FCC ID R74TC-700U7
Two-Way Radio
by Shenzhen HYT Science &Technology; Co Ltd
Grantee Code: R74 Product Code: TC700U7
Latest application date: 2006-12-01
FCC ID Device Details
| FCC ID | R74TC-700U7 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | R74 |
| Product Code | TC700U7 |
| Applicant Business | Shenzhen HYT Science &Technology; Co Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | Two-Way Radio |
| Test Firm | Bay Area Compliance Laboratory Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-470 MHz | Class II permissive change or modification of presently authorized equipment | 2006-12-01 |
| 421-470 MHz | Original Equipment | 2006-08-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2006-08-30 | PDF 276.5 KB |
| Internal Photo | Internal Photos | 2006-10-14 | PDF 386.4 KB |
| External Photo | External Photos | 2006-08-30 | PDF 165.2 KB |
| FCC IDLabel | ID Label/Location Info | 2006-08-30 | PDF 56.5 KB |
| Test Setup Photos | Test Setup Photos | 2006-12-01 | PDF 277.9 KB |
| Test Setup Photo | Test Setup Photos | 2006-08-30 | PDF 694.7 KB |
| RF Test Report | Test Report | 2006-12-01 | PDF 188.5 KB |
| SAR Report | Test Report | 2006-08-30 | PDF 3.2 MB |
| Test REport | Test Report | 2006-08-30 | PDF 707.7 KB |
| PCII Request Letter | Cover Letter(s) | 2006-12-01 | PDF 8.1 KB |
| Confidential Lettter | Cover Letter(s) | 2006-08-30 | PDF 9.6 KB |
| Schematics Metadata only | Schematics | PDF 57.1 KB | |
| Operational Description Metadata only | Operational Description | PDF 9 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 29.4 KB | |
| Turn Up Procedure Metadata only | Parts List/Tune Up Info | PDF 22.5 KB |
Application Information
| Application ID | m2pg3z+Xqm/uErPuY8jKxA== |
|---|---|
| Final Action Date | 2006-12-01 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0008873473 |
| Model | TC-700U7 |
| Frequency Range | 400-470 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | Two-Way Radio |
| Responsible Party | Xiong Lei, rd@hyt.com.cn |
| Test Firm | John Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is ERP. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body worn: 1.96 W/kg; and Face Hold: 1.12 W/kg for 50% Duty Cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| m2pg3z+Xqm/uErPuY8jKxA== | 2006-12-01 | Class II permissive change or modification of presently authorized equipment |
| Muj3ZIxlQl+rghL7ScxGyQ== | 2006-08-30 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application Muj3ZIxlQl+rghL7ScxGyQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 08/30/2006 Application Dated: 08/30/2006 |
| Shenzhen HYT Science &Technology Co Ltd |
| R2-High-Tech Industrial Park |
| Shenzhen, China |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC-700U7 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Two Way Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 421.0 - 470.0 | 4.159 | 5.0 PM | 16K0F3E | |
| 90 | 421.0 - 470.0 | 1.0 | 2.5 PM | 11K0F3E |
| Power listed is ERP. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body worn: 1.96 W/kg; and Face Hold: 1.12 W/kg for 50% Duty Cycle. |
EAS Grant - Application Muj3ZIxlQl+rghL7ScxGyQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen HYT Science &Technology Co Ltd R2-High-Tech Industrial Park Shenzhen, China |
Date of Grant: 08/30/2006 Application Dated: 08/30/2006 |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC-700U7 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Two Way Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 421.0 - 470.0 | 4.159 | 5.0 PM | 16K0F3E | |
| 90 | 421.0 - 470.0 | 1.0 | 2.5 PM | 11K0F3E |
| Power listed is ERP. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body worn: 1.96 W/kg; and Face Hold: 1.12 W/kg for 50% Duty Cycle. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 12/01/2006 Application Dated: 12/01/2006 |
| Shenzhen HYT Science &Technology Co Ltd |
| R2-High-Tech Industrial Park |
| Shenzhen, China |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC-700U7 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Two-Way Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 400.0 - 470.0 | 4.159 | 5.0 PM | 16K0F3E | |
| 90 | 400.0 - 470.0 | 1.0 | 2.5 PM | 11K0F3E |
| Power listed is ERP. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body worn: 1.96 W/kg; and Face Hold: 1.12 W/kg for 50% Duty Cycle. |
EAS Grant - Application m2pg3z+Xqm/uErPuY8jKxA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen HYT Science &Technology Co Ltd R2-High-Tech Industrial Park Shenzhen, China |
Date of Grant: 12/01/2006 Application Dated: 12/01/2006 |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC-700U7 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Two-Way Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 400.0 - 470.0 | 4.159 | 5.0 PM | 16K0F3E | |
| 90 | 400.0 - 470.0 | 1.0 | 2.5 PM | 11K0F3E |
| Power listed is ERP. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body worn: 1.96 W/kg; and Face Hold: 1.12 W/kg for 50% Duty Cycle. |
| Mail To: |