---|
| Final Action Date | 2011-10-14 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0010819100 |
| Model | 356C |
| Frequency Range | 824.7-848.31 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | CDMA 1X Digital Mobile Phone |
| Responsible Party | Jianjun Ji, Admin, jianjun.ji@tcl.com |
| Test Firm | Zhihui Liu, TA Technology (Shanghai) Co., Ltd., liuzhihui@ta-shanghai.com |
| TCB Email | brandhorst.dirk@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is ERP for part 22. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.85 W/kg; Body-worn: 0.74 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| NyyXRAYNDT/pigFfvj7woA== | 2011-10-14 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application NyyXRAYNDT/pigFfvj7woA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 10/14/2011 Application Dated: 10/14/2011 |
| Huizhou TCL Mobile Communication Co., Ltd. |
| NO.23 Zone, |
| ZhongKai High-Technology Development Zone |
| Huizhou, 518057 China |
| Attention: Jianjun Ji , Admin |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R5C356C |
| Name of Grantee: | Huizhou TCL Mobile Communication Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | CDMA 1X Digital Mobile Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.125 | 0.026 PM | 1M27F9W |
| Power listed is ERP for part 22. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.85 W/kg; Body-worn: 0.74 W/kg. |
EAS Grant - Application NyyXRAYNDT/pigFfvj7woA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Huizhou TCL Mobile Communication Co., Ltd. NO.23 Zone, ZhongKai High-Technology Development Zone Huizhou, 518057 China |
Date of Grant: 10/14/2011 Application Dated: 10/14/2011 |
| Attention: Jianjun Ji , Admin |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R5C356C |
| Name of Grantee: | Huizhou TCL Mobile Communication Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | CDMA 1X Digital Mobile Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.7 - 848.31 | 0.125 | 0.026 PM | 1M27F9W |
| Power listed is ERP for part 22. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.85 W/kg; Body-worn: 0.74 W/kg. |
| Mail To: |