FCC ID R74TC3000U0
FM Handheld Transceiver
by Shenzhen HYT Science &Technology; Co Ltd
Grantee Code: R74 Product Code: TC3000U0
Latest application date: 2007-05-21
FCC ID Device Details
| FCC ID | R74TC3000U0 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | R74 |
| Product Code | TC3000U0 |
| Applicant Business | Shenzhen HYT Science &Technology; Co Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | FM Handheld Transceiver |
| Test Firm | Shenzhen Huatongwei International Insp. Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-406 MHz | Original Equipment | 2007-05-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Operational Description | Operational Description | 2007-05-21 | PDF 52.2 KB |
| Users Manual | Users Manual | 2007-05-21 | PDF 374.2 KB |
| Internal Photos | Internal Photos | 2007-05-21 | PDF 211.5 KB |
| External Photos | External Photos | 2007-05-21 | PDF 388.3 KB |
| ID Label Info | ID Label/Location Info | 2007-05-21 | PDF 170.7 KB |
| Block Diagram | Block Diagram | 2007-05-21 | PDF 196.3 KB |
| Schematics | Schematics | 2007-05-21 | PDF 741.5 KB |
| Test Setup Photos | Test Setup Photos | 2007-05-21 | PDF 195.9 KB |
| SAR Test Report I | RF Exposure Info | 2007-05-21 | PDF 3.2 MB |
| SAR Test Report II | RF Exposure Info | 2007-05-21 | PDF 1.6 MB |
| Test Report | Test Report | 2007-05-21 | PDF 2.6 MB |
| Parts List | Parts List/Tune Up Info | 2007-05-21 | PDF 252.3 KB |
Application Information
| Application ID | gqU6DZp/QFqBYbVVeHR/hA== |
|---|---|
| Final Action Date | 2007-05-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0008873473 |
| Model | TC3000U0 |
| Frequency Range | 400-406 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | FM Handheld Transceiver |
| Responsible Party | Xiong Lei, rd@hyt.com.cn |
| Test Firm | Moffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn |
| TCB Email | kknoerig@emcc.de |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is rated conducted. Maximum measured output power is 4.295 Watts. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clip and accessory configurations that have no metallic component in the assembly and that provide a minimum of 1.5cm separation between the device, including its antenna, and the user’s body. The highest reported SAR values are: Head: 3.752 W/kg; Body-worn: 5.199 W/kg accounting for a 100% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| gqU6DZp/QFqBYbVVeHR/hA== | 2007-05-21 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application gqU6DZp/QFqBYbVVeHR/hA==
TYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
| TCB |
GRANT OF EQUIPMENT
AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15 91364 Unterleinleiter, Germany |
Date of Grant: 05/21/2007
Application Dated: 05/21/2007 |
| Shenzhen HYT Science &Technology Co Ltd |
| R2-High-Tech Industrial Park |
|
Shenzhen,
China |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC3000U0 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | FM Handheld Transceiver |
| Grant Notes | FCC Rule Parts |
Frequency
Range (MHZ) |
Output
Watts |
Frequency
Tolerance |
Emission
Designator |
| 90 | 400.0 - 406.0 | 4.0 | 1.4 PM | 16K0F3E | |
| 90 | 400.0 - 406.0 | 4.0 | 1.4 PM | 11K0F3E | |
| 90 | 406.1 - 470.0 | 4.0 | 1.4 PM | 16K0F3E | |
| 90 | 406.1 - 470.0 | 4.0 | 1.4 PM | 11K0F3E |
| Power output listed is rated conducted. Maximum measured output power is 4.295 Watts. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clip and accessory configurations that have no metallic component in the assembly and that provide a minimum of 1.5cm separation between the device, including its antenna, and the users body. The highest reported SAR values are: Head: 3.752 W/kg; Body-worn: 5.199 W/kg accounting for a 100% duty cycle. |
EAS Grant - Application gqU6DZp/QFqBYbVVeHR/hA==
TYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
| COPY |
FEDERAL COMMUNICATIONS
COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen HYT Science &Technology Co Ltd
R2-High-Tech Industrial Park Shenzhen, China |
Date of Grant: 05/21/2007
Application Dated: 05/21/2007 |
| Attention: Xiong Lei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | R74TC3000U0 |
| Name of Grantee: | Shenzhen HYT Science &Technology Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | FM Handheld Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts |
Frequency
Range (MHZ) |
Output
Watts |
Frequency
Tolerance |
Emission
Designator |
| 90 | 400.0 - 406.0 | 4.0 | 1.4 PM | 16K0F3E | |
| 90 | 400.0 - 406.0 | 4.0 | 1.4 PM | 11K0F3E | |
| 90 | 406.1 - 470.0 | 4.0 | 1.4 PM | 16K0F3E | |
| 90 | 406.1 - 470.0 | 4.0 | 1.4 PM | 11K0F3E |
|
Power output listed is rated conducted. Maximum measured output power is 4.295 Watts. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clip and accessory configurations that have no metallic component in the assembly and that provide a minimum of 1.5cm separation between the device, including its antenna, and the users body. The highest reported SAR values are: Head: 3.752 W/kg; Body-worn: 5.199 W/kg accounting for a 100% duty cycle.
|
| Mail To: |
|
EA889514 |