FCC ID R74TC-700V

Two Way Radio

by Shenzhen HYT Science &Technology; Co Ltd

Grantee Code: R74   Product Code: TC700V
Latest application date: 2005-08-31

FCC ID Device Details

FCC IDR74TC-700V
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeR74
Product CodeTC700V
Applicant BusinessShenzhen HYT Science &Technology; Co Ltd 🇨🇳
Related Domains hyt.com.cn
Equipment ClassTwo Way Radio
Test FirmBay Area Compliance Laboratory Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzOriginal Equipment2005-08-31

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2005-08-31PDF 457.6 KB
Internal PhotosInternal Photos2005-10-15PDF 355.5 KB
External PhotosExternal Photos2005-08-31PDF 132.6 KB
FCC ID Label InformationID Label/Location Info2005-08-31PDF 56.1 KB
Test ReportTest Report2005-08-31PDF 1 MB
Confidentiality Request LetterCover Letter(s)2005-08-31PDF 32.1 KB
Tune Up ProcedureParts List/Tune Up Info2005-08-31PDF 43.1 KB
Schematics Metadata onlySchematicsPDF 107 KB
Operational Description Metadata onlyOperational DescriptionPDF 75.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 114.1 KB

Application Information

Application ID7tpDPMXGQJJrhdv0OFHXCA==
Final Action Date2005-08-31
Application PurposeOriginal Equipment
Applicant FRN0008873473
ModelTC-700V
Frequency Range136-174 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionTwo Way Radio
Responsible PartyXiong Lei, rd@hyt.com.cn , 0755-26972999
Test FirmJohn Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com , 08675533320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Short-Term Confidentiality Date10/15/2005
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information

Applications

Application IDDatePurpose
7tpDPMXGQJJrhdv0OFHXCA==2005-08-31Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
136-174 MHz5.262.5ppm11K0F3E9
136-174 MHz5.262.5ppm14K0F3E9
136-174 MHz5.262.5ppm16K0F3E9

Grants

TCB Grant - Application 7tpDPMXGQJJrhdv0OFHXCA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/31/2005

Application Dated: 08/31/2005
Shenzhen HYT Science &Technology Co Ltd
R2-High-Tech Industrial Park
Shenzhen,
China
 
Attention: Xiong Lei

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R74TC-700V
Name of Grantee:  Shenzhen HYT Science &Technology Co Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Two Way Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 136.0  -  174.0 5.26 2.5  PM 11K0F3E
90 136.0  -  174.0 5.26 2.5  PM 14K0F3E
90 136.0  -  174.0 5.26 2.5  PM 16K0F3E

Output Power is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information

EAS Grant - Application 7tpDPMXGQJJrhdv0OFHXCA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen HYT Science &Technology Co Ltd
R2-High-Tech Industrial Park
Shenzhen,
China
  Date of Grant: 08/31/2005

Application Dated: 08/31/2005
 
Attention: Xiong Lei

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R74TC-700V
Name of Grantee:  Shenzhen HYT Science &Technology Co Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Two Way Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 136.0  -  174.0 5.26 2.5  PM 11K0F3E
90 136.0  -  174.0 5.26 2.5  PM 14K0F3E
90 136.0  -  174.0 5.26 2.5  PM 16K0F3E

Output Power is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information



Mail To: