FCC ID R6N-0002

Home Wellness Sensor

by GreatCall Inc.

Grantee Code: R6N   Product Code: 0002
Latest application date: 2013-06-18

FCC ID Device Details

FCC IDR6N-0002
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeR6N
Product Code0002
Applicant BusinessGreatCall Inc. 🇺🇸
Related Domains mylively.com
Equipment ClassHome Wellness Sensor
Test FirmIntertek Testing Services NA, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2013-06-18

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2013-06-18PDF 197.3 KB
Internal PhotosInternal Photos2013-06-18PDF 1.9 MB
External PhotosExternal Photos2013-06-18PDF 371.9 KB
Label Artwork and LocationID Label/Location Info2013-06-18PDF 369.3 KB
Test Setup PhotosTest Setup Photos2013-06-18PDF 1.3 MB
Test ReportTest Report2013-06-18PDF 2.7 MB
Confidentiality RequestCover Letter(s)2013-06-18PDF 243.7 KB
Letter of AgencyCover Letter(s)2013-06-18PDF 213.2 KB
RF ExposureRF Exposure Info2013-06-18PDF 56 KB

Application Information

Application ID73TKZoEmJPQmpDpkWUpBnQ==
Final Action Date2013-06-18
Application PurposeOriginal Equipment
Applicant FRN0022201289
Model-0002
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionHome Wellness Sensor
Responsible PartyDavid Glickman, COO, david@mylively.com , 415-786-6844
Technical ContactH. Stephen Berger, TEM Consulting, LP, stephen@mylively.com , 512-864-3365
Non-Technical ContactDavid Glickman, Hamlet Inc., david@mylively.com , 415-786-6844
Test FirmPaul Coghill, Intertek Testing Services NA, Inc., paul.coghill@intertek.com , 303-405-3552
TCB EmailTCB_Admin@intertek.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe output power listed is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
73TKZoEmJPQmpDpkWUpBnQ==2013-06-18Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.002810015C

Grants

TCB Grant - Application 73TKZoEmJPQmpDpkWUpBnQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 06/18/2013

Application Dated: 06/18/2013
Lively, Inc.
683 Schofield Road
San Francisco, CA 94129
 
Attention: David Glickman , COO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R6N-0002
Name of Grantee:  Lively, Inc.
Equipment Class: Digital Transmission System
Notes: Home Wellness Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00281  

The output power listed is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of operating requirements for satisfying RF exposure compliance.

EAS Grant - Application 73TKZoEmJPQmpDpkWUpBnQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Lively, Inc.
683 Schofield Road
San Francisco, CA 94129
United States
  Date of Grant: 06/18/2013

Application Dated: 06/18/2013
 
Attention: David Glickman , COO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R6N-0002
Name of Grantee:  Lively, Inc.
Equipment Class: Digital Transmission System
Notes: Home Wellness Sensor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00281  

The output power listed is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of operating requirements for satisfying RF exposure compliance.



Mail To: