FCC ID R5WNGTN541T

Tri-band GSM phone GSM850/GSM1900/DCS1800

by NewGen Telecom. Co., Ltd.

Grantee Code: R5W   Product Code: NGTN541T
Latest application date: 2004-10-26

FCC ID Device Details

FCC IDR5WNGTN541T
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeR5W
Product CodeNGTN541T
Applicant BusinessNewGen Telecom. Co., Ltd. 🇰🇷
Related Domains newgentel.com
Equipment ClassTri-band GSM phone GSM850/GSM1900/DCS1800
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2004-10-26

Exhibits

DocumentTypeAvailableFile
RF exposure warningUsers Manual2004-10-26PDF 30.6 KB
User manualUsers Manual2004-10-26PDF 543.4 KB
Internal photosInternal Photos2004-10-26PDF 1.3 MB
External photosExternal Photos2004-10-26PDF 897.7 KB
LabelID Label/Location Info2004-10-26PDF 920 KB
Test setup RFTest Setup Photos2004-10-26PDF 1.8 MB
Test setup SARTest Setup Photos2004-10-26PDF 805.5 KB
Part 15 reportTest Report2004-10-26PDF 1.3 MB
Part 22 24 plotsTest Report2004-10-26PDF 1.6 MB
Part 22 24 reportTest Report2004-10-26PDF 419.6 KB
ESN protectionAttestation Statements2004-10-26PDF 39.2 KB
Agent authorisationCover Letter(s)2004-10-26PDF 33.7 KB
Application letterCover Letter(s)2004-10-26PDF 72.4 KB
Assessment letterCover Letter(s)2004-10-26PDF 31.9 KB
ConfidentialityCover Letter(s)2004-10-26PDF 42.8 KB
Dipole calibrationRF Exposure Info2004-10-26PDF 2.7 MB
Dipole validationRF Exposure Info2004-10-26PDF 1.5 MB
Probe calibrationRF Exposure Info2004-10-26PDF 3.3 MB
SAR Test data 1RF Exposure Info2004-10-26PDF 1.4 MB
SAR Test data 2RF Exposure Info2004-10-26PDF 788 KB
SAR Test data 3RF Exposure Info2004-10-26PDF 1,015.5 KB
SAR assessmentRF Exposure Info2004-10-26PDF 82.8 KB
SAR reportRF Exposure Info2004-10-26PDF 2 MB
Block diagram Metadata onlyBlock DiagramPDF 140.7 KB
Schematics Metadata onlySchematicsPDF 2.5 MB
Operating description Metadata onlyOperational DescriptionPDF 370.4 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 169.3 KB

Application Information

Application IDYg8t0Mx9zuuhf94U6N3anQ==
Final Action Date2004-10-26
Application PurposeOriginal Equipment
Applicant FRN0010936045
ModelNGTN541T
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionTri-band GSM phone GSM850/GSM1900/DCS1800
Responsible PartyChoon-Gyum Kim, Director, cg.kim@newgentel.com , 822-596-6581
Technical ContactKi Soo Kim, Hyundai Calibration & Certification Tech Co Ltd, kisookim@hct.co.kr
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB Emailbill.wilson@babt.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP for Part 22 and EIRP for Part 24. The maximum reported body SAR was: 0.225W/kg and the maximum reported head SAR was: 1.40W/kg. SAR compliance for body worn operating conditions must be restricted to belt-clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5cm. This device contains 1800MHz GSM functions that are not operational in U.S. Territories.

Applications

Application IDDatePurpose
Yg8t0Mx9zuuhf94U6N3anQ==2004-10-26Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.7872.5ppm300KGXW22H
1850.2-1909.8 MHz0.5052.5ppm300KGXW24E

Grants

TCB Grant - Application Yg8t0Mx9zuuhf94U6N3anQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT
Octagon House, Concorde Way, Segensworth North,
Fareham, PO15 5RL
United Kingdom
Date of Grant: 10/26/2004

Application Dated: 10/26/2004
NewGen Telecom. Co., Ltd.
3rd FL. Samyoung Bldg., 106-2, Banpo-Dong,
Seoch-Gu
Seoul, 137-040
South Korea
 
Attention: Choon-Gyum Kim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R5WNGTN541T
Name of Grantee:  NewGen Telecom. Co., Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Tri-band GSM phone GSM850/GSM1900/DCS1800
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.505 2.5  PM 300KGXW
22H 824.2  -  848.8 0.787 2.5  PM 300KGXW

Output is ERP for Part 22 and EIRP for Part 24. The maximum reported body SAR was: 0.225W/kg and the maximum reported head SAR was: 1.40W/kg. SAR compliance for body worn operating conditions must be restricted to belt-clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5cm. This device contains 1800MHz GSM functions that are not operational in U.S. Territories.

EAS Grant - Application Yg8t0Mx9zuuhf94U6N3anQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

NewGen Telecom. Co., Ltd.
3rd FL. Samyoung Bldg., 106-2, Banpo-Dong, Seoch-Gu
Seoul, 137-040
South Korea
  Date of Grant: 10/26/2004

Application Dated: 10/26/2004
 
Attention: Choon-Gyum Kim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R5WNGTN541T
Name of Grantee:  NewGen Telecom. Co., Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Tri-band GSM phone GSM850/GSM1900/DCS1800
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.505 2.5  PM 300KGXW
22H 824.2  -  848.8 0.787 2.5  PM 300KGXW

Output is ERP for Part 22 and EIRP for Part 24. The maximum reported body SAR was: 0.225W/kg and the maximum reported head SAR was: 1.40W/kg. SAR compliance for body worn operating conditions must be restricted to belt-clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5cm. This device contains 1800MHz GSM functions that are not operational in U.S. Territories.